Rinnai Corporation Hydronic Air Handler Manual
31
Accessories
FIELD SUPPLIED ACCESSORIES
1.
Humidifier (HUM)
Connect an auxiliary 2.5 FLA, 2.5 LRA @ 115 VAC
max Humidifier (if required). Connections are
made via the “HUM” quick connects. The humidifier
output is on whenever a heating demand is being
satisfied. The contacts of this output are isolated to
allow field personnel to apply 24 VAC or 115 VAC
to one terminal and the humidifier load to the other.
2.
Electronic Air Cleaner (EAC)
Connect an auxiliary Electronic Air Cleaner (if
required); rating shall be max 1.0 Amp @ 115
VAC. This output is energized whenever any of the
four blower speeds are energized. Connections
are made via 0.250 x 0.032” male quick connect
terminals labeled "EAC" and "N3".
3.
UV Lamp
Connect an auxiliary UV lamp (if required); rating
shall be max 1.0 Amp @ 115 VAC. This output is
energized whenever any of the four blower speeds
are energized. Connections are made via 0.250 x
0.032” male quick connect terminals labeled "UV"
and "N2"
4.
Filter Rack & Bottom Fill Plates
Refer to Figures 3 and 4 in this manual and the
table below:
5.
Thermostats
The Standard Model thermostat is an electronic
24 vac, programmable, manual changeover
wall-mount thermostat. This thermostat uses two
set points to maintain and control room temperature
in both the heating and air conditioning modes. The
thermostat is designed to ma/-2°F accuracy.
No batteries are required; temperature, blower,
mode, and installer configuration settings are
preserved with power off.
6.
Flow Sensor
Refer to the plumbing section of this manual for
installation instructions. The sensor is packaged
with the air handler in the literature bag affixed
between the filter and filter retention wire.
7. Anti-scald Thermostatic Temperature Control
Valve
Anti-scald thermostatic temperature control valves
are an important part of domestic water plumbing
because they eliminate the scalding and cold water
shocks that can occur in a shower when a toilet is
flushed or a faucet is turned on. In an Open Loop
system (dual function – space heating and
domestic water heating), an anti-scald valve should
be installed when the Tankless Water heater set
thermostat is above 120°F (49°C); refer to local
codes and/or all authority having jurisdiction. For
recommended piping configuration refer to Figure
11. Anti-Scald valve shall be thermostatically
controlled and meet at least the following
specifications:
•
Dual certification ASSE 1016-T and ASSE 1017
•
IAPMO Approved
•
CSA Approved
Constant water temperature under different
operating conditions.
An approved anti-scald/anti-chill thermostatic
temperature control valve is available through the
Rinnai® Accessory Program.
Part Part
Number
Thermostatic Mixing Valve
603000016
Sensor, Flow Actuated
603000010
Part Part
Number
Bottom Fill Plate 37HFA045
603000011
Bottom Fill Plate 37HFA060
603000012
Bottom Fill Plate 37HFA075
603000013
Bottom Fill Plate 37HFA090
603000014
Side Filter Rack
37HFA
603000015
Part Model
Part
Number
Part Part
Number
AC Thermostat
603000018
Heat Pump Thermostat
603000021