RIKA ROCO Operating Manual Download Page 6

6

Spare part overview article numbers

#

Art.Nr.:

Description

1

Z34847

combustion chamber door black

2

N100485

Round sealing strip D12

3

N103693

culimeta flat packing black 8x2

4

Z34877

door glas (ceramic glass)

5

Z34855

hinge plate

6

N103964

Hexagonal screw M06x16

7*

Z30550

hinge

7**

Z34441

hinge

8*

N108656

Hexagonal nut M08

8**

N105179

Hexagonal nut M10

9

L00475

glass holder

10

N111799

Hexagonal screw M05x08

11

L02221

stop angle

12

N111990

Hexagon socket M04x06

13

L02217

stopper holder

14

Z34854

hinge shaft

15

N110501

shaft securing device

16

N111950

Hexagonal screw M05x10

17

N100170

lining disc

18

L02220

lock tongue

19

Z34857

Locking bolt

20

L02216

closure flap

21

L02219

holder plate

22

N111856

Hexagonal countersunk screw M04x12

23

N111956

allen screw M03x06

24

N111961

Hexagon socket M06x25

25

Z34846

lid

26

N100485

Round sealing strip D12

27

Z35062

distance

28

N100485

Round sealing strip D12

29

Z34872

Flue plate 2

30

Z35095

Flue plate 1

31

Z34870

combustion chamber liner rear 

32

Z34868

combustion chamber side rear 

33

Z34866

combustion chamber side front 

34

N103066

Round sealing strip D06 (Recess)

35

B16310

fire trough holder

36

N111846

Hexagon socket 06x12

37

L02215

ash drawer

38

N111959

milled nut M05

39

N103693

culimeta flat packing black 8x2

40*

Z35059

cleaning cover

40**

B17282

cleaning cover

41

Z35096

pressure Pipes

42

N100141

Hexagonal nut M05

43

Z35060

fire trough

44

Z34867

combustion chamber side front 

45

Z34869

combustion chamber side rear left (till nr.: 

1314345)

46

B16053

sensor tube

47

L01445

switch distance

48

N111733

Solenoid switch lower part

49

N111842

Hexagon socket M03x10

50

N111732

magnetic switch upper section

51

L01502

Lock washer

52

N110461

double ball catch

53

L01446

Lock washer

54

LB00543

lid metallic

LB00542

lid black

55

L02243

hinge lid

56

Z34854

hinge shaft

57

N110501

shaft securing device

#

Art.Nr.:

Description

58

L02244

lid stove

59

LB00545

convection cover metallic

LB00544

convection cover black

60

L02273

rear wall metallic

L02271

rear wall black

61

L02254

Suspended sheet

62

N111986

telescopic rail

63

N111645

spring plug

64

Z35098

latching bolt

65

N111983

carriage bolt M06x20

66

Z35237

cover

67

LB00549

Right side panel metallic

LB00548

Right side panel black

68

N111730

grommet

69

N111695

height adjustment screw

70

L02274

cocer rear wall metallic

L02272

cover rear wall black

71

L02228

Suspended sheet

72

B17016

stone holder

73

Z34879

lower soapstone 

Z35205

lower stone white

Z35203

lower sandstone

74

B17020

sliding door decor

75

LB00547

Left side panel metallic

LB00546

Left side panel black

76

N111982

Hexagonal screw M06x18

77

Z34880

upper soapstone 

Z35204

upper stone white

Z35202

upper sandstone

78

N111731

container seal

79

Z35108

combustion fan cover 

80

B16114

Temperature sensor

81

Z35183

Sintered bearing Di10

82

B12301

screw

83

B17014

ceramic ignition

84

N111058

setscrew with ISK and pin

85

B16155

Induced draft fan housing

86

N105627

Hexagonal screw M06x40

87

N111581

induced draught fan motor

88***

Z35182

Plastic bearing

89

Z11915

lock ring conveyer screw

90

N111985

pressure difference guide

91

N111820

Screw motor, stepless

92

B16561

mainboard USB11

93

N110696

fuse 2,5A

94

N111989

USB cable

95

B16030

additional board

96

L01495

lid

97

B16574

touch-Display

98

N112000

Convection fan motor

B17023

Cabletree

N111551

silicone Hose

L00797

motor plate

Z35018

Cable touch display

*

(till serial number 1320321)

**

(from serial number 1320322)

Summary of Contents for ROCO

Page 1: ...Operating Manual ROCO MULTI AIR...

Page 2: ...1 Pressure monitoring 11 Overheating 11 Low temperature shutdown 11 Electrical excess current protection 11 Component monitoring 11 Power failure during heating 11 Power failure during the initial sta...

Page 3: ...Convection fan control Manual Automatic 22 Pellet container refilling 22 Emergency operation heating up without electrical Ignition 22 10 WARNING AND ERROR MESSAGES 23 Warnings 23 Errors 24 11 CLEANI...

Page 4: ...Spare part overview exploded diagram 1 3 4 10 10 5 5 6 6 11 12 14 15 7 7 8 8 13 19 23 21 22 18 16 2 20 6 9 9 17 27 25 24 31 33 32 44 30 29 39 40 38 38 35 34 36 43 37 41 42 45 46 28 26...

Page 5: ...5 EN 4 47 48 49 50 53 51 52 54 55 58 56 57 59 60 70 67 68 66 61 71 71 63 64 64 76 65 69 62 62 77 72 73 72 74 75 68 78 96 81 82 88 80 83 85 87 86 91 89 84 90 94 92 95 93 97 85 98 79...

Page 6: ...x10 50 N111732 magnetic switch upper section 51 L01502 Lock washer 52 N110461 double ball catch 53 L01446 Lock washer 54 LB00543 lid metallic LB00542 lid black 55 L02243 hinge lid 56 Z34854 hinge shaf...

Page 7: ...the size of the pellets The larger the pellet the slower the feed and vice versa The owner of small firing systems or the person authorised for the small firing system is to keep the technical documen...

Page 8: ...of operation operating handle Q Make your children aware of this particular danger and keep them away from the stove during heating Q Only burn approved heating materials Q The combustion or introduc...

Page 9: ...ions may be connected to your chimney Q Only use suitable tools from our range of accessories when handling embers and make sure that no embers fall out of the combustion chamber onto inflammable mate...

Page 10: ...1 10 arsenic content mg kg 1 1 cadmium content mg kg 1 0 5 mercury content mg kg 1 0 1 lead content mg kg 1 10 nickel content mg kg 1 10 zinc content mg kg 1 100 1 in an anhydrous state 2 diameter mu...

Page 11: ...in a room together with a kitchen hood it might happen that the built in pressure switch stops the stove If using the hood make sure make sure that an adequate supply of air is ensured Overheating A...

Page 12: ...flowing downwards is heated it may rise and thus counter the chimney with a resistance which in turn reduces the negative pressure in the combustion chamber The chimney manufacturer is to guarantee t...

Page 13: ...e attachments Select soft bases to prevent scratches to your living space furniture and stove panels Dismantling stone Loosen the 4 Allen screws and slide the confection fins to the right You can pick...

Page 14: ...Now you can remove the two bottom hex nuts including washers You can now lift off the bottom stone forward Mount the removed parts in reverse order 10 10...

Page 15: ...tatus returns to active or inactive active depressed inactive Input posibilities OFF Button Pressing the OFF button switches off the section concerned ON Button Pressing the ON button switches on the...

Page 16: ...ears after successful software update the stove must be disconnected from the mains and the USB stick removed First steps Once the stove has been reconnected to the mains the display changes to the da...

Page 17: ...following functions HOME status level Stove start stop setting heat output room set temperature current stove status display MODE operating mode level Selection of the required operating mode manual...

Page 18: ...er is activated is set in this submenu USB update This menu level concerns the software update of the stove Service not accessible to final customers Additional information for the specialist dealer o...

Page 19: ...s ON OFF 810 Output Th 15 03 2012 15 55 Ignition Grid Motor Air Control Box inc Discharge motor Current speed of screw motor conveying away from the pellet container range 0 1000 Feed motor Current sp...

Page 20: ...d settings HEATING TIMES This symbol is highlighted if individual heating times are activated ROOM SENSOR This symbol is highlighted if a functioning room sensor is connected FROST PROTECTION This sym...

Page 21: ...ove has an interface on the rear wall to which you can connect a customary room thermostat This requires a 2 pole cable of 0 5 0 75 mm cross section that you have to connect instead of the cable bridg...

Page 22: ...ation OFF no pellet burner start is possible the system is turned off Convection fan control Manual Automatic MANUAL MODE In manual mode you can turn on the convection fan to a desired air level level...

Page 23: ...gas flap is activated and the stove is automatically switched off Warnings display meaning action to be taken Please Close Door WARNING PELLET CONTAINER LID OPEN Display for open combustion chamber do...

Page 24: ...EYOR DEFECT One of the two screw motors for pellet conveying can no longer be actuated Acknowledge error message and restart stove FEHLERMELDUNG FLAMMSENSOR DEFEKT The flame temperature sensor in the...

Page 25: ...mineral content of the wood remains in the combustion chamber as ash as a residue of the combustion This is an excellent fertiliser for all plants in the garden it is a completely natural product The...

Page 26: ...two hex screws and remove the cleaning lid Now clean the flues with the included wire brush Suck the combustion residues out of the deflection region Remove the ash tray Open the 4 thumb screws and r...

Page 27: ...ainer immediately remove the residues dust chippings etc from the empty container The unit must be disconnected from the mains Checking door seal The condition of the seals at doors and glass should b...

Page 28: ...ompany Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in phase a...

Page 29: ...hat are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in the putting into operation It is v...

Page 30: ...tware version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present Function checked Check of system components C...

Page 31: ...urchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts af...

Page 32: ...heldorf Austria M llerviertel 20 Telefon 43 7582 686 41 Fax DW 43 E Mail verkauf rika at RIKA AT Technical and design changes as well as typesetting and printing errors reserved 2014 RIKA Innovative O...