Riello RSS MR Installation And Maintenance Manual Download Page 2

2

GENERAL INFORMATION

This manual, Code 20124605 - Rev. 2 (10/2017) 

comprises 12 pages.

GENERAL INFORMATION

RANGE

MODEL

CODE

RSS MRS

20116166

RSS MR

20116167

Dear heating engineer,

We would like to congratulate you on having recommended a 

R

 solar station unit: a modern product that's capable of en-

suring a high degree of reliability, efficiency, quality and safety.

While your technical skills and knowledge will certainly be more 

than sufficient, this booklet contains all the information that 

we have deemed necessary for the device's correct and easy in-

stallation.

Thank you again, and keep up the good work,

Riello S.p.A.

CONTENTS

ENGLISH

GENERAL SAFETY INFORMATION

 

9

Check that the product is complete, undamaged and as or-

dered as soon as you receive it. Report any discrepancies or 

damage to the 

R

 dealer who sold it.

 

9

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to the 

highest standards in compliance with the instructions pro-

vided by 

R

 in this instruction manual, and that it con-

forms to all applicable laws and standards.

 

9

This product must only be used for the purpose for which it 

is designed and made, as specified by 

R

R

 declines 

all responsibility, contractual or other, for damage to prop-

erty or injury to persons or animals caused by improper in-

stallation, adjustment, maintenance or use.

 

9

The product must be serviced at least once a year. Servicing 

must be arranged in advance with the 

R

 Technical Assis-

tance Service.

 

9

All servicing and repairs must be performed by a qualified 

heating engineer.

 

9

This instruction manual is an integral part of the product. It 

must be kept safe and must ALWAYS accompany the product, 

even if it is sold to another owner or transferred to another 

user or to another installation. If you lose this manual, or-

der a replacement immediately. Keep the product purchase 

documents to be presented to the 

R

 authorised Technical 

Assistance Service to request a service call under warranty.

 

9

Size the solar expansion tank so as to ensure complete ab-

sorption of the expansion of the fluid contained within the 

system, with reference to the prevailing regulations on the 

matter. In particular, consider fluid characteristics, consid-

erable fluctuation of service temperature and vapour that 

might be generated during solar collector stagnation stage. 

Proper size of expansion tank ensures setting off of all vol-

ume changes of the heat transfer fluid, avoiding excessive 

pressure increase. Limited pressure changes avoid reach-

ing safety valve opening pressure and the consequent fluid 

drainage.

General information

The following symbols are used in this manual:

 

9

CAUTION! =

  Identifies  actions  that  require  caution  and 

adequate preparation.

 

0

STOP! =

 Identifies actions that you MUST NOT do.

This manual, Code
- Rev.
comprises
pages.

GENERAL INFORMATION

General Safety Information . . . . . . . . . . . . . . . . . . . . . . 2

2 Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Description of the appliance . . . . . . . . . . . . . . . . . . . . . 3

Safety and control devices. . . . . . . . . . . . . . . . . . . . . . . 3

Identification  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

System layout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

INSTALLATION

Technical specifications. . . . . . . . . . . . . . . . . . . . . . . . . 5

Unpacking the product . . . . . . . . . . . . . . . . . . . . . . . . . 5

Installation premises  . . . . . . . . . . . . . . . . . . . . . . . . . . 5

10 Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

11 

Water connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

12 

Typical water system schematics . . . . . . . . . . . . . . . . . . 7

13 

Electric connections and wiring diagrams. . . . . . . . . . . 7

COMMISSIONING AND MAINTENANCE

14 

System flushing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

15 

System filling cock. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

16 

Device cleaning and maintenance  . . . . . . . . . . . . . . . .11

17 

Interventions on the hydraulic system  . . . . . . . . . . . . .11

18 

Recycling and disposal  . . . . . . . . . . . . . . . . . . . . . . . . .11

Summary of Contents for RSS MR

Page 1: ...cod 20124605 rev 2 10 2017 1 2 3 4 5 0 6 RSS MR MRS EN INSTALLATION AND MAINTENANCE MANUAL ...

Page 2: ...rformed by a qualified heating engineer 9 9This instruction manual is an integral part of the product It must be kept safe and must ALWAYS accompany the product even if it is sold to another owner or transferred to another user or to another installation If you lose this manual or der a replacement immediately Keep the product purchase documents to be presented to the R authorised Technical Assist...

Page 3: ...allows transferring sun power from collec tors to a storage system The solar station R is enclosed in an EPP Polypropylene foam insulating casing and is designed to perform system flushing system filling and emptying circulator removal The key components are high efficiency circulator with variable speed already hard wired shut off valves as non return valves thermometers pressure gauge fitting fo...

Page 4: ... temperature gauge 5 Insulation 6 Tap A for system filling draining 7 Pump 8 Pressure gauge 9 Tap B for system filling draining 10 Safety valve 6 bar 11 Fixing bracket 12 Solar controller 13 Display 14 Multidirectional joystick 15 Terminal strip M Solar circuit outlet Inlet of heat transfer fluid coming from solar collector R Solar circuit return Outlet of heat transfer fluid towards solar collect...

Page 5: ... resistance exchanger solar collectors and pipes at the maximum flow rate conditions provided Installation 8 UNPACKING THE PRODUCT Package content 1 2 5 6 3 8 7 4 1 Solar station 2 Bag containing 3 probes 1 5 m long only for version MRS 3 Solar controller only for version MRS 4 Terminal strip only for version MR In a plastic bag the following material is also supplied 5 Instruction manual 6 Instru...

Page 6: ...ransfer fluid towards solar storage system RB Storage system return 3 4 M Inlet of heat transfer fluid from solar storage system SV Safety valve drain VE Expansion tank fitting E Solar expansion tank not supplied T Safety valve outlet pipe not supplied Connect delivery fittings M and return fittings R found at the top of the solar station to the solar plant Connect delivery fittings MB and return ...

Page 7: ...is not responsible for any damage caused by failure to earth connect the device and failure to comply with what is indicated in the wiring diagrams Refer to the manual supplied with the solar controller for de tails of all electrical connections programming etc Version with solar regulator MRS CN4 CN3 M4 M3 M2 M1 3 2 1 4 5 6 CN6 F AE 230V 50Hz AN GD U1 U2 N L B A S6 S4 S5 S3 S2 S1 S1 S2 S3 C S4 AE...

Page 8: ...culator supplied with version MR needs a PWM signal con trol with the characteristics below REG MO 230 CONTROL PUMP AE 230V 50Hz C N GND PWM L PE L N PE AE Power supply connections to be made by the installer REG Generic solar regulator C Circulator with PWM control MO Terminal strip MO 230 CONTROL PUMP AE 230V 50Hz C N GND PWM L PE L N PE EVOSOL AE Power supply connections to be made by the insta...

Page 9: ... power Symbol Value PWM input frequency f 100 4000 Hz Consumption in stand by 1 W High voltage level of input signal UiH 4 24 V Low voltage level of input signal UiL 1 V Input signal current IiH 10 mA Input Duty cycle PWM 0 100 14 SYSTEM FLUSHING Before filling the system with mixture of water and glycol it is necessary to flush the pipes of the solar system to eliminate all residues of fluid or s...

Page 10: ...ture Mixture of glycol and water 1 2 3 4 5 0 6 B A VM VR PC PC Heat transfer fluid filling pump To fill the system proceed as follows Connect the filling pump PC as shown Turn handle on valve VR clockwise Open taps A and B on the return tube Open manual degassing tap and any bleeder valve lo cated at the highest points of the system and keep them open throughout the filling procedure Pump the heat...

Page 11: ... data sheet supplied with the glycol 17 2 Disassembling the circulator 9 9Remove the circulator when system has cooled down Before removing circulator C Cut power off to the solar station and to the connected integration system by setting the system s main switch and the device s main switch to OFF Disconnect circulator power by removing connectors D and E Move away any wiring and electric devices...

Page 12: ...llo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice ...

Reviews: