RIGOL 

 

  Quick Guide for DG5000

 

14 

User Interface 

 

The user interface is usually shown in two modes which are “Parameter” and 
“Graphic”. The illustration given here will take the “Graphic” mode of the 
Dual-Channel Model for example. 

 

Parameter Mode 

 

Figure 11 User Interface (Parameter Mode) 

 

Graph Mode 

In parameter mode, toggle the “Display Switch” 

 

at the upper right of the screen 

to switch to the Graphic Mode. 

2.Current 

Function

1.Status 

Bar

8.Menu Softkey

7.Output Cfg

6.Wave Disp

4.Freq Disp

3.Channel Label

5.Ampl Disp

 

Figure 12 User Interface (Graphic Mode) 

Summary of Contents for DG5000 Series

Page 1: ...RIGOL Quick Guide DG5000 Series Function Arbitrary Waveform Generator Oct 2010 RIGOL Technologies Inc...

Page 2: ......

Page 3: ...corresponding material RIGOL shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any information...

Page 4: ...the earth terminal of power cord to the Protective Earth terminal before any inputs or outputs Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markers on the instru...

Page 5: ...nterior of the device or electric shock please do not operate in a humid environment Do Not Operate in an Explosive Atmosphere In order to avoid damages to the device or personal injuries it is import...

Page 6: ...that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER indicates an injury or hazard may immediately happen WARNING indicates a...

Page 7: ...form the following steps 1 Disconnect the instrument from all power sources 2 Clean the loose dust on the outside of the instrument with a lint free cloth with a mild detergent and water When clean th...

Page 8: ...nd batteries Product End of Life Handling The equipment may contain substances that could be harmful to the environment or human health In order to avoid release of such substances into the environmen...

Page 9: ...VI Quick Start 1 General Inspection 1 Handle Adjustment 2 Appearance and Dimensions 3 Front Panel 4 Rear Panel 10 Power on the Generator 13 User Interface 14 Parameter Mode 14 Graph Mode 14 To Rack Mo...

Page 10: ......

Page 11: ...ping please contact your shipper and carrier for compensation RIGOL will provide no free repair or replacement 2 Inspect the instrument In case of any mechanical damage or defect or if the instrument...

Page 12: ...ment To adjust the handle position of the instrument please grip the handle by sides and pull it outward Then rotate the handle to the desired position The operating method is shown below Adjusting th...

Page 13: ...RIGOL Quick Guide for DG5000 3 Appearance and Dimensions Front Elevation Unit mm Side Elevation Unit mm...

Page 14: ...Numeric Keyboard 24 CH1 Output Control 25 CH2 Output Control 27 CH2 Output 26 CH1 Output 23 Channel Toggle 1 Power Key 2 USB Host 3 LCD 4 Display Switch 14 Modulation 15 Sweep 16 Burst 20 Knob 17 Sto...

Page 15: ...s used to display the current function menu and parameters setting system state and prompt messages 4 Display Switch For dual channel model Switch between Parameter Graph display mode For single chann...

Page 16: ...MHz Provide two output modes Normal and Play Generate 10 built in waveforms DC Sinc Exponential Rise Exponential Fall ECG Gauss Haversine Lorentz Pulse and Dual Tone generate arbitrary waveforms from...

Page 17: ...N Cycle Infinite and Gated Noise can also be used to generate Gated burst When the function is enabled the backlight of the button turns on In remote mode press this button to switch to local mode 17...

Page 18: ...model not available 24 CH1 Output Control For dual channel model control the output of CH1 When the output function enables the backlight of the button goes on For single channel model trigger Sweep a...

Page 19: ...nnel will take effect once any of the following conditions is met Amplitude setting in the generator is greater than 2 Vpp the input voltage is greater than 12 1 V 0 1 V and frequency is lower than 10...

Page 20: ...t 2 CH1 Mod I Signal In 3 CH2 Mod I Signal In 4 CH1 Q Signal In 5 CH2 Q Signal In 6 CH1 Sync Out 7 CH2 Sync Out 8 CH1 ExtTrig In 9 CH2 ExtTrig In 10 10MHz In 11 10MHz Out 12 LAN 13 USB Device 14 GPIB...

Page 21: ...0 k 4 CH1 Q Signal In Q1 This SMB connector accepts an external Analog Quadrature Phase Q modulation signal to be used in CH1 s modulation The nominal input impedance is 10 k 5 CH2 Q Signal In Q2 This...

Page 22: ...ocal network for remote control An integrated testing system may be built as the generator conforms to the LXI C class standard of LAN based instrument control 20 USB Device Through this interface the...

Page 23: ...following steps 1 Turn on the power of the instrument Turn on the power switch at the rear panel of the instrument WARNING To avoid electric shock make sure the instrument has been properly grounded 2...

Page 24: ...aphic mode of the Dual Channel Model for example Parameter Mode Figure 11 User Interface Parameter Mode Graph Mode In parameter mode toggle the Display Switch at the upper right of the screen to switc...

Page 25: ...key Freq and use the numeric keyboard or knob to modify this parameter The parameter that can be modified currently will be highlighted 5 Amplitude Display Display the current waveform amplitude in ea...

Page 26: ...rts List NO Name Qty Part Number Description 1 1 Front Panel 1 RM DG 5 01 1 2 Support Board 1 RM DG 5 02 1 3 Left Plate 1 RM DG 5 03 1 4 Right Plate 1 RM DG 5 04 1 5 Fixed Figure 2 RM DG 5 05 2 1 M4 S...

Page 27: ...RIGOL Quick Guide for DG5000 17 2 1 2 2 2 3 Installation Tool PH2 Phillips Screwdriver recommended...

Page 28: ...the machine cabinet in which the instrument is mounted Dimension of the machine cabinet must be standard 19 inch At least 3U 133 5 mm space should be provided by the machine cabinet The depth inside t...

Page 29: ...installed in rack incorrectly if the installation is not proper 1 Remove the handle please grip the handle by sides pull it outward and then upward 2 Install the right and left plates align the deten...

Page 30: ...rument align the protection pads of the instrument with the corresponding holes and then place it on the Support Board 4 Fixed the instrument Fasten the instrument tightly on the Support Board with tw...

Page 31: ...and fix them with four M4 screws 6 Load into the machine cabinet mount the rack fixed with instrument into a standard 19 inch machine cabinet with four M6 screws and square nuts 7 Post installation n...

Page 32: ...rity Lock Use a security lock to lock your generator in a desired location As shown in the picture below align the lock with the lock hole on the generator and insert the lock Turn the key clockwise t...

Page 33: ...on help 1 View the last displayed message 2 View error queue of the remote commands 3 Get the help information of a key 4 Generate a basic waveform 5 Generate an arbitrary waveform 6 Generate a modula...

Page 34: ...t does not work correctly contact RIGOL for our service 2 The settings are correct but no waveform is generated 1 Check if the Signal Line is correctly connected to the Output terminal 2 Check if the...