background image

 

 

Owner’s Operation and Installation Manual for the 

 

Rinnai Outdoor Fireplace 

4500 Series 

INSTALLER:   Leave this manual with the appliance. 
CONSUMER:  Retain this manual for future reference. 

—  Do not store or use gasoline or other flammable vapors and 

liquids in the vicinity of this or any other appliance. 

 
—  WHAT TO DO IF YOU SMELL GAS 
 

• 

Do not try to light any appliance. 

• 

Do not touch any electrical switch; do not use any phone in 
your building. 

• 

Immediately call your gas supplier from a neighbor’s phone.  
Follow the gas supplier’s instructions. 

• 

If you cannot reach your gas supplier, call the fire 
department. 

 
—  Installation and service must be performed by a qualified 

installer, service agency or the gas supplier. 

WARNING: If the information in these instructions is not 
followed exactly, a fire or explosion may result causing 
property damage, personal injury or death. 

Table of Contents ........... 2 

Safety Information .......... 2 

Operating Instructions .... 8 

Care and Maintenance ... 9 

Installation Instructions ... 10 

Parts List ........................ 21 

Consumer Support ......... 26 

French Version ............... 28 

WARNING:  Improper installation, adjustment, alteration, service or maintenance can cause 

injury or property damage.  Read the installation, operating, and maintenance 
instructions thoroughly before installing or servicing this equipment. 

WARNING:  For Outdoor Use Only 

Summary of Contents for 4500

Page 1: ...cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Table of Contents 2 Safety Information 2 Operating Instructions 8 Care and Maintenance 9...

Page 2: ...sembly in an Open 1 sided or 2 sided Installation 15 17 Installing Burn Media 18 Complete Gas Connection 19 Guidelines for Cladding and Finishes 20 Parts List 21 25 Consumer Support 26 27 Table of Contents Consumer Safety Information Safety Definitions This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others Indicates an imminently hazardous ...

Page 3: ...s This appliance must not be used for any other purpose than heating Do not use this appliance to prepare food The appliance including burner assembly if used alone must be secured into or onto a permanent fixture Any materials or objects that are near this appliance when it is in operation may be subjected to radiant heat and could sustain damage Any guard or other protective device removed for s...

Page 4: ... and replaceable fixed pilot orifice for conversion to natural gas Pilot assembly also contains a pilot ignition electrode and thermocouple for flame failure Piping Burner is supplied through an aluminum pipe from the gas control to the burner orifice block Pilot burner is supplied gas by an aluminum pipe directly from the gas control Pressure Test Point Incorporated into the main burner orifice b...

Page 5: ... With Fascia and Doors Dimensions 42 52 in 1080 mm 3 00 in 76 mm 4 76 in 121 mm 15 75 in 400 mm 46 06 in 1170 mm 18 50 in 470 mm 21 65 in 550 mm 47 44 in 1205 mm 19 21 in 488 mm for 1 sided Frame is 1 57 in 40 mm wide 0 67 in 17 mm deep 19 88 in 505 mm for 2 sided 23 03 585 ...

Page 6: ...dels must be used if installation is into a combustible enclosure It consists of a construction with an open front pictured or with open front and back see through Body Assembly with Glass Doors The body assembly has optional tempered glass double bi fold doors to reduce the effects of wind or rain on the burner The appliance can operate with the doors open or closed The appliance operates with th...

Page 7: ...ance and so is only suitable for installations where a cabinet or body assembly has been installed Sample Installations Components Needed Freestanding ROF4500 Open 1 Sided Cabinet ROF4501 Open 2 Sided Cabinet ROF4502 Non combustible enclosed masonry Burner Assembly LPG ROF4500 1 Sided Burner Body Assembly LPG ROF4501 1 2 Sided Burner Body Assembly LPG ROF4502 1 Glass Bi fold Door Assembly R2612 2 ...

Page 8: ...ing to pilot Look for the pilot flame 3 Hold down for an additional 5 seconds to activate the flame and then release NOTE Steps 1 and 2 may need to be repeated several times to ignite the fire This will vary according to the gas being used 4 Once the heater is on turn the knob to the high setting for a period of time in order to establish a flame pattern You can modulate the flame by adjusting bet...

Page 9: ...place has a distinct flame pattern This should look the same every time after an initial warm up period of approximately 30 minutes Abnormal flame pattern can indicate a problem with your appliance Blocked gas orifices or burn media that have shifted can produce an abnormal flame pattern There are some warning signs that could indicate a problem Unusual smell from the appliance Continued difficult...

Page 10: ...k for Damage Check for damage Do not install any damaged items Check that you have all the components you require Read Instructions Before using the appliance please read the entire manual to ensure correct use Failure to follow these instructions could cause a malfunction of the appliance This could result in death serious injury and or property damage Failure to follow these instructions may als...

Page 11: ...e inches 64 5 sq cm If ventilation openings at floor level are in a side wall there shall be at least two openings The bottom of the openings shall be at floor level and the upper edge no more than 5 inches 127 mm above the floor The openings shall be equally sized spaced at 180 degrees and unobstructed 3 Every opening shall have minimum dimensions so as to permit the entrance of a 1 8 inch 3 2 mm...

Page 12: ... of the sides is 2 x 8 x 15 2 x 8 x 10 400 square feet Therefore this rule is met because 120 400 0 3 The open side equals 30 of the total area of the sides With walls on all sides but at least one permanent opening at ground level and no overhead cover Within a partial enclosure that includes an overhead cover and no more than two walls at least 2 sides of the enclosure are open Within a partial ...

Page 13: ...s 19 68 in 500 mm From an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation Mechanical Air Inlet 78 74 in 2000 mm For example an air conditioning unit Body Assembly open 1 sided or 2 sided Freestanding CANNOT be installed above the unit if any part of the surround is made of combustible material If installing into a no...

Page 14: ...Complete Gas Connection This is common to all installations Refer to these sections in the manual Prepare a gas connection opening underneath the gas supply access position Ensure the opening is large enough for the flexible connection to fit through Minimum Dimensions 21 85 in 555 mm 46 26 in 1175 mm 18 50 in 470 mm A B C 17 91 in 455 mm 17 91 in 455 mm 19 68 in 500 mm 8 27 in 210 mm 10 24 in 260...

Page 15: ...ove Side Below Behind 1 2 in 30 mm Non combustible cladding is required over the entire frame Includes 1 in 25 mm side clearances Includes cladding for 1 sided unit this includes cladding on one side only Attach Metal Lintel and Angled Clearance Brackets Metal Lintel Designed to sit above the appliance and replace combustible framing in areas above the appliance To install 1 Take out and undo 4 fa...

Page 16: ... adequate horizon tally and vertically 2 Screw clearance brackets to the inner side of stud 3 Ensure that the flat face of the clearance bracket is facing out as shown above Clad Surround Refer to the section Guidelines for Cladding and Finishes 48 3 in 1225 mm minimum cabinet non combustible cladding clearance bracket timber stud 46 5 in 1180 mm minimum 47 0 in 1195 mm maximum 19 7 in 500 mm mini...

Page 17: ...these sections in the manual Attach Mounting Brackets The mounting brackets have 3 functions 1 to secure cabinet to enclosure 2 to act as seismic restraints bottom brackets only 3 and to connect the outer steel frame to the cabinet Fasten the 4 frame mounting brackets using the M5 button head bolts to the body assembly Install Steel Frame 1 There is a top and bottom to the steel frame with the top...

Page 18: ... the bottom of the granite trims Not all the pumice will be needed as more has been supplied than is necessary Using all the small quartz provide place a single layer of small quartz stones covering the entire top of the pumice Place the 14 pieces of large quartz stones on top of the small quartz Do not stack the large stones on large stones Layer 2 Single Layer of Small Quartz Layer 3 Single Laye...

Page 19: ...tightly installed and must not be stored in a building garage or any other enclosed area The cylinder supply system must be arranged for vapor withdrawal The cylinder must be installed in an upright position The gas must be turned off at the cylinder when the appliance is not in use The cylinder must include a collar to protect the cylinder valve 1 Push the flexible connection through the base of ...

Page 20: ...bly installed 302 F 150 C without the door assembly installed 212 F 100 C Cladding materials shall be non combustible and suitable for an outdoor environment If you are installing a door assembly a heat rated material such as calcium silicate board must be above the fire Such materials require installation and sealing in accordance with the supplier specification Rinnai accepts no responsibility f...

Page 21: ...COUPLE NUT 16 1 7903 SPACER THERMOCOUPLE PILOT 17 1 11298 ELBOW 3 8 BSPTx3 8 BSPT 19 12 9065 SCREW M4X10 PAN PHIL ST ST 304 Item No QTY Part No Description 21 1 11203 THERMOCOUPLE OUTDOOR FIRE 22 1 6749 RUBBER GROMMET IMG010 23 1 7132 RUBBER GROMMET P CORD IMG030 24 1 11297 REDUSING BUSH 3 8BSPP F 1 2BSPT M 25 1 11202 REGULATOR LPG 26 1 11272 REGULATOR ANTI TWIST BRKT 27 1 5074 REDUCING FLARE 3 8X...

Page 22: ...ND 8 1 11331 CONTROL KNOB ASSY 9 1 11220 BURNER BRACKET 10 1 11237 PRIMARY AIR COVER 11 1 11225 PRIMARY AIR SHIELD Item No QTY Part No Description 12 1 11222 PILOT COVER TOP 13 1 11223 PANEL PILOT COVER ASSEMBLY 14 1 11271 PANEL CONTROL COVER 15 6 11228 GRANITE 272X20mm 16 2 11229 GRANITE 192X111mm 17 1 11329 WEATHER SHIELD ASSY 18 12 9006 SCREW BUTTON SOCKET 304 M5X12 19 9 9324 RIVET POP PLAIN 73...

Page 23: ... 11332 TOP PANEL ASSY ROF4501 3 0 1 11342 TOP PANEL ASSY ROF4502 4 1 0 11235 PANEL BODY REAR RADIUS ROF4501 5 2 2 11236 TRANSPORT BRACKET 6 2 4 11238 BODY CORNER BRACKET 7 4 8 11267 FASCIA MOUNTING BRKT 8 1 2 R2615 FRAME TRIM SS 40MM 9 1 2 11253 LOUVRE TOP 10 1 2 11214 TOP FLASHING 11 1 2 R2629 HEADER KIT 12 4 4 11268 INSTALLATION SPACER BRKT Quantity ...

Page 24: ...500 The complete assembly can be purchased as Kit R2615 Frame Trim SS Item No Quantity Part No Description 1 1 11264 FASCIA TOP 2 1 11266 FASCIA BOTTOM 3 2 11265 FASCIA VERTICAL 4 8 9065 SCREW M4x10 PAN PHIL ST ST 304 Parts List ...

Page 25: ...Rinnai Corporation ROF4500 25 Parts List Item No Quantity Part No Description 1 1 11335 GLASS DOOR ASSY RIGHT ROF4500 2 1 11334 GLASS DOOR ASSY LEFT ROF4500 3 1 11336 DOOR SWING CATCH SET ROF4500 ...

Page 26: ...ials or workmanship as set forth as follows All repair parts must be genuine Rinnai parts All repairs or replacements must be performed by an individual or servicing company that has been authorized by Rinnai The installer is responsible for your heater s correct installation Please complete the information below to keep for your records Purchased from _____________________________________________...

Page 27: ... cover any failures or operating difficulties due to the following accident abuse or misuse alteration misapplication force majeure improper installation such as but not limited to condensate damage improper venting incorrect gas type or incorrect gas pressure improper conversion including conversions for inventory adjustment improper maintenance any other causes other than defects in materials or...

Page 28: ...u de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez à aucun interrupteur ne pas vous servir des téléphones se trouvant dans le bâtiment Appelez immédiatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur appelez le service des incendies L installation et l entr...

Page 29: ...r signaler des pratiques non sûres DANGER ATTENTION AVERTISSEMENT Informations pour la sécurité du consommateur Définitions de sécurité 29 Comportements et pratiques de sécurité 30 Dispositifs de sécurité 30 Spécifications 31 Dépannage 31 Dimensions 32 Caractéristiques d Assemblée 33 Applications d installation 34 Instructions d utilisation Avant de commencer l appareil 35 Opérer l appareil 35 Ent...

Page 30: ...le gaz de propane Cet appareil ne doit pas n être employé pour aucun autre but que le chauffage N employez pas cet appareil pour préparer la nourriture L appareil brûleur y compris si seul utilisé doit être fixé dans ou sur un montage permanent Tous les matériaux ou objets qui sont près de cet appareil quand ils sont en fonction peuvent être soumis à la chaleur radiante et pourraient soutenir des ...

Page 31: ...te SIT le pilote simple d orifice avec l aération fixe et l orifice pilote fixe remplaçable pour la conversion en gaz naturel L assemblée pilote contient également une électrode et un thermocouple pilotes d allumage pour l échec de flamme Tuyauterie Le brûleur est fourni par une pipe en aluminium à partir de la commande de gaz au bloc d orifice de brûleur Le brûleur pilote est gaz assuré par une p...

Page 32: ...in 1170 mm 18 50 in 470 mm 21 65 in 550 mm 47 44 in 1205 mm 19 21 in 488 mm for 1 sided Frame is 1 57 in 40 mm wide 0 67 in 17 mm deep 19 88 in 505 mm for 2 sided 23 03 585 Dimensions Dimensions de brûleur Dimensions de corps Avec des Aimensions de Fasce et de Porte La vue est 15 7 40 au loin 0 67 17 profondément 19 21 488 pour 1 dégrossi 19 88 505 pour 2 dégrossis ...

Page 33: ...u fermées L appareil fonctionne avec Bi plient des portes avec de l air étant dessiné dans la chambre de combustion par la moitié inférieure de l avant ouvert et expulsé dehors le dessus ou par les auvents supérieurs des portes de verre Consoles d armature en acier Les modules en acier de console d armature sont disponibles qui peuvent réduire le temps d installation et fournir la flexibilité de c...

Page 34: ...eil et est ainsi seulement appropriée aux installations où un coffret ou le montage de corps a été installé Installations témoin Les composants ont eu besoin Libre ROF4500 1 a dégrossi ROF4501 2 dégrossis ROF4502 Maçonnerie incluse non combustible Assemblée de brûleur LPG ROF4500 1 a dégrossi Assemblée de brûleur LPG ROF4501 1 2 dégrossis Assemblée de brûleur LPG ROF4502 1 De verre Bi pliez l Asse...

Page 35: ...ez la flamme pilote 3 Maintenez pour des 5 secondes additionnelles pour activer la flamme et puis à libérer NOTE Étapes 1 et 2 peuvent devoir être répétées plusieurs fois de mettre à feu le feu Ceci changera selon le gaz étant employé 4 Une fois que le réchauffeur est allumé tournez le bouton à l arrangement élevé pendant une période afin d établir un modèle de flamme Vous pouvez moduler la flamme...

Page 36: ...lamme Ceci devrait regarder la même chose chaque fois après une première période de préchauffage d approximativement 30 minutes Le modèle anormal de flamme peut indiquer un problème avec votre appareil Les médias bloqués d orifices ou de brûlure de gaz qui ont décalé peuvent produire un modèle anormal de flamme Il y a quelques panneaux d avertissement qui pourraient indiquer un problème Odeur peu ...

Page 37: ...ts que vous exige Lisez les instructions Avant d employer l appareil lisez svp le manuel entier pour assurer l utilisation correcte Le manque de suivre ces instructions a pu causer un défaut de fonctionnement de l appareil Ceci a pu avoir comme conséquence la mort des dommages sérieux et ou des dégats matériels Le manque de suivre ces instructions peut également vider votre garantie Endroit d appa...

Page 38: ... ventilation au niveau de plancher sont dans un mur latéral il y aura au moins deux ouvertures Le fond des ouvertures sera au niveau de plancher et au bord supérieur pas plus de 5 pouces 127 millimètres au dessus du plancher Les ouvertures seront également classées espacé à 180 degrés et dégagé 4 Chaque ouverture aura des dimensions minimum afin de permettre l entrée d une tige de diamètre de 1 8 ...

Page 39: ...2 x 8 x 15 2 x 8 x 10 400 pieds carrés Par conséquent cette règle est rencontrée parce que 120 400 0 3 le côté ouvert égale 30 de la surface totale des côtés Avec des murs de tous les côtés mais avec au moins une ouverture permanente au niveau du sol et aucune couverture aérienne Dans une clôture partielle qui inclut une couverture aérienne et pas plus de deux murs au moins 2 côtés de la clôture s...

Page 40: ...uvrable une porte ou une entrée d air non mécanique ou toute autre ouverture dans un bâtiment excepté la ventilation de secondaire plancher Entrée d air mécanique 78 74 in 2000 mm Par exemple un dispositif climatique Assemblée de corps ouvrez 1 dégrossi ou 2 dégrossis Libre NE PEUT PAS être installé au dessus de l unité si n importe quelle partie de l entourage est faite de matériel combustible S ...

Page 41: ...ment de gaz C est commun à toutes les installations Référez vous à ces sections du manuel Préparez une ouverture de raccordement de gaz sous la position d accès d offre de gaz Assurez l ouverture est assez grand pour le raccordement flexible à l ajustement à travers Dimensions Minimum 21 85 in 555 mm 46 26 in 1175 mm 18 50 in 470 mm A B C 17 91 in 455 mm 17 91 in 455 mm 19 68 in 500 mm 8 27 in 210...

Page 42: ...ntière Attachez le linteau en métal et les équerres Linteau en métal A conçu pour se reposer au dessus de l appareil et pour remplacer encadrer combustible dans les secteurs au dessus de l appareil Pour installer 1 Sortez et défaites 4 vis attachantes à l une ou l autre extrémité 2 Renversez les sections latérales 180 et remontez lâchement les vis 3 Ajustez sur la longueur désirée avant le serrage...

Page 43: ...hèses de dégagement au côté intérieur du goujon Revêtement Référez vous à la section aux Directives pour le revêtement et les finitions 48 3 in 1225 mm minimum cabinet non combustible cladding clearance bracket timber stud 46 5 in 1180 mm minimum 47 0 in 1195 mm maximum 19 7 in 500 mm minimum 48 3 in 1225 mm minimum non combustible cladding clearance bracket timber stud 46 5 in 1180 mm minimum 47 ...

Page 44: ... à la clôture 2 à l acte en tant que les contraintes séis miques parenthèses inférieures seulement 3 et pour relier l armature en acier externe dans le coffret Attachez les 4 supports d armature à l aide des bou lons de tête du bouton M5 au corps Installez l armature en acier 1 Il y a un dessus et un bas à l armature en acier avec le dessus ayant un pli de retour L installa tion est accomplie en u...

Page 45: ... seule couche de petites pierres de quartz couvrant le dessus entier de la ponce Placez les 14 morceaux de grandes pierres de quartz sur le petit quartz N empilez pas les grandes pierres sur de grandes pierres Couche 2 À une seule couche du petit quartz Couche 3 À une seule couche de 14 morceaux de grand quartz Couche 1 Ponce Si en utilisant les fireglass ou les médias facultatifs de brûlure de bo...

Page 46: ...stallées et ne doivent pas être stockés dans un bâtiment le garage ou n importe quel autre secteur inclus Le circuit d alimentation de cylindre doit être assuré le retrait de vapeur Le cylindre doit être installé dans une position droite Le gaz doit être arrêté au cylindre quand l appareil est non utilisable Le cylindre doit inclure un collier pour protéger la valve de cylindre 1 Poussez le raccor...

Page 47: ...lée a installé 302 F 150 C sans porte l assemblée a installé 212 F 100 C Les matériaux de revêtement seront non combustibles et appropriés à un environnement extérieur Si vous installez un montage de porte un matériel évalué par chaleur tel que le panneau de silicate de calcium doit être au dessus du feu De tels matériaux exigent l installation et le cachetage selon les spécifications de fournisse...

Page 48: ...ans les conditions qui suivent Toutes les pièces à réparer doivent être des pièces Rinnai d origine Toutes les réparations et tous les replacements doivent être effectués par un dépanneur individuel ou une société de dépannage ayant reçu l autorisation de Rinnai L installateur est responsable de l installation correcte de votre réchauffeur Veuillez remplir l information ci dessous pour garder pour...

Page 49: ...équate catastrophe naturelle installation incorrect comme mais non limité à dommages condensat mise à l air libre inexacte type incorrect de gaz ou pression de gaz incorrecte conversion incorrect conversions y compris pour l ajustement d inventaire entretien ou service inadapté pour toute cause autre que relative aux matériaux et à la main d œuvre de fabrication Cette garantie ne s applique pas à ...

Page 50: ...50 Rinnai Corporation ROF4500 Notes ...

Page 51: ...Rinnai Corporation ROF4500 51 Notes ...

Page 52: ...stat Zero Clearance to Combustibles Accommodates Standard Cased Coils Direct Vent Fireplace RHFE 750ETR Up to 83 AFUE Energy Efficiency Zero Clearance Installation Available in Four Options of Fronts Remotes and Fan Included Gas Conversion Kit Available Tankless Water Heaters Residential and Commercial Applications Continuous Hot Water Up to 9 8 GPM High Energy Efficiency Propane or Natural Gas In...