ring Retrofit Alarm Kit Z-Wave Technical Manual Download Page 6

6

Group Identifier

2

Node ID

Blank/Nothing Entered

Marker

0x00

vg

1 (Press plus button to make the variant group fields appear.)

Multi-Channel Node ID

01 (Controller’s Node ID)

End Point

0x00

Bit Address

Not Selected

Parameter 

Number

Description

Number  

of Bytes

Default

Min

Max

1

Number of seconds between periodic 

battery reports. (Heartbeats)

2

4200 

(0x1068)

255 (0xFF)

4200 

(0x1068)

2

One-Time Wakeup Notification. (In ad-

dition to normal Wakeup Notification)

2

(Not in use).

1 (must be 

divisible by 

sleep step 

time of 

configuration 

parameter 7)

3600 

(0x0E10)

3

Number of Application Level Retries 

after a failed transmission defined as 

either not ACKed or Supervision Report 

not returned when encapsulated.

1

5

1

15

4

The minimum number of seconds to 

sleep between application level retries.

1

6

1

60 

(0x3C)

5

Application Retry Multiplier.  

The number of seconds between a 

current application retry is the count 

of retries multiplied by this number in 

s a small random delay.

1

5

1

5

Association

This sensor has two Association groups with only one node for each group. Group one is a lifeline 
group who will receive unsolicited messages relating to case tamper notifications, battery level 
notifications, Wake-Up notifications, and Device Reset Notifications. Group two is intended to be used 
with multi-channel association for a controller to subscribe to contact switch open/close notifications 
sent encapsulated from each of the eight endpoints one for each contact switch. Each endpoint must 
be enabled by putting the controller’s node ID into the device’s Association Group 2 with either an 
Association Set encapsulated with Multi-Channel Encapsulation OR a Multi-Channel Association Set 
encapsulated with Multi-Channel Encapsulation.

Example Multi Channel Association Set Command:

Configuration

The sensor has seven supported configuration parameters.