2.11 Emissions
Linea ONE
NOx (max-min)
30 - 15 p.p.m.
CO (max-min)
150 - 10 p.p.m.
CO
2
(max-min)
9,0 - 9,5 %
CO/CO
2
ratio (max)
0,0017 to 1
CO/CO
2
ratio (min)
0,0001 to 1
Ref. Condition 15 °C, 1013,25 mbar, dry gas
NOTE: L.P.G. data refer to section 10
2.13 PUMP DUTY
Linea ONE boilers are fitted with a variable speed circulation unit
that is already connected up in terms of plumbing and electrics, and
the usable performance it provides is shown in the graph.
The boilers are fitted with an anti-blocking system that starts an
operating cycle every 24 hours when not used, irrespective of the
position of the function selector.
The “anti-blocking” function is only active when the electrical power
supply to the boiler is on.
Operating the circulation system without any water is strictly forbid-
den.
VARIABLE SPEED CIRCULATION UNIT
The modulating circulating function is only active for the heating func-
tion. When switching the three ways on the plate heat exchanger,
the circulation unit is set at maximum speed. The modulating
circulation function applies only to the boiler circulation unit and
not to circulation units on any external devices connected to it (e.g.
booster circulation unit).
Any of 4 operating modes can be chosen, depending on situations
and the type of plant.
By accessing parameter 90 in the technical menu, one of the fol-
lowing possibilities can be chosen:
2.12 Range rated (parameter 23)
Input
fan speed (rpm)
CO (ppm) - less than
3,8 kW
1200
10
6 kW
1750
20
8 kW
2050
28
10 kW
2300
35
12 kW
2600
45
14 kW
2850
55
16 kW
3100
65
18 kW
3350
75
20 kW
3650
85
22 kW
3850
97
24 kW
4150
108
26 kW
4400
120
28 kW
4650
130
30 kW
5000
150
Seasonal space heating energy efficiency class
A
Water heating energy efficiency class
A
Parameter
Symbol
Value
Unit
Parameter
Symbol
Value
Unit
Rated heat output
Prated
29
kW
Seasonal space heating
energy efficiency
η
s
93
%
For boiler space heaters and boiler combination heaters: useful heat
output
For boiler space heaters and boiler combination heaters: useful efficiency
At rated heat output and high-temperature
regime (*)
P4
29,3
kW
At rated heat output and high-temperature
regime (*)
η
4
88,2
%
At 30% of rated heat output and low-tem-
perature regime (**)
P1
9,8
kW
At 30% of rated heat output and low-tem-
perature regime (**)
η
1
98,2
%
Auxiliary electricity consumption
Other parameters
At full load
elmax
44,0
W
Stand-by heat loss
Pstby
44,0
W
At part load
elmin
18,5
W
Pilot flame energy consumption
Pign
-
W
In Stand-by mode
PSB
7,6
W
Annual energy consumption
QHE
51
GJ
Sound power level, indoors
LWA
55
dB
Emissions of nitrogen oxides
NOx
19
mg/
kWh
For combination heaters:
Declared load profile
XL
Water heating energy efficiency
η
wh
83
%
Daily electricity consumption
Qelec
0,290
kWh
Daily fuel consumption
Qfuel
23,070
kWh
Annual electricity consumption
AEC
64
kWh
Annual fuel consumption
AFC
17
GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater
inlet).
Summary of Contents for Vokera Linea ONE
Page 39: ...37 ...