Prior to set up

Floor bearing capacity

Ensure that the substructure is capable of bearing the weight of the stove prior 

to set-up.

Note

No modifications may be made to the firing installation. This also leads to loss 

of warranty and guarantee.

Floor protection

A base is recommended (glass, sheet steel or ceramic) if the floor is combustible 

(wood, carpet, etc.). Please observe the respective local regulations and rules.

Flue pipe connection

 

Q

Flue pipes pose a particular source of hazard regarding gas leaks and 

fire. Get the advice of an authorised specialist company for the layout and 

assembly.

 

Q

Please observe the corresponding installation guidelines for walls panelled 

with wood when connecting your flue pipes to the stove.

 

Q

Observe the formation of flue gas (atmospheric inversion) and draughts 

when the weather is unfavourable.

 

Q

Infeed of too little combustion air can lead to smoke in the rooms or to flue 

gas leaks. Hazardous deposits in the stove and chimney may also occur.

 

Q

If flue gas escapes, let the fire burn out and check whether all the air inlet 

openings are free and the flue gas pipes and the stove pipe are clean. If in 

doubt notify the master chimney sweep since draught malfunctions may be 

connected to your chimney.

The correct chimney connection

There are several ways to connect your stove to the chimney, eg:

1) wind break, 2) chimney, 3) inspection opening

For the selection of the connection and to ensure a proper connection between 

the stove and chimney, please read the guide „INSTALLING THE STOVE“ or ask 

your local chimney sweep.

Stoves type 1 (BA 1):

 

Q

Suitable for multiple occupancy. (Note the different country regulations.) 

 

Q

These may only be operated with the combustion chamber door closed.

 

Q

The combustion chamber door is to be kept closed when the stove is not 

in operation.

 

Q

Fouling of the chimney i.e. deposits of highly inflammable materials such as 

soot and tar and subsequently fire in the chimney may occur if the chimney 

is miscalculated and dimensioned wrong.

 

Q

If this occurs, disconnect the mains plug. Phone the fire brigade and get 

yourself and other residents out of harm’s way.

Note

Your pellet stove can be operated room air dependent or room air independent.

ROOM-AIR INDEPENDENT OPERATION:

The stove is certificated for type FC62x of the approval principles for the 

inspection and evaluation of ambient air independent fireplaces specified by 

the Deutsches Institut für Bautechnik (DIBT) (German Institute for Building 

Technology). Thanks to an air-tight configuration of the air supply line and flue 

pipes the stove may be operated in air-tight rooms and in rooms with room-air 

installations (e.g. controlled ventilation and venting systems, extractors etc.).

ROOM-AIR DEPENDENT OPERATION:

In combination with room-air installations (e.g. controlled ventilation and 

venting systems (extractors etc.) it must be ensured that the stove and 

the room air system are monitored and safeguarded mutually (e.g. via 

a differential pressure controller). The combustion air infeed of approx.  

20 m3/h must be ensured. 

Please observe the respective local regulations and rules in consultation with 

your master chimney sweep. For changes after the printing of this manual, we 

can not assume any liability. We reserve the right to change without notice.

Summary of Contents for COMO TOUCH

Page 1: ...Operating Manual COMO TOUCH...

Page 2: ...TIONS 11 Operating comfort 11 Top efficiency lowest emissions 11 Overheating 11 Low temperature shutdown 11 Electrical excess current protection 11 Automatic cleaning cycle 11 Component monitoring 11...

Page 3: ...ng of the burn pot daily 15 Empty the ash drawer 15 Cleaning the door glass 15 Cleaning of painted surfaces 15 Cleaning the flame temperature sensor 15 Cleaning flue pipes 16 Clean flue gas collecting...

Page 4: ...Spare part overview exploded diagram...

Page 5: ...5 EN 4...

Page 6: ...Z30494 Hinge shaft 49 N110461 Double ball catch 50 B12301 Auger 51 N111820 Screw motor stepless 52 N107887 Fuse holder 53 Z34124 Ceramic cover plate left 54 B16263 Heat retaining stone left 55 Z34126...

Page 7: ...s 4 9 Exhaust temperature C 175 3 Chimney draft requirement Pa 0 The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to...

Page 8: ...y Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q When your stove is burning the use of highly inflammable and explosive materials in the same or adjace...

Page 9: ...or ask your local chimney sweep Stoves type 1 BA 1 Q Suitable for multiple occupancy Note the different country regulations Q These may only be operated with the combustion chamber door closed Q The...

Page 10: ...with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list of monitored fuel ma...

Page 11: ...increased every hour for a short period to blow ash from the burn pot increasing the operational safety The status indicator CLEANING appears on the display Only for stoves with turning grids Every 6...

Page 12: ...oor for regular inspection and cleaning must be present The flue pipe connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrounding air Thi...

Page 13: ...r front panel by simply lifting The front panel is simply hooked Remove the convection fins by lifting slightly The convection fins are only suspended Remove the 2 vertical hexagonal screws used to at...

Page 14: ...ntrol of your stove is to be assumed by an external room thermostat you have to connect your external room thermostat 1 instead of the standard integrated cable bridge 2 The connected room thermostat...

Page 15: ...ings Vacuum clean any dust deposits from the convection air openings at regular intervals The stove should be cleaned thoroughly prior to the start of the heating season to prevent excess odour Combus...

Page 16: ...ended Open and remove the wing nut which serves to secure the firebox lid For ease of disassembly you should hold up the screw through the combustion chamber Open the screw of the sensor tube with an...

Page 17: ...Clean flue gas fan housing The flue gas fan and the flue pipe connection should be cleaned at least 2 times a year or after about 700 kg of pellets To inspect and clean the flue gas fan the back wall...

Page 18: ...ompany Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in phase a...

Page 19: ...the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in the pu...

Page 20: ...tware version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present Function checked Check of system components C...

Page 21: ...ser and installation manuals valid at the time of purchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to...

Page 22: ......

Page 23: ...23 EN 22...

Page 24: ...dorf Austria M llerviertel 20 Telefon 43 7582 686 41 Fax DW 43 E Mail verkauf rika at RIKA AT Technical and design changes as well as typesetting and printing errors reserved 2016 RIKA Innovative Ofen...

Reviews: