3328
8
GB
BCC (CHIP CARD)
The
B
urner
C
hip
C
ard (BCC) is a card to update the parameters of a burner control easily without a PC.
N.
Safety parameters
Min.
Max.
OEM-preset
Value
1
Prepurge time
0.2
51.0
20.0
Seconds
2
Safety time
0.1
10.0
3.0
Seconds
3
Flame stabilization time
0.1
25.5
5.0
Seconds
4
Start-up attempts
1
5
2
Number
5
Postpurge time
0.2
51.0
5
Seconds
6
Pre-Ignition time
0.1
25.5
1.0
Seconds
7
Ignition reduction time
0.1
25.5
0.5
Seconds
8
Postpurge speed
780
9960
3600
R/min
9
Maximum speed
780
9960
6660
R/min
10
Checktime V1
0.1
25.5
1
Seconds
11
Pulsetime V1
0.1
25.5
2
Seconds
12
Checktime V2
0.1
25.5
2.5
Seconds
13
Pulsetime V2
0.1
25.5
2
Seconds
14
Min. limit max. fan speed
780
9960
3660
Rot/min
15
Max. limit max. fan speed
780
9960
6420
Rot/min
16
Fan speed feed back
1
4
2
Impulses/Rot
17
Sample rate speed control
1
2
2
Hz
18
No APS
0
1
1
-
19
Permanent APS check
0
1
0
-
20
No fan speed feedback
0
1
0
-
21
No GPS
0
1
0
-
22
Restart
0
1
0
-
23
Gas valve check
0
1
0
-
24
Tightness control
0
1
1
-
SAFETY PARAMETERS