background image

8

Spare part overview article numbers

Nr. Art.Nr.

Description

1

B18905

Oven decorative door

2

Z38543

Magnet shell

3

N112758

Magnet

4

N108485

Allen screw

5

N111973

Hexagonal nut

6

N111950

Hexagonal screw M05x10

7

L03825

Magnet holder plate

8

Z38463

Wooden handle

9

L03823

Mounting bracket for handle

10

N110032

Hexagonal screw

11

N107134

Hexagonal countersunk screw

12

L03822

Door mounting plate 

13

Z35996

Hanger plate 

14

Z38464

Teflon washer

15

Z33758

Spacer

16

N108121

Self-tapping screw

17

L03824

Door stop

18

Z38462

Teflon washer

19

Z35995

Door mounting plate 

20

Z35992

Hinge

21

Z38066

Cast frame black

22

Z37460

Door glass oven

23

N111789

Grub screw

24

L00475

Glass holder

25

N112177

Hexagon socket screw

26

N108395

Hexagon socket screw

27

B17524

Hinge black

28

B17405

Hinge

29

N111780

Hexagonal nut

30

L02645

Door stop base plate

31

N105049

Flat washer black

32

B16814

Hinge

33

N112201

Hexagon socket screw

34

Z35464

Combustion chamber door black

35

N112551

Round sealing strip grey D11

36

N103693

Flat seal black 8x2

37

Z35856

Front door glass

38

B12322

Closure plate

39

N100170

Washer

40

B17407

Shutter

41

L02647

Closure plate

42

N112190

Hexagon socket screw

43

N112551

Round sealing strip grey D11

44

N112603

Glass fabric tape adhesive

45

Z35465

Front door black assy

46

N112240

Self-tapping screw

47

Z38461

Cover plate

48

B17521

Pressure spring

49

N111990

Hexagon socket

50

Z36171

Electromagnet

51

Z35993

Door mounting plate 

52

Z27866

Spacer

53

L03831

Door stop

54

N112728

Edge guard

55

B18804

Decorative door

56

N112382

Hexagonal countersunk screw

57

L02714

Magnet washer

58

N112111

Rubber buffer

Nr. Art.Nr.

Description

59

N112175

Washer

60

N112729

Spacer

61

N109233

Hexagonal nut

70

Z32838

Shelf support

71

Z37435

Grill

72

E16210

Baking tray

80

N112716

Sealing cord D08

81

Z38451

Cleaning opening

82

N112414

Wing nut

83

N103988

Hexagonal nut M06

84

N112734

Grub screw

85

N112240

Self-tapping screw

86

Z38577

Mounting bracket for cleaning opening

87

Z38484

Mounting bracket for cleaning opening

88

Z38454

Baffle plate left

89

Z37455

Baffle plate right

90

Z38453

Firebrick lining right

91

Z36576

Cast rear panel black

92

Z36601

Firebrick lining left

93

N112726

Cap nut

94

N112487

Washer

95

Z38467

Seal plate

96

N112415

Hexagonal screw

97

N112269

Washer

98

Z37386

Actuator

99

Z37387

Silicone ring

100

Z37388

Wooden handle

101

Z37390

Handle sleeve

102

Z38090

Intermediate shaft

103

N111723

Hexagon socket screw

104

N111864

Grub screw

105

Z38466

Axis fluegas flap

106

L03827

Rear flapsheet

107

L03828

Front flapsheet

108

B18809

Forkhead complete

109

N112760

Pressure spring

110

N100475

Flat packing white 8x2

111

Z38465

Bearing plate

112

Z18997

Rubber buffer

113

Z36778

Blind cover

114

N100475

Flat packing white 8x2

115

N110833

Self-tapping screw

116

Z37844

Pipe adapter

117

Z37830

Pipe adapter seal

118

Z37832

Intermediary

119

N108485

Allen screw

120

N111058

Setscrew with pin

121

N112125

Circlips

122

Z35853

Drive shaft

123

N102688

Sinter bearing ID16

124

Z35852

Bearing clamping plate

125

Z35851

Bearing plate

126

Z36167

Ceramic seal

127

N112470

Spring clip

128

Z35854

Intermediate shaft dumping grate

129

N108131

Pressure spring

130

L01875

Driving plate dumping grate

131

Z35808

Grid

Summary of Contents for DOMO Back

Page 1: ...DOMO BACK Operating manual...

Page 2: ...ction 13 4 BRIEF INFORMATION ON FUEL PELLETS 14 What are pellets 14 Wood pellet specification according to ENplus A1 14 Pellet container refilling during operation 14 Pellet storage 14 5 TECHNOLOGY AN...

Page 3: ...aces 22 9 CLEANING 23 Clean convection air openings 23 Clean combustion air intake 23 Clean pellet container 23 Clean flue gas channels and flue gas collecting duct 23 Clean flue pipes 24 Check bearin...

Page 4: ...33 35 40 41 42 51 10 19 10 13 6 20 6 18 10 10 12 19 20 6 13 6 9 8 11 10 14 17 15 16 7 6 5 2 3 4 21 22 24 24 25 25 23 23 23 26 26 53 52 16 54 31 45 43 27 27 40 41 42 44 38 38 39 39 4 4 29 29 29 29 32 3...

Page 5: ...3 85 87 81 80 85 82 82 82 91 92 90 89 88 138 137 136 82 135 134 133 140 131 132 132 96 96 141 139 115 130 128 129 127 126 125 123 124 119 122 120 121 118 117 116 115 115 114 113 85 114 113 85 114 113...

Page 6: ...158 159 155 155 157 152 154 153 168 161 169 160 161 155 170 161 171 154 153 154 154 172 161 154 173 174 154 167 194 194 189 189 191 191 190 190 193 193 177 183 187 176 176 176 185 188 178 175 180 192...

Page 7: ...4 201 206 207 209 208 210 224 238 240 241 215 239 247 259 249 250 243 242 242 248 253 252 245 246 256 244 246 246 254 210 255 244 233 230 235 236 237 229 227 226 228 227 226 225 234 232 231 257 258 22...

Page 8: ...804 Decorative door 56 N112382 Hexagonal countersunk screw 57 L02714 Magnet washer 58 N112111 Rubber buffer Nr Art Nr Description 59 N112175 Washer 60 N112729 Spacer 61 N109233 Hexagonal nut 70 Z32838...

Page 9: ...956 Grub screw 194 L02244 Hinge stove 200 B17289 Touch display 201 N112769 Halogen lamp 202 N112759 Cross head screw Nr Art Nr Description 203 B18907 Oven lighting complete 204 Z38547 Sealing internal...

Page 10: ...10 Exhaust g s 6 2 Exhaust temperature C 178 1 Chimney draft requirement Pa 3 The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentat...

Page 11: ...e connection must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular...

Page 12: ...at resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q W...

Page 13: ...wind break 2 chimney 3 inspection opening For the selection of the connection and to ensure a proper connection between the stove and chimney please read the guide INSTALLING THE STOVE or ask your loc...

Page 14: ...h a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list of monitored fuel manufa...

Page 15: ...ng the operational safety The status indicator CLEAN appears on the display Only for stoves with turning grids Every 6 hours interval adjustable an additionally automatic big cleaning cycle is perform...

Page 16: ...ur fingers and any panels and stove attachments Select soft bases to prevent scratches to your living space furniture and stove panels Tip Right Left according to standing in front of the stove Disman...

Page 17: ...o wing screws off the side panel Tilt the panel outwards and lift it up Open the pellet container lid until it stops In this position it remains open Remove the two hexagonal screws Tilt the side pane...

Page 18: ...container they can block the screw conveyor and damage the stove Note During any conversion work take particular care of your fingers and any panels and stove attachments Select soft bases to prevent...

Page 19: ...ainst each other Place the correspondent flue pipe on the side Make sure that everything is tight Install the removed parts in reverse order Rear top connection R4 Remove the handle of the flue gas fl...

Page 20: ...ting shield Note Operation of the stove without an assembled heat protectingshield is not allowed and leads to loss of warranty Place the 90 elbow with cleaning lid to the flue gas stack Make sure tha...

Page 21: ...rated in either MANUAL or AUTOMATIC MODE In both MODES the current set heat output is used in AUTOMATIC MODE the heating times set at the stove can also be activated You can see whether the external d...

Page 22: ...or clinker from the combustion chamber from the fire trough and the turning grid regularly Use the cleaning function to put the grid vertical Remove the clinker using the brush supplied and sweep the...

Page 23: ...lean combustion air intake Note Only when the stove is cold You could vacuum out embers FIRE RISK If necessary please also clean the air intake with a hoover Clean pellet container Do not refill the c...

Page 24: ...t and dust deposits in the fire and in the flue pipes and vacuum Note Accumulated fly ash in the flue gas channels may impair the performance of the stove and pose a safety risk Check bearings annuall...

Page 25: ...see CLEANING and MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end...

Page 26: ...se are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in...

Page 27: ...ght Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YES...

Page 28: ...fessional certified for that type of stove The installation is performed by a RIKA certified technician The stove is registered with RIKA by the RIKA specialist dealer importer on the RIKA Service Por...

Page 29: ...uct life cycle In accordance with the European Directive 2012 19 EU Waste Electrical and Electronic Equipment WEEE and other local regulations RIKA supports the setup of take back systems and recyclin...

Page 30: ......

Page 31: ...31 EN 30...

Page 32: ...ly valid one Subject to technical and visual changes as well as layout and printing errors 2020 RIKA Innovative Ofentechnik GmbH Z38569_Domo_Back_EN 16 07 2020 RIKA Innovative Ofentechnik GmbH M llerv...

Reviews: