background image

 

 

Rack Mount Kit  

 

   

 

 

DS8000-R Series Rack Mount Kit 

RM1011&RM1012 

 
 
 
 
 
 
 
 
 

 

 

 
 
 

Aug. 2020 

RIGOL

 TECHNOLOGIES CO., LTD.

Summary of Contents for RM1011

Page 1: ...Rack Mount Kit DS8000 R Series Rack Mount Kit RM1011 RM1012 Aug 2020 RIGOL TECHNOLOGIES CO LTD ...

Page 2: ...ion in this publication is subject to change without notice RIGOL shall not be liable for either incidental or consequential losses in connection with the furnishing use or performance of this manual as well as any information contained Any part of this document is forbidden to be copied photocopied or rearranged without prior written approval of RIGOL Product Certification RIGOL guarantees that t...

Page 3: ...Installation Guide RIGOL 2 E mail service rigol com Website www rigol com ...

Page 4: ... of important data Safety Terms on the Product DANGER It calls attention to an operation if not correctly performed could result in injury or hazard immediately WARNING It calls attention to an operation if not correctly performed could result in potential injury or hazard CAUTION It calls attention to an operation if not correctly performed could result in damage to the product or other devices c...

Page 5: ...oscilloscope far away from heat sources Rack Mount Installation for a Single Instrument Recommended Kit Part Checklist Table 1 RM1011 Part List No Name Qty Description 1 Front Bezel 1 2 Rear Bezel 1 3 Rear Hanging Ear 1 4 Left Side Beam 1 5 Right Side Beam 1 6 M4 Screw 8 M4x8 Phillips Pan Head Screw 7 M6 Screw 8 M6x16 Phillips Pan Head Screw 8 M6 Nut 8 M6 Square Lock Cage Nut Table 2 DS8000 R Comp...

Page 6: ...Installation Guide RIGOL 5 4 3 5 7 6 2 8 1 10 9 12 11 12 6 7 8 Installation Tool The PH2 Phillips screwdriver T10 torx screwdriver and T20 torx screwdriver are recommended ...

Page 7: ...ectly please ensure that the following requirements are met The cabinet must be a standard 19 inch one The available height of the cabinet should be at least 1U 44 mm The depth of the cabinet should be at least 600 mm The dimensions of the rack are as shown below 465 44 483 32 577 569 Unit mm ...

Page 8: ...the instrument or an installation failure 1 Remove the four pads 2 Remove three M3x6 torx flat head countersunk screws that secure the hanging ear of the instrument at the right side of the front panel Then remove two M4x8 torx pan head screws that secure the handle You only need to remove the hanging ear at one side and keep the hanging ear at the other side unremoved ...

Page 9: ... bezel 4 Attach the front bezel to the right side of the front panel then secure the bezel by using three M3x6 torx flat head countersunk screws 5 Secure the left and right side beams to the two sides of the rear panel by using the available M3x6 torx flat head countersunk screws on the instrument ...

Page 10: ...net by using four M6x16 phillips pan head screws and four M6 square lock cage nuts 7 Use two M6x16 phillips pan head screws and two M6 square lock cage nuts to secure the rear hanging ear to the cabinet Then use four M4x8 phillips pan head screws to secure the left side beam to the rear hanging ear ...

Page 11: ...and two M6 square lock cage nuts to secure the rear bezel to the rack Then use four M4x8 phillips pan head screws to secure the right side beam to the rear bezel 9 The following figure shows the front view of the successful rack mount installation for one instrument End ...

Page 12: ...eft Side Beam 1 3 Right Side Beam 1 4 Connecting Plate 4 5 M4 Screw 8 M4x8 Phillips Pan Head Screw 6 M6 Screw 8 M6x16 Phillips Pan Head Screw 7 M6 Nut 8 M6 Square Lock Cage Nut Table 4 DS8000 R Components available to be disassembled for rack mount installation No Name Qty Description 8 Hanging Ear 2 9 Handle 2 10 M3 Screw 18 M3x6 Torx Flat Head Countersunk Screw ...

Page 13: ...Installation Guide RIGOL 12 2 6 4 5 1 3 8 8 7 9 10 10 5 6 7 Installation Tool The PH2 Phillips screwdriver and T10 torx screwdriver are recommended ...

Page 14: ...ectly please ensure that the following requirements are met The cabinet must be a standard 19 inch one The available height of the cabinet should be at least 1U 44 mm The depth of the cabinet should be at least 600 mm The dimensions of the rack are as shown below 483 465 32 44 569 577 Unit mm ...

Page 15: ...lation might cause damage to the instrument or an installation failure 1 Remove the four pads 2 Remove six M3x6 torx flat head countersunk screws that secure the two hanging ears at a different side of each instrument You only need to remove the hanging ear at one side for each instrument and keep the hanging ear at the other side unremoved ...

Page 16: ...orx flat head countersunk screws on the instrument 4 Secure the left side beam to the left side of the rear panel of Instrument A and secure the right side beam to the right side of the rear panel of Instrument B by using the existing M3x6 torx flat head countersunk screws on the instrument Instrument A Instrument B ...

Page 17: ...e lock cage nuts 6 Use four M6x16 phillips pan head screws and four M6 square lock cage nuts to secure the two rear hanging ears to the rack Then use four M4x8 phillips pan head screws to secure the left side beam of Instrument A to the rear hanging ear use four M4x8 phillips pan head screws to secure the right side beam of Instrument B to another rear hanging ear ...

Page 18: ...Installation Guide RIGOL 17 7 The following figure shows the front view of the successful rack mount installation for two instruments End Instrument B Instrument A ...

Page 19: ...hout condensation 40 to 50 45 RH without condensation Non operating Below 65 90 RH without condensation Ventilation Requirement This oscilloscope uses a fan to force cooling Please make sure that the air intake and exhaust areas are free from obstructions and have free air When using it in rack setting keep at least 1 m clearance from the surroundings of the cabinet When running in the cabinet kee...

Page 20: ...Installation Guide RIGOL 19 Cabinet Diagram ...

Reviews: