If the table is unresponsive, uneven, or not functioning properly, perform a manual reset.
User settings are not reset in this process.
There are three methods to reset a workstation:
Reset Method A
1. Clear all obstructions from the travel path of the workstation
2. Disconnect the power to the control box for 30 seconds.
3. Reconnect the power
4. Press and hold the
until the workstation has reached its lowest possible position.
Reset Method B (4 button programmable switch required)
1. Clear all obstructions from the travel path of the workstation
2. Quickly press
UP
+
UP
+
UP
+
UP
to enter the menu mode.
3.
P01
is displayed
and you will hear a musical tone.
4. Press the
to navigate the menu.
5. Navigate to the
P09
display
6. Press the
button to enter or accept
7. Press and hold the
until the workstation has reached its lowest possible position.
The workstation is now ready to operate
Reset Method C - 2 Button Switch
1. Clear all obstructions from the travel path of the workstation
2. Quickly press
UP
+
UP
+
UP
+
UP
to enter the menu mode.
3. You will hear a musical tone.
4. Press
UP
+
UP
+
UP
+
5. You will reach the limit adjustment menu and hear four musical tones.
6. Press and hold the
until the workstation has reached its lowest possible position.
The reference is re-calibrated, the table should be leveled and the height indication should be correct.
Mechanical Reset Mode