Installation and operating instructions for
Brake HW 165 FHM spring activated
–
hydraulically released
E 09.774e
Issue: 08.01.2021
Version: 1
Drawn: BAHS
Checked: EISF Pages: 24
Page: 16
5.2 Manual release: deactivation
1.
With the pressure cut off, remove the cover
21
with its 6 Allen screws
V09
(5mm male key).
Fig. 5.3
2.
For an easier handling, it is possible the remove the connector of indicator switches Fig. 5.4.
Unlock the connector by insert the screwdriver behind the connector and turn it a 1/4 of a turn
counter-clockwise and then insert the screwdriver into the slot at the side to release the
connector.
In ‘ATEX’ execution, it is not possible to remove the connector see Fig. 5.11
3.
Supply the caliper with a pressure of 200bar and maintain it throughout the operation.
Attention!
Retaining segments 14 can be fall. Do not cutting off the pressure without removed
these retaining segment.
4.
Remove the 2 retaining segments
14
Fig. 5.2 and install them in the standby position on the
cover
21
, one on the other, using the 2 screws
V03
. See Fig.5.3.
5.
Reinstall cover
21
and retighten 6 screws
V09
Fig.5.2 chapter 5.1.
V09
21
V03 in release position
V03 in standby
position
14