RIKA VITRA Instruction Manual Download Page 18

 

18 

 

E

N

G

L

IS

H

 

 

 

 

8 .   W A R R A N T Y  

 

WE GUARANTEE 

 
These  warranty  conditions  are  only  valid  for  the  following 
countries:  Austria,  Germany  and  Switzerland.  Separate 
conditions  imposed  by  the  importer  apply  for  all  other 
countries 
  
For  the  purpose  of  timely  damage  limitation, the  warranty 
claim  on  the  part  of  the  claimant  is  to  be  enforced  at  the 
RIKA  dealer  in  writing  using  the  invoice  and  stating  the 
purchase date, model name, serial number and reason for 
complaint. 
  
WARRANTY 
  
5 years on the welded stove body. This exclusively applies 
to  defects  in  materials  and  workmanship  as  well  as  free 
replacement.  Labour  and  travel  times  are  not  included  in 
the manufacturer’s warranty. 
  
Only original parts supplied by the manufacturer should be 
used. Loss of warranty on non-observance! 
  
The  precondition  for  the  warranty  is  that  the  stove  has 
been installed and commissioned properly according to the 
User  and  installation manuals  valid  at  the  time  of  purcha-
se. Connection must be performed by a specialist for such 
stoves. 
 
Any  costs incurred  by  the manufacturer  due  to  unjustified 
warranty claims are to be charged to the claimant. 

 
 
  
 
W e a r   p a r t s  and parts affected by fire are excluded, such 
as glass, coating, surface coatings (e.g. handles, panels), 
seals,  fire  trough,  grates,  draught  plates,  deflector  plates, 
combustion  chamber  liners  (e.g.  fireclay),  ceramics,  natu-
ral  stone,  thermo  stone,  ignition  elements,  sensors,  com-
bustion chamber sensors and temperature controller. 
 
Damage  arising  from  non-observance  of  the  manufactu-
rer’s  instructions for  operation  of the  unit    or  any  damage 
that is caused by action such as overheating, use of non-
approved  fuels,  tampering  with  the  device  or  the  flue  gas 
pipe, electrical excess voltage, an incorrect, insufficient or 
excessive flue draught, condensation, non-performance or 
deficient  maintenance  and  cleaning,  non-observance  of 
the relevant and applicable building regulations,  incorrect 
operation  by  the  user  or  third  parties,  transport  and  han-
dling damage is also excluded. 
  
THE  WARRANTY  DOES  NOT  AFFECT  THE  STATU-
TORY WARRANTY PROVISIONS. 

 

 
 

Summary of Contents for VITRA

Page 1: ...1 VITRA Instruction manual ...

Page 2: ...2 ...

Page 3: ...3 Flue pipe connec tion with original angle pipe Connection dimensiones ...

Page 4: ...4 Furnance door ...

Page 5: ...5 Furnance Casing 55 54 ...

Page 6: ...al combustion air feed 12 4 Operation Lighting the fire 13 Ash drawer 14 Operating the shaker grate 14 Rotary control knob 14 5 FITTING OPTIONS Changing flue pipe connection above to connection at rear 15 6 MAINTENANCE AND CLEANING General maintenance 16 Finish condition and cleaning 16 Convection air openings 16 Cleaning the flue gas channels 16 7 PROBLEM SOLVING What to do if 17 8 GUARANTEE AND ...

Page 7: ...re 214 2 C Minimum flow pressure at rated heating ca pacity 12 Pa The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to submit it to the authorities or the chimney sweep on request PARTS OVERVIEW Description 01 Furnance door machined Z33564 02 Door glass Z33465 03 Glass holder L00475 04 Lens head screw with ISK 10883...

Page 8: ...bustion or introduction of highly flammable or explosive materials such as empty spray cans etc in the combustion chamber and storing them near the stove is strictly prohibited due to the danger of explo sion No light or inflammable clothing is to be worn when post heating Placing non heat resistant objects on the stove or near it is prohibited Do not place clothing on the stove to dry Stands for ...

Page 9: ... fires BA 1 These fires must only be operated with the fire door closed 1 8 The fire door must only be opened for adding fuel and must then be closed again as this could otherwise lead to a danger to other fires that are also connected to the chimney 1 8 1 When the fire is not in operation the fire door must be kept closed 1 9 When using wet fuel and if operation is throttled too much the chimney ...

Page 10: ...WOOD TYPES Different types of wood have different fuel values Decidu ous wood is particularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all soft woods and tends to spray sparks MAXIMUM FUEL QUANTITIES Wood 2 logs of approx 0 6 kg Wood briquettes broken 2 pieces of approx 0 6 kg The output of your stov...

Page 11: ...mage or soiling of the fire and chimney as well as the environment 2 THE RIGHT QUANTITY OF FIREWOOD AND FIREWOOD DIMENSIONS Too much firewood leads to overheating This stresses the material too much and leads to poor flue gas values Too little firewood or logs being too large means the stove does not reach optimum operating temperature The flue gas values are also poor in this case The right quant...

Page 12: ...nnection may not project into the chimney shaft Seal the gap between flue pipe and wall liner with ceramic sealer The installation must conform to the respective safety and building regulations Please contact your master chimney sweep in this context He will be pleased to inform you If you use a system chimney e g glazed fireclay we would ask you follow the manufacturer s connection instructions c...

Page 13: ...olours pro duce very poisonous substances in the flue gas 3 Now light the paper Wait until the soft wood chips are burning well Close the shaker grate handle and the pri mary air slide a few minutes later Set the secondary air slide to the ideal setting a few minutes later 4 After this has burned lay approx 1 3 kg wood 2 billets on the fire Open the shaker grate handle and the primary air slide un...

Page 14: ...heating loss of warranty Caution Embers could remain in the ash Only fill the ash into non flammable containers and do not put the ash onto flammable surfaces OPERATING THE SHAKER GRATE Page 4 Part 27 The ash is moved from the fire into the ash drawer by moving the shaker grate handle to and fro This frees up room for the primary feed air that is required for the heat ing phase in the fire The sha...

Page 15: ...l part 46 using a hacksaw Please remember when changing the flue pipe connec tion that the individual parts of the soapstone panel ling weight about 34 kg In addition the surfaceof the soapstone should be protected to prevent scratching Swap the flue gas connector and the hob part 51 53 with each other Fit the new plate fins part 43 must be optionally or dered Make sure your fingers do not become ...

Page 16: ...ss cleaner can be obtained from your special ist fire dealer Should the glass become heavily sooted the possible cause could be damp wood The fire finish is highly refractory and must only be cleaned using a cloth damp if necessary Only use original paint for touch up work this is available from your specialist dealer as an accessory Under no circumstances must the paint be cleaned before heating ...

Page 17: ...y 2 Stove does not draw properly Chimney draught insufficient Stove is sooted over inside See A small study of heating See Maintenance and cleaning 3 Stove does not start burning properly Weather influence Incorrect heating up See Fire lighting See Fire lighting 4 Stove smells strongly and smokes outside Burning in phase Stove is dusty dirty See Operation curing of coating See Convection air openi...

Page 18: ...at the time of purcha se Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts affected by fire are excluded such as glass coating surface coatings e g handles panels seals fire trough grates draught plates deflector plates combustion chamber liners e g fireclay c...

Page 19: ...19 ...

Page 20: ...20 G U A R A N T E E G A R A N T I E Customer Client To A Stamp Marque Z33571 2011 05 05 ...

Reviews: