GENERAL INFORMATION
GENERAL INFORMATION
2
PRECAUTIONS
The operation of any appliance that uses electrical power de-
mands that a number of fundamental safety precautions be re-
spected. In particular:
0
Never attempt to install the system without using suitable
personal protection equipment and without following all
applicable occupational safety standards.
0
It is forbidden to touch the device while barefoot or with
wet or moist body parts.
0
It is forbidden to perform any technical or cleaning opera-
tions before having disconnected the device from its elec-
trical power supply, by setting the system's main switch to
"off".
0
It is forbidden to pull, detach, or twist the electrical cables
protruding from the device, even if it is disconnected from
its electrical power supply.
0
Do not expose the storage cylinder to the elements. It is not
designed for use outdoors.
0
If solar plant pressure decreases, it is forbidden to top up
with only water as there is a danger of freezing and over-
heating.
0
Do not use connections or safety devices or fittings (expan-
sion vessels, pipes, insulation) that are not specifically de-
signed and tested for use in solar water heating systems.
0
Do not allow children or infirm persons to operate the sys-
tem unsupervised.
0
Do not dispose of packaging material into the environment,
or leave it within the reach of children, since it can become
a potential hazard. Dispose of packaging material in com-
pliance with applicable legislation.
3
DESCRIPTION OF THE APPLIANCE
The solar station
RSS
allows transferring sun power from collec-
tors to a storage system.
The solar station
R
is enclosed in an EPP (Polypropylene foam)
insulating casing and is designed to perform:
− system flushing
− system filling and emptying
− circulator removal.
The key components are:
− high-efficiency circulator with variable speed (already
hard-wired)
− shut-off valves as non-return valves
− thermometers
− pressure gauge
− fitting for connection to a solar expansion tank
− suitable safety device, as indicated in paragraph "Safety
and control devices".
Version MRS includes a solar regulator and temperature probes
as standard (to be connected). Version MR includes a terminal
strip for interface connection to an external regulator able to
manage one PWM pump.
9
The integrated circulator can be managed only through
PWM signal and does not need a flow control. Therefore,
to choose the proper solar regulator to match version MR
please refer to paragraph "Electric connections and wiring
diagrams”.
4
SAFETY AND CONTROL DEVICES
Solar station safety and setting are achieved thanks to:
− Safety valve with trigger pressure set at 6 bar;
− Solar Regulator (if equipped) for circulator management/
control. Manages 9 system diagrams that can be select-
ed. Refer to the specific manual for further details.
5
IDENTIFICATION
The solar stations by
R
can be identified by:
Serial number plate
This specifies the serial number and model.
Cod. :
Via Ing. Pilade Riello 7 - 37045 Legnago (VR) - Italia
RIELLO S.p.A.
TqelRI100
Serial N.° :
Mod. :
MAX
W
IP
Pmax
bar
Made in Italy
9
If these plates or any other means of clearly identifying
the product are defaced, removed or lost, proper instal-
lation and servicing may be rendered difficult.
In case of loss, request a duplicate to
R
Technical Assistance
Service.