27
20170392
GB
Start-up, calibration and operation of the burner
7.1
Notes on safety for the first start-up
7.2
Adjustments prior to ignition
The optimum calibration of the burner requires an analysis of the
flue gases at the boiler outlet and interventions on the following
points.
7.2.1
Nozzle
See information on page 19.
7.2.2
Pump pressure
The pump leaves the factory set at 25 bar. It is activated by
loosening the vacuometer connection plug. See information on
page 24.
7.3
Maximum fuel flow rate adjustment
It is carried out by choosing the right nozzle in Tab. K:
Tab. K
NOTE:
25 bar for fluid oil - up to 30 bar for thick oil (viscosity
20°E
at 50°C).
If you want a maximum flow rate somewhere between the two
values shown in the table, select a nozzle with a higher flow rate.
Flow rate can be decreased at a later time by acting on the
pressure variator, as specified in
7
Start-up, calibration and operation of the burner
ATTENTION
The first start-up of the burner must be carried out
by qualified personnel, as indicated in this manual
and in compliance with the standards and
regulations of the laws in force.
ATTENTION
Check the correct working of the adjustment,
command and safety devices.
Model
Nozzle
BERGONZO
B5
Output
Maximum flow
rate
kg/h
Fuel pressure
at pressure gauge delivery
bar
Fuel maximum pressure at
pressure gauge return
bar
14
0
150
150
25
24.5
125
125
25
24.8
100
100
25
24
90
90
25
21
80
80
25
22.5
200
200
200
25
24
175
175
25
24.5
150
150
25
24.5
125
125
25
24.8
100
100
25
24
300
300
300
25
24
275
275
25
23.5
250
250
25
25
225
225
25
24
200
200
25
24
175
175
25
24.5
150
150
25
24.5
450
450
450
25
22.5
400
400
25
23.5
350
350
25
23.5
325
325
25
24
300
300
25
24
275
275
25
23.5
250
250
25
25
225
225
25
24
ATTENTION
To prevent clogging, remove the filter from the
nozzle.
Summary of Contents for PRESS 140 P/N
Page 2: ...Translation of the original instructions...
Page 57: ...55 20170392 GB Appendix Electrical panel layout 0 1 2 2 2 0 DIRECT START UP...
Page 58: ...20170392 56 GB Appendix Electrical panel layout 0 1 1 1 STAR TRIANGLE START UP...
Page 59: ...57 20170392 GB Appendix Electrical panel layout 0 1 0...