4
Model
Riello RDB2
Ignition
8 kV / 16 mA
Electrical supply
230/280 V
– 50 Hz fused at 5A
Control box
RBL 535 SE/LD analogue
Motor
RBL 90W
Pump
RBL
Rpm
2,700
Fuel
Kerosene C2
Capacitor
4.5 mF
Output
Input
Nozzle
Pump
pressure
Primary air
damper
Secondary
air damper
CO
2
15.0 kW·h
50,000 Btu·h
15.5 kW·h
52,860 Btu·h
0.45 x 60ºES
110 psi
7.6 bar
B
2.0
11.0%
17.5 kW·h
*
60,000 Btu·h
19.1 kW·h
64,993 Btu·h
0.5 x 80ºEH
130 psi
9 bar
B
4.0
11.3%
20.5 kW·h
70,000 Btu·h
22.1 kW·h
75,528 Btu·h
0.6 x 80ºEH
130 psi
9 bar
C
4.0
11.5%
20.5 kW·h
70,000 Btu·h
22.1 kW·h
75,528 Btu·h
0.6 x 80ºEH
130 psi
9 bar
C
3.0
11.5%
23.4 kW·h
*
80,000 Btu·h
25.0 kW·h
85,350 Btu·h
0.65 x 80ºEH
135 psi
9.3 bar
C
5.0
11.5%
26.3 kW·h
90,000 Btu·h
28.3 kW·h
96,374 Btu·h
0.75 x 80ºEH
135 psi
9.7 bar
D
5.5
11.5%
29.0 kW·h
100,000 Btu·h
31.5 kW·h
107,441 Btu·h
0.85 x 80ºEH
130 psi
9 bar
C
4.5
12.0%
32.8 kW·h
*
112,000 Btu·h
35.3 kW·h
120,500 Btu·h
1.0 x 80ºEH
110 psi
7.6 bar
E
4.0
12.0%
36.0 kW·h
125,000 Btu·h
39.2 kW·h
133,712 Btu·h
1.1 x 80ºEH
125 psi
9 bar
E
4.5
12.0%
Note 1
The primary air damper should remain at the position indicated. The secondary air damper settings are
for guidance only; individual site conditions
—such as the type of flue and level of draught—will often compel
deviation from the recommended positions. See
fig 3
for air damper adjustment instructions.
Note 2
The CO
2
ratio is correct for a combustion air temperature of 20°C; see
fig 2
for other temperatures.
Note 3
The
*
indicates factory settings. To attain different outputs, changes to the nozzle specification, pump
pressure and air setting may be required. The boiler should be set to match the heat requirements of the
system. Incorrect matching may impede the boiler's correct operation and invalidate its warranty.
BURNER SETUP
Fig 1
TECHNICAL SPECIFICATIONS