General
2
Safety
3
Outdoor Areas
4
Pre-Assembly
5
Assembly
6-11
Inspection
12-13
Accessory Assembly
13
Operation
14-16
Fault Finding
17
Maintenance
18-20
Parts Diagram / List
22-23
TABLE OF CONTENTS
Barbecues must be used in accordance with the installation
requirements of your local gas supply authority, and the
appropriate installation standard AS5601/AG601.
Barbecues for use with bottled gas are labelled
‘Universal
LPG’
. Barbecues for use with natural gas are labelled
‘Natural
Gas’
and must be installed by a qualified person. Check the
gas type sticker attached to the barbecue. Check that the label
matches the gas type to be used.
GAS INSTALLATION CODES
FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN A
FIRE OR EXPLOSION WHICH COULD
CAUSE SERIOUS BODILY INJURY,
DEATH OR PROPERTY DAMAGE.
ACCESSIBLE PARTS MAY BE VERY HOT.
KEEP YOUNG CHILDREN AWAY.
ANY MODIFICATION OF THIS
APPLIANCE MAY BE DANGEROUS.
DO NOT MOVE THIS APPLIANCE
DURING USE.
TURN OFF THE GAS SUPPLY AT THE
GAS CYLINDER AFTER USE.
READ THE INSTRUCTIONS BEFORE
USING THE APPLIANCE.
PARTS SEALED BY THE
MANUFACTURER MUST NOT BE
MANIPULATED.
THIS BARBECUE IS ONLY TO BE USED
OUTDOORS.
NEVER OPERATE THIS BARBECUE
WITHOUT A REGULATOR.
Appliance specifications can be found on the data label
attached to the rear panel of the barbecue body.
SPECIFICATIONS
G
E
N
E
R
A
L
2
2
Purchased from
Date purchased
Serial No.
NOTE: Sales docket must be kept as proof of purchase date.
FOR CUSTOMER REFERENCE
(Record and file in a safe place)
This barbecue is also certified for use on natural gas. It must be
converted and installed by a qualified person if not provided in
the correct condition for use on natural gas. Contact your place
of purchase for advice in relation to using your barbecue on
natural gas if not already provided in natural gas specification.
NATURAL GAS INSTALLATION
The regulator and hose assembly supplied with the barbecue is
suitable for use with bottled gas – POL connection.
A gas regulator adjusted to have an outlet pressure of 2.75
kPa is supplied for connection to the gas cylinder. The regulator
and hose assembly supplied with the appliance must be used.
Replacement regulator and hose assemblies must be those
specified by the appliance manufacturer.
When connecting the hose and regulator assembly to the
gas cylinder, take care to avoid unnecessary twisting of the
flexible hose. After the assembly has been secured, turn on the
gas and check for leaks by brushing a soap and water solution
over all visible and accessible gas line connections. The presence
of bubbles will indicate a gas escape.
DO NOT TEST FOR GAS
ESCAPES WITH AN OPEN FLAME.
If you are unable to correct the leak by tightening the
connection, turn off the gas and contact your place of purchase
immediately.
Always ensure the appliance is kept away from flammable
materials and the gas cylinder clear of any heat source.
When changing over from an empty gas cylinder to a full
one, make sure this procedure is carried out in a flame free
atmosphere.
Inspect the gas hose when replacing the gas cylinder or
once a year whichever is more frequent. If the hose is cracked,
cut, abraded or damaged in any way, the appliance must not be
operated. The hose must be replaced if damaged or when
statutory conditions require it. Contact your place of purchase
if uncertain.
The POL fitting of the hose and regulator should be
disconnected from the gas cylinder valve when the outdoor
appliance is not in use.
HOSE AND REGULATOR SAFETY
Height – hood closed 1235 mm, hood open 1605 mm
Width – 1840 mm
Depth – hood closed 660 mm, hood open 785 mm
Openings at the rear and sides of the appliance provide air
for combustion, and must not be obstructed.
Minimum clearances from combustible materials must be
maintained: top and rear – 800 mm, sides – 250 mm, bottom of
firebox – 300 mm
(inbuilt model)
.
DIMENSIONS AND CLEARANCES
5
/
8
"-18 UNF (
3
/
8
" SAE FLARE).
HOSE CONNECTIONS