|25
EN
24
Run the cable between the supply air duct and the conveyor trough
back to the green marked vertical cable duct.
In the bottom cable channel are the three pin connector M3 for the
upper convection fan 1 and the plug M4 for the lower convection fan
2. Insert the correct cable and put all cables and plugs back into the
cable channel.
Loosen the nut and the ring from the capacitor till the end from the
thread.
Attach the condenser (with 2 blowers both capacitors) in the free
slots.
Install the rear wall of the stove. It is mandatory to attach the motor
cover on the rear wall.
Note
Operation without a motor cover and without air duct is not allowed
for security reasons. Disregard voids your warranty and no liability
is accepted for damage.
Function test and settings
Connect the power cord back in and select the
Setup menu /
submenu
Service.
Perform a relais test to check the correct function
of the Multi Air fan.
Select the
Setup menu /
submenu
MultiAir fan.
Switch the
MultiAir 1
to
ON
and you will get access to fan speed and fan
adaptation.
Fan level
The volume of convection air is adjustable from AUTO (adapts
automatically according to heating power), over to Level 1 (min) and
level 5 (max).
Fan area
In addition, it is possible to adapt the Multi Air fan speed (AUTO, level
1 to level 5) /- 30% of fan speed.
#13
#13
#25
Summary of Contents for DOMO BACK MultiAir
Page 1: ...Montageanleitung DOMO BACK MultiAir...
Page 2: ......
Page 9: ...Instruction de montage DOMO BACK MultiAir FRAN AIS...
Page 15: ...Istruzioni di montaggio DOMO BACK MultiAir ITALIANO...
Page 21: ...Assembly Instructions DOMO BACK MultiAir ENGLISH...
Page 27: ...Montagehandleiding DOMO BACK MultiAir NEDERLANDS...