RIKA ROCO Operating Manual Download Page 29

|

29

EN

28

13. INSTRUCTIONS FOR COMMISSIONING PROTOCOL 

FOR PELLET AND COMBI STOVES

The commissioning protocol is to be treated as a documents and serves as 

the basis for the warranty and guarantee terms. It is to be completed entirely, 

in particular the stove data and addresses, the work to be performed is to be 

ticked off after completion. The signatories confirm with their signatures that all 

the items on the list have been concluded properly.

Note

Please return 1 completed protocol for putting into service to RIKA Innovative 

Ofentechnik GmbH, Müllerviertel 20, A-4563 Micheldorf.

Electrical periphery

It is important that the connection socket in the electrical periphery is earthed. 

The operability of any room thermostat present must be checked. The execution 

of commands is to be established by phoning in the case of a GSM modem.

Exhaust gas system

The exhaust line, stove and combustion air inlet are part of the combustion 

system as a whole; therefore the correct execution must also be checked. The 

plug connections should be tight in general since the system works with excess 

pressure. The exhaust tube has a diameter of 150 mm which is sufficient for 

short distances. In the case of several changes in direction, the resistance 

of the exhaust system can increase with the flue to such an extent that the 

combustion quality suffers and/or noises arise from the greater flow speed. 

Correct determination of the chimney draught can only be performed at nominal 

thermal output and serves to evaluate the chimney. If the draught is more than 

15 Pa, then a draught limiter should be installed.

Stove functions

These are the basic stove functions that are to be checked and ticked off. The 

stove is ready for operation if these functions are ensured.

Operator instruction

This is one of the most important points in the putting into operation. It is very 

important that the operator understands the stove properly and is prepared to 

assume responsibility for the basic tasks required for operational safety.

In particular the connection between special features of a biomass heating 

system and his obligations as well as the warranty and guarantee terms must 

be explained. e.g. non-tested pellets and screw blockers, lack of cleaning or 

maintenance and stove malfunctions. Thorough instruction can prevent many 

complaints.

Stove functions

Explanation of the processes in the stove during ignition, normal operation, 

cleaning phase etc.

Control

Explain operator’s possibilities to intervene, empty pellet container, room 

thermostat, GSM modem, functions and settings, program times if necessary. 

Operating instructions: Handover and reference to the content to the following 

points, is a document.

Warranty terms

Difference between warranty (statutory) and guarantee (voluntary), terms of 

guarantee, determination of wearing parts, reference to pellet quality to be 

used and the consequences of poor quality.

Cleaning instructions

Ash and dust occurs with a biomass heating unit. The fire trough is to be 

cleaned regularly with regular heating operation (in the case of pellet operation, 

the drilled air holes in particular must be free of residues). The ash drawer is 

to be emptied regularly. The flue gas pipes are to be cleaned once or twice in 

the heating season depending on stove type; by a specialist company is best.

Maintenance

Maintenance work after defined burn-off output is to be performed by specialist 

company, including thorough cleaning.

Combustion

All doors must close tightly to prevent intake of false air.

Summary of Contents for ROCO

Page 1: ...Operating Manual ROCO MULTI AIR...

Page 2: ...1 Pressure monitoring 11 Overheating 11 Low temperature shutdown 11 Electrical excess current protection 11 Component monitoring 11 Power failure during heating 11 Power failure during the initial sta...

Page 3: ...Convection fan control Manual Automatic 22 Pellet container refilling 22 Emergency operation heating up without electrical Ignition 22 10 WARNING AND ERROR MESSAGES 23 Warnings 23 Errors 24 11 CLEANI...

Page 4: ...Spare part overview exploded diagram 1 3 4 10 10 5 5 6 6 11 12 14 15 7 7 8 8 13 19 23 21 22 18 16 2 20 6 9 9 17 27 25 24 31 33 32 44 30 29 39 40 38 38 35 34 36 43 37 41 42 45 46 28 26...

Page 5: ...5 EN 4 47 48 49 50 53 51 52 54 55 58 56 57 59 60 70 67 68 66 61 71 71 63 64 64 76 65 69 62 62 77 72 73 72 74 75 68 78 96 81 82 88 80 83 85 87 86 91 89 84 90 94 92 95 93 97 85 98 79...

Page 6: ...x10 50 N111732 magnetic switch upper section 51 L01502 Lock washer 52 N110461 double ball catch 53 L01446 Lock washer 54 LB00543 lid metallic LB00542 lid black 55 L02243 hinge lid 56 Z34854 hinge shaf...

Page 7: ...the size of the pellets The larger the pellet the slower the feed and vice versa The owner of small firing systems or the person authorised for the small firing system is to keep the technical documen...

Page 8: ...of operation operating handle Q Make your children aware of this particular danger and keep them away from the stove during heating Q Only burn approved heating materials Q The combustion or introduc...

Page 9: ...ions may be connected to your chimney Q Only use suitable tools from our range of accessories when handling embers and make sure that no embers fall out of the combustion chamber onto inflammable mate...

Page 10: ...1 10 arsenic content mg kg 1 1 cadmium content mg kg 1 0 5 mercury content mg kg 1 0 1 lead content mg kg 1 10 nickel content mg kg 1 10 zinc content mg kg 1 100 1 in an anhydrous state 2 diameter mu...

Page 11: ...in a room together with a kitchen hood it might happen that the built in pressure switch stops the stove If using the hood make sure make sure that an adequate supply of air is ensured Overheating A...

Page 12: ...flowing downwards is heated it may rise and thus counter the chimney with a resistance which in turn reduces the negative pressure in the combustion chamber The chimney manufacturer is to guarantee t...

Page 13: ...e attachments Select soft bases to prevent scratches to your living space furniture and stove panels Dismantling stone Loosen the 4 Allen screws and slide the confection fins to the right You can pick...

Page 14: ...Now you can remove the two bottom hex nuts including washers You can now lift off the bottom stone forward Mount the removed parts in reverse order 10 10...

Page 15: ...tatus returns to active or inactive active depressed inactive Input posibilities OFF Button Pressing the OFF button switches off the section concerned ON Button Pressing the ON button switches on the...

Page 16: ...ears after successful software update the stove must be disconnected from the mains and the USB stick removed First steps Once the stove has been reconnected to the mains the display changes to the da...

Page 17: ...following functions HOME status level Stove start stop setting heat output room set temperature current stove status display MODE operating mode level Selection of the required operating mode manual...

Page 18: ...er is activated is set in this submenu USB update This menu level concerns the software update of the stove Service not accessible to final customers Additional information for the specialist dealer o...

Page 19: ...s ON OFF 810 Output Th 15 03 2012 15 55 Ignition Grid Motor Air Control Box inc Discharge motor Current speed of screw motor conveying away from the pellet container range 0 1000 Feed motor Current sp...

Page 20: ...d settings HEATING TIMES This symbol is highlighted if individual heating times are activated ROOM SENSOR This symbol is highlighted if a functioning room sensor is connected FROST PROTECTION This sym...

Page 21: ...ove has an interface on the rear wall to which you can connect a customary room thermostat This requires a 2 pole cable of 0 5 0 75 mm cross section that you have to connect instead of the cable bridg...

Page 22: ...ation OFF no pellet burner start is possible the system is turned off Convection fan control Manual Automatic MANUAL MODE In manual mode you can turn on the convection fan to a desired air level level...

Page 23: ...gas flap is activated and the stove is automatically switched off Warnings display meaning action to be taken Please Close Door WARNING PELLET CONTAINER LID OPEN Display for open combustion chamber do...

Page 24: ...EYOR DEFECT One of the two screw motors for pellet conveying can no longer be actuated Acknowledge error message and restart stove FEHLERMELDUNG FLAMMSENSOR DEFEKT The flame temperature sensor in the...

Page 25: ...mineral content of the wood remains in the combustion chamber as ash as a residue of the combustion This is an excellent fertiliser for all plants in the garden it is a completely natural product The...

Page 26: ...two hex screws and remove the cleaning lid Now clean the flues with the included wire brush Suck the combustion residues out of the deflection region Remove the ash tray Open the 4 thumb screws and r...

Page 27: ...ainer immediately remove the residues dust chippings etc from the empty container The unit must be disconnected from the mains Checking door seal The condition of the seals at doors and glass should b...

Page 28: ...ompany Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in phase a...

Page 29: ...hat are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in the putting into operation It is v...

Page 30: ...tware version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present Function checked Check of system components C...

Page 31: ...urchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts af...

Page 32: ...heldorf Austria M llerviertel 20 Telefon 43 7582 686 41 Fax DW 43 E Mail verkauf rika at RIKA AT Technical and design changes as well as typesetting and printing errors reserved 2014 RIKA Innovative O...

Reviews: