Rev. 1 of 15.04.16

No. 00216

The communication quality with the CP at the place of the detector installation 

should provide reliable message transmission (See Cl. 9 Communication Quality 
Appraisal).

8 LED Indication

Table 3

Detector Status

LED Indication

LED Status

Operation mode

«Binding»

Green LED indicator blinks  

intermittently

«Alarm»*

LED indicator lights red for at 

least 0.5 sec

If indication is 

enabled

«Identification»

LED indicators blinks alternately 

red and green at 1 Hz frequency

by a command 

from the CP

«Connection quality»

See Sect. «Communication Quality Appraisal»

Binding procedure 

completed

LED indicator lights red for 2 sec

*) — Alarm indication is deactivated in 15 minutes after the detector cover is 
closed and activated after it has been opened or at a command from the CP.

10 Installation

10.1  Assemble the supplied swivel bracket:

Figure 3 – The Swivel Bracket Design

Plug

Nut Sphere

Swivel 

bracket

Screw

- place the screw-nut into the 
sphere recess; 
- enclose the swivel bracket 
base into the sphere;
- insert the plug into the swivel 
bracket base.

10.2  Install and fix the assembled swivel bracket to the wall/ceiling at the 

chosen place of installation. The swivel bracket case should be used as a 
pattern for marking fixation holes on the installation surface.

10.3 Fix the base to the installed swivel bracket by means of mounting screw 

passing it through the one of the openable holes (2).

10.4 After fixing the base on the swivel bracket pack off the opening (2) by 

the plastic potting compound (supplied).

10.5 Put the PCB on it’s place, fix it by latch and screw (8).

11 Adjustment

11.1 The detector adjustment includes the detection zone position alignment 

and sensitivity level choosing. 

11.2 To determine the limits of the detection zone, start movement across the 

detection zone at a speed of 0.5 – 1 m/sec 60 sec after switching the detector 
in «Activated» mode.  

11.3 Upon every detection of a movement, the detector transmits the «Alarm» 

message via radio communication. During the first 15 min after the cover 
closing, the «Alarm» message is duplicated by the LED indicator switching red 
in a short-run.

11.4 Changing of the detection zone position is fulfilled by the detector 

rotation on the swivel bracket.

«Alarm» message generation upon the motion absence within the detection 

zone limits indicates a high - interference environment. In this case, it is 
recommended to narrow the detector sensitivity. Removal of «SENS.HIGH» 
jumper reduces the detector detection range from 12 up to 8 m, but in the 
same time it increases the detector interference protection. After sensitivity 
adjustment, check the detection zone limits.

The «Alarm» indication is switched off automatically in 15 min after the 

detector case closing.

If it is necessary to continue the adjustment, put off the cover, and after put 

it on it’s place. 

Modes of operation
The detector provides three modes of operation: «Deactivated», «Activated» 

and «Identification». The modes changeover is ensured by the relevant command 
from the CP.

Under operation in the «Deactivated» mode, the detector transmits the 

«Alarm» message immediately with contemporary starting unscheduled radio 
communication session. «Norm» message is transmitted during regular radio 
communication sessions.

Under operation in the «Activated» mode, the detector immediately transmits 

messages  about  it’s  state  changing  with  contemporary  starting  unscheduled 
radio communication session.

Under the «Identification» mode, started by the relevant command from 

the CP, the LED indicator blinks red and green alternately (See Table 3). The 
«Identification» mode allows to locate the detector with the preset address.

12 Storage and Transportation

12.1 The Detectors in original package may be transported by any means 

of transportation in closed vehicles over any distances in compliance with the 
existing shipping rules concerning the respective means of transportation.

12.2 Storage conditions of the Detectors: storage premises should not 

contain any current-conducting dust, acid and alkali fumes, as well as corrosive 
gases or those destroying insulation.

13 Manufacturer’s Guarantees

13.1 The manufacturer guarantees conformity of the Detector to the Technical 

Specifications requirements provided the transportation, storage, installation 
and operation conditions are observed.

13.2 The guaranteed shelf life of the Detector is 63 months since the date 

of manufacture.

13.3 The guaranteed useful life is 60 months since the day of putting into 

operation within the guaranteed shelf life.

13.4 The Detectors that are found non-conforming to the Technical 

Specifications requirements shall be repaired by the manufacturer, provided the 
installation and operation rules have been complied.

Note

 – Warranty obligations are not applied to the power supply batteries.

14 Acceptance and Packing Certificate

Wireless security passive infrared wide-angle detector «Pyrone-8-RK», 

batch number________________________, 
has been manufactured in compliance with the active technical documentation, 

classified as fit for operation and packed by «RIELTA» JSC.

Person in charge of acceptance and packing

QC representative_________________    __________________.

day, year, month

Made in Russia   

               

«RIELTA» JSC, www.rielta.com,
Chapaeva Str. 17, Saint Petersburg, Russia, 197101, [email protected],
Tel./fax. +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected]

.