SOLAR CONTROLLER
The first time you switch on the boiler, you will need to
set time and day. To do so, proceed as follows.
− Turn the function selector (3) to " "
− Turn the parameter selector (4) until the "Clock"
menu appears.
− Press the confirm key (2).
− Turn the parameter selector (4) to set the desired
time .
− Press the confirm key (2) to confirm.
− Repeat the above steps to set the date .
−
Turn the function selector (3) to "
"
9
You can exit programming mode at any time sim-
ply by turning the function selector (3). If you exit
programming mode in this way, any changes made
but not confirmed (by pressing the confirm key) will
be lost .
STARTING UP THE BOILER
If a timer or room thermostat is installed, these must
be switched on and adjusted to a temperature higher
than current room temperature before the boiler can
start up.
The boiler will remain in stand-by mode until the bur-
ner ignites following a request for heat. The green LED
(3) on the left of the control panel lights to show that a
flame is being detected.
The boiler will carry on functioning until the set tem-
peratures are reached, when it will return to stand-by
mode while continuing to display the central heating
flow temperature.
If any ignition or functioning errors occur, the boiler
performs a “SAFETY SHUTDOWN”. The green LED on the
control panel goes out and an error code flashes on the
display. The red LED (5) indicates a burner lock-out. See
the “WARNING LEDS AND ERRORS” section for details on
the various error codes and how to reset the boiler.