16
8. WARNINGS AND MALFUNCTION MESSAGES
LED display
Meaning
Action to be taken
X
X
The display lamp flashes
1x RED and 1x YELLOW
The temperature sensor outputs incorrect values
The temperature sensor is defective
Check whether dirt or soot has accumulated at
the temperature sensor and if required clean the
sensor carefully (see Cleaning and Maintenance)
Contact RIKA customer service
XX
X
The display lamp flashes
2x RED and 1x YELLOW
The magnetic switch is defective or jammed
The air flaps are jammed
Check whether an object is blocking the air flaps
Contact RIKA customer service
XXX
X
The display lamp flashes
3x RED and 1x YELLOW
The air flap motor cannot move to position
Contact RIKA customer service
XXXX
X
The display lamp flashes
4x RED and 1x YELLOW
Complete closing of the air flaps is not possible
Contact RIKA customer service