Rinnai Arriva 752 Operation Manual Download Page 6

  

6

   |   Arriva 752 operation guide: 12219-C 03-20

About your Arriva 752

Congratulations on the purchase of your Rinnai Arriva gas fireplace. We hope you love this product 

as much as we do, and on the off chance that something does go wrong, or if you need help, we’re 

only a phone call away.

Auto overheat discharge vent

Room air return

Louvre, warm air discharge

Room air return

Burn media
Blockage indicator for filter 

and louvre blockages

Double glazed

frame window

Control panel

Remote receiver window for 

infra red remote (5 m range)

Error display

Displays error codes

Operation indicator*

Indicates operation status

Timer indicator

Indicates timer program status

On/Off button

Turns the heater on or off

Room 

air 

return

Safety devices

Your Rinnai Arriva has the following safety 

devices:
• 

flame failure sensing system

•  pressure relief
• 

overheat safety switch

•  air temperature sensor
•  thermal fuse
•  overcurrent fuse
•  spark detection

Positioning the Arriva 752

To gain maximum heating advantage from the bottom air discharge, the Arriva looks and performs 

best when installed close to the floor. If installed higher up the wall, the movement of air from the 

convection fan, depending on the room configuration could create drafts.

Power failure

If power is disrupted while the fire is operating, once power is restored, it will go into power failure 

mode

flashing zeros in the error display, and a green LED* on the control panel.

To reset the fire, press the On/Off button on the control panel twice, or use the remote control and 

press the Standby/On button once, to go into standby, and then a second time to turn the fire back 

on.

* Control panel LED colours; red = on, green = standby, green flashing = error code indication

Summary of Contents for Arriva 752

Page 1: ...Arriva 752 gas fireplace Operation guide...

Page 2: ...and serviced by an authorised person being in New Zealand a licensed gasfitter Warning Improper installation adjustment alteration service and maintenance can cause property damage personal injury or...

Page 3: ...ng 12 Error codes 14 Abnormal flame pattern 15 Installation checklist and installer details 16 Purchase details 17 Register your Ariiva 752 online 17 Limited Warranty 18 Contents Gas fires like cars r...

Page 4: ...cated immediately below a power socket outlet potential fire hazard Do not restrict warm air discharge by placing articles in front of the fire Do not post or allow children to post articles into the...

Page 5: ...Small soot deposits inside the heater or glass is normal Significant soot build up however is not normal and will require a service call Refer to the troubleshooting section for further information En...

Page 6: ...a has the following safety devices flame failure sensing system pressure relief overheat safety switch air temperature sensor thermal fuse overcurrent fuse spark detection Positioning the Arriva 752 T...

Page 7: ...ttempt to clean the filters with water Heater shut down due to filter blockages Do not wait for the blockage indicator error code 14 to come on before cleaning the filters and do not continue to use t...

Page 8: ...earth must not obscure the front face of the fire or obstruct the fire in any way including the frame around the fire TV installation above the fire The Arriva has a fan that distributes warm air from...

Page 9: ...The ignition sparker will operate as soon as a spark is sensed and gas will flow to the main burner 3 When the main burner has established the unit will automatically modulate between the burner sett...

Page 10: ...remote is not going to be used for a long time This will help avoid damage from leaking batteries After batteries are replaced the clock and timers may need to be reprogrammed Standby On Stops and op...

Page 11: ...Preheat automatically functions in conjunction with the timers The preheat function ensures the room reaches temperature by the programmed on time This is achieved by sensing the room temperature one...

Page 12: ...is to allow the appliance to warm up helping avoid cold drafts Smoke or strange smells when operating after installation This is caused by grease oil or dust within the appliance This will stop after...

Page 13: ...Fire not plugged in properly or turned off Plug in power cord or press the On Off button on the control panel Mains power failure Use power reset procedure refer p 6 Arriva stops during operation Main...

Page 14: ...once fro standby then a second time to turn the fire on 11 Ignition failure Check gas supply is turned on switch heater to standby and then on again If ignition failure continues a service call is re...

Page 15: ...or shifting of burn media There are some warning signs that could indicate a problem Unusual smell from the appliance Continued difficulty or delay in establishing a flame Either very short or very l...

Page 16: ...ble location clearances mantels surrounds etc F Rinnai flue system installed and tested to ensure effective draw F Gas pressure checked and set according to the data plate F Burn media installed as pe...

Page 17: ...dress Date of purchase Product details Record your purchase details below Register your fire online at www rinnai co nz register You ll need to know the model and also the serial number shown on the s...

Page 18: ...ees the availability of repair facilities and spare parts for the express warranty period recorded in the table above This warranty does not limit any consumer rights or guarantees that may apply unde...

Page 19: ...arge and cost of parts if required 1 Accidental damage and acts of God 2 Failure due to abuse or misuse improper maintenance or improper storage 3 Failure due to incorrect or unauthorised installation...

Page 20: ...Arriva 752 operation guide 12219 C Serial number Rinnai co nz 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz...

Reviews: