3342
3
GB
2.
TECHNICAL DATA
2.1
TECHNICAL DATA
2.2
GAS CATEGORY
2.3
OVERALL DIMENSIONS
Model
RX 90 S/PV
Thermal power
(1)
18/91 kW - 15,480/78,260 Kcal/h
Natural gas -
(Family 2)
G20
Net heat value: 9.45 kWh/Sm
3
= 8,100 kcal/Sm
3
- Pressure 10 - 30 mbar
G25
Net heat value: 8.125 kWh/Sm
3
= 7,000 kcal/Sm
3
- Pressure 10 - 30 mbar
Power supply
Single-phase,
~
50/60Hz 220/230 V
Ø
10%
Motor
max. 6000 rpm - 50/60Hz
Ignition transformer
Primary 230V - 0.2A
√
Secondary 8 kV - 12 mA
(1) Reference conditions:
Air temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
COUNTRY
AT - CH - CZ - DK - EE - ES - FI - GB - GR
IE - IS - IT - LT - LV - NO - PT - SE - SI - SK
FR
BE
DE - LU - PL
GAS CATEGORY
I
2H
I
2Er
I
2E(R)B
I
2E
GAS
PRESSURE
20 mbar
20/25 mbar
20/25 mbar
20 mbar
D7579
284
242
275
578
356
67