10 Product Specifications
10-1. List of specifications
- 58 -
[SD-1D-AS (TYPE NC)] <ATEX/IECEx Specifications>
Detection principle
New ceramic type
Gas to be detected
Combustible gas
Applicable gas
detector head
SD-1D (TYPE NC)
Concentration display Seven-segment LED (four-digit)
Detection range
Depending on the gas to be detected
Detection method
Aspirator suction type
Sampling condition
Equivalent to atmospheric pressure (compressed air: 0.1 - 0.7 MPa, maximum
use amount: 3 L/min <converted into atmospheric pressure>)
Flow rate
0.8
±
0.1 L/min
Alarm setpoint
25% LEL [standard setting value]
Power display
POWER lamp on (green)
External output
Gas concentration signal/alarm contact (gas alarm or fault alarm, gas/fault
common alarm)
Alarm accuracy
(under
the same conditions)
Within
±
25% to the alarm setpoint value
Alarm delay time
(under
the same conditions)
Within 30 seconds after providing the gas 1.6 times the alarm setpoint (excluding
delay in the tube)
Gas alarm type
One-step alarm (H)
Gas alarm display
ALM lamp on (red)
Gas alarm pattern
Non latching (auto-reset)
Fault alarm/self
diagnosis
System abnormalities/sensor abnormalities
Fault alarm display
FAULT lamp on (yellow)/detail display
Fault alarm pattern
Non latching (auto-reset)
Alarm contact
No-voltage contact 1a, de-energized (energized in response to an alarm) or
energized (de-energized in response to an alarm)
Contact capacity
250 VAC - 0.5 A/30 VDC - 0.5 A (resistance load)
Transmission system
3-wire type analog transmission (common cable for power and signal <power,
signal, common>)
Transmission
specifications
4 - 20 mA DC (linear/load resistance under 300
Ω
, resolution divided into 200)
Transmission cable
CVVS1.25 sq - 3-core or CVVS1.25 sq - 5-core (when the contact is used)
Transmission distance Below 1.25km
Power supply
24 VDC (17
–
26.4 VDC)
Power consumption
Maximum 3 W
Cable connecting port
Pressure proof packing gland
(Cable gland<G3/4> or Adapter A<NPT1/2> or Adapter B<NPT3/4>)
Tube connecting port
Gas IN: Rc1/4 (O.D ø6-1t, half-union for Cu or SUS tube <Bs or SUS> supplied)
OUT: O.D ø8-1t, flare union for Cu or SUS tube (Bs or SUS)
Compressed air IN: O.D ø8-1t, flare union for Cu tube
Initial clear
Approx. 25 seconds
Operating
temperatures
-20 - +60ºC (at a constant condition)
Operating humidities
Below 95% RH (Non-condensing)
Structure
Wall mounting sampling unit (Cu or SUS type)
Explosion-proof
structure
Flame-proof enclosures
Explosion-proof grade
Ⅱ
2G Ex db
Ⅱ
C T5 Gb(ATEX) / Ex db
Ⅱ
C T5 Gb (IECEx)
External dimensions
Approx. 400 (W) x 265 (H) x 102 (D) mm
Weight Approx.
5.6kg
Outer color
Munsell 7.5BG5/2
* Specifications subject to changes without notice.
* When a half-union for gas IN side is changed, check also the external filter (IN/OUT diameter) carefully.
Summary of Contents for PT2-161
Page 1: ...PT2E 2017 Smart Transmitter Gas Detector Head SD 1D AS Operating Manual PT2E 161 PT2 161 ...
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 38: ......
Page 39: ......
Page 42: ......
Page 43: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 55: ......
Page 62: ...10 Product Specifications 10 1 List of specifications 60 Outline Drawings Adapter B NPT3 4 ...
Page 65: ...10 Product Specifications 10 1 List of specifications 63 Outline Drawings ...
Page 68: ......