WARNING! 

z

 

The Hush Feature is for your convenience only and will not correct a CO problem. Always check your home for a 

potential problem after any alarm. Failure to do so can result in injury or death. 

z

 

NEVER remove the batteries from your CO Alarm to silence the horn. Use the hush feature. Removing the batteries 

removes your protection! See “If Your CO Alarm Sounds” for details on responding to an alarm. 

The Hush Feature is intended to temporarily silence your CO Alarm’s alarm horn while you correct the problem—it will not correct a 

CO problem. While the alarm is silenced it will continue to monitor the air for CO. 

When CO reaches alarm levels the alarm will sound— repeating horn pattern: 4 beeps, a pause, 4 beeps, etc. Press and hold the 

Test/Silence button until the horn is silent. The initial Silence cycle will last approximately 4 minutes. 

NOTE: 

After initial 4-minute Silence cycle, the CO Alarm re-evaluates present CO levels and responds accordingly. If CO levels 

remain potentially dangerous—or start rising higher—the horn will start sounding again. 

For the wireless devices in the same ID, when the devices are in 

Local alarm

 or 

Remote alarm status

 (refer to 

TABLE2

), 

Triggering the Hush function will lead all the devices to be in Hush Status.

 

 

LOCATE FEATURE 

When the devices alarming for detecting carbon monoxide, users can find the initial point through the Locate Feature :   

Find any one of the alarming device

Local Alarm or Remote Alarm

,    press the Test/Hush button and release it in 2 seconds. Then 

the Locate Feature will be triggered. After triggering Locate Feature, all the alarming devices will be stop sound, except the initial 

device which is detecting carbon monoxide signal keeps alarming until carbon monoxide signal goes off. 

REGULAR MAINTENANCE 

WARNING! 

Use only the replacement batteries listed below. The unit may not operate properly with other batteries. Never use 

rechargeable batteries since they may not provide a constant charge. 

This unit has been designed to be as maintenance-free as possible, but there are a few simple things you must do to keep it working 

properly: 

z

 

Test it every week using the Test button. 

z

 

Vacuum the CO Alarm cover once a month, using the soft brush attachment. Never use water, cleaners, or solvents, since 

these may damage the unit. Test the CO Alarm again after vacuuming. 

z

 

Replace the batteries when the CO Alarm “chirps” about every minute (the low battery warning). 

The low battery warning should last for 30 days, but you should replace the battery immediately to continue your protection. 

The unit requires one standard 9V battery. The following batteries are acceptable as replacements:   

Golden Power #6F22; New Leader #6F22; Gold Peak #6F22; Eveready #522, #1222.; Golden Power G6F22; Golden Power 

GL6F22A 

IMPORTANT! 

Actual battery service life depends on the Alarm and the environment in which it is installed. All the batteries specified above are 

acceptable replacement batteries for this unit. Regardless of the manufacturer’s suggested battery life, 

you MUST replace the 

battery immediately once the unit starts “chirping” (the “low battery warning”).

 

Summary of Contents for VST-WC588IH

Page 1: ...et after CO is clear SPECIFICATION Detection Type Electrochemical CO sensor Power Source 9V 6F22 Battery Working frequency 868MHz Emission distance 60m open space Standby Current 25uA max Alarm Current 40mA max CO Alarm Level 50ppm Between 60 90 min 100ppm Between 10 40 min 300ppm 3min Alarm Sound Level 85 Decibels at 1 meter Operation Temperature 4 to 40 Ambient Humidity 15 to 90 Relative Humidit...

Page 2: ...neous operation of several fuel burning appliances competing for limited internal air z Vent pipe connections vibrating loose from clothes dryers furnaces or water heaters z Obstructions in or unconventional vent pipe designs which can amplify the above situations z Extended operation of unvented fuel burning devices range oven fireplace etc z Temperature inversions which can trap exhaust gases ne...

Page 3: ...rage is recommended Place CO Alarms on each level of the home CO Alarms may not be heard The alarm horn loudness meets or exceeds current EN standards of 85 dB at 1 meter However if the CO Alarm is installed outside the bedroom it may not wake up a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages This is especially true if the door is closed or only partly ...

Page 4: ...east one CO Alarm on each level of the home z For added protection install an additional CO Alarm at least 20 feet 6 meters away from the furnace or fuel burning heat source In Mobile Homes z Install CO Alarms on inside walls ONLY Uninsulated outside walls and roofs of mobile homes often transfer heat and cold from outdoors The Alarm should be located at least 152 mm 6 inches from all exterior wal...

Page 5: ...ovide adequate protection in non residential applications HOW TO INSTALL THIS ALARM This CO Alarm is designed to be mounted on any standard wiring junction box up to a 4 inch 10 cm size on either the ceiling or wall if allowed by local codes Read Where to Install This Alarm and Where This Alarm Should Not Be Installed before you begin installation WARNING Make sure the Alarm is not receiving exces...

Page 6: ...ission signal and gives alarm it will emit signal immediately to drive other units alarming It is also a relay station of wireless signal to form a wireless alarm network with relay transmit The emit distance is 30m in house area for the repeater setting the right diagram is for your reference FOLLOW THE ID SETUP STEPS 1 Remove the battery 2 Press and hold the button for a minimum of 10 seconds 3 ...

Page 7: ...ps carbon monoxide is detected by the device and trigger the device to alarm Remote Alarm Off Off Alarming sound The device is triggered to alarm by receiving the wireless alarm signal from other device Locate Alarm Flashing accompany with alarming sound Off 4 beeps pause 4 beeps Only Local alarm can be in this state but it cannot transmit the alarm signal out Hush State 1 flash every 10 seconds O...

Page 8: ...ediately If the CO Alarm is not working properly it cannot alert you to a problem z DO NOT stand close to the Alarm when the horn is sounding Exposure at close range may be harmful to your hearing When testing step away when horn starts sounding Press the test button and release it in 2 seconds The alarm horn will sound 4 beeps a pause then 4 beeps The ALARM RED light will flash The other devices ...

Page 9: ...Alarm press the Test Hush button and release it in 2 seconds Then the Locate Feature will be triggered After triggering Locate Feature all the alarming devices will be stop sound except the initial device which is detecting carbon monoxide signal keeps alarming until carbon monoxide signal goes off REGULAR MAINTENANCE WARNING Use only the replacement batteries listed below The unit may not operate...

Page 10: ...date on the label of unit on back side IF YOUR CO ALARM SOUNDS WARNING Actuation of your CO Alarm indicates the presence of carbon monoxide CO which can kill you In other words when your CO Alarm sounds you must not ignore it IF THE ALARM SIGNAL SOUNDS z Find any one of the alarming device press the Test Hush button and release it in 2 seconds Triggering the Locate function of the alarming devices...

Page 11: ...pen it slowly Don t open a hot door Keep doors and windows closed unless you must escape through them z Cover your nose and mouth with a cloth preferably damp Take short shallow breaths z Meet at your planned meeting place outside your home and do a head count to make sure everybody got out safely z Call the Fire Department as soon as possible from outside Give your address then your name z Never ...

Page 12: ...to manufacturer for replacement The horn sounds 2 quick chirps following with 1 long chirp Malfunction signal CO Alarm needs to be replaced CO Alarms under warranty should be returned to manufacturer for replacement For your records please record Date Purchased Where Purchased Data Installed Replacement data is 5 years after installation NOTE End of Life Signal Once the unit reaches the end of its...

Reviews: