10 Product Specifications
10-1. List of specifications
- 49 -
<TIIS Specifications>
Model SD-1RI
Detection principle
Non-dispersive infrared absorption method
Detectable gas
Combustible gas
Gas concentration display
LED(4digits
・
7segments)
Measuring range
Depend on Detectable gas
Resolution
Depend on Detectable gas
Detection method
Diffusion method
Alarm preset point
Depend on Detectable gas
Power indication
POWER lamp lighting(green)
Output
Gas concentration signal
Alarm contact(Gas alarm or Trouble alarm or Gas
・
Trouble common alarm)
Alarm accuracy
(under an identical condition)
Within ±25% to the alarm setpoint value
Alarm-delay time
(under an identical condition)
Within 30sec
(when introducing 1.6 times thicker gas than alarm setpoint value)
Gas alarm type
Single alarm(H)
Gas alarm indication
ALM lamp lighting(red)
Gas alarm action
Auto-recover
Trouble alarm
・
Self diagnosis
System failure/Sensor failure
Trouble alarm indication
FAULT lamp lighting(yellow)/content display
Trouble alarm action
Auto-recover
Alarm contact
No-voltage contact 1a
・
Non-exciting at normal(exciting at alarm) or exciting at
normal(non-exciting at alarm)
Contact capacity
250VAC - 0.5A/30VDC - 0.5A(resistive load)
Transmission scheme
Three-wire analog transmission
(in common with power supply<power supply,signal,common>)
Specification of transmission
4 - 20mA DC (linear/load resistance less than 300
Ω
)
Transmission cable
CVVS1.25 mm
2
or 2.0mm
2
- 3-core(when the contact is not used)
CVVS1.25 mm
2
or 2.0mm
2
- 5-core(when the contact is used)
Transmission distance
Less than 1.25km in case of CVVS 1.25mm
2
Less than 2.0km in case of CVVS 2.0mm
2
Power supply
24 VDC±10%
Power consumption
MAX.2W
Cabling port
Flame proof packing method<G3/4>(Compatible cables
φ
9.6
~
13.0mm in outer diameter )
Initial clear
Approx.25sec
Operating temperature
Depend on Detectable gas(non-rapidly-vary)
Operating humidity
Less than 95%RH(non-condensing)
Structure
Wall mounting type
Explosion-proof structure
Flame proof structure
Explosion-proof class
Ex d
Ⅱ
C T6 X(TIIS<Japan>)
Outer dimension
Approx.148(W)×167(H)×88(D)mm(projection excluding)
Weight Approx.2.0kg
Color Munsell
7.5BG5/2
* The ambient temperature range which maintain a capability of explosion proof of the label on the detector is -20
~
+53
℃
. However,
the available operating temperature range is different depending on detectable gas
(P 51).
Summary of Contents for SD-1RI
Page 1: ...PT2E 1957 Smart transmitter Gas Detector Head SD 1RI Operating Manual PT2E 195 PT2 195 ...
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 31: ......
Page 32: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 47: ......
Page 51: ......
Page 53: ......
Page 55: ......
Page 57: ......