TECHNICAL ASSISTANCE SERVICE

TECHNICAL ASSISTANCE SERVICE

15 

TEMPORARY SHUTDOWN

If you are going away for a short period of time like a weekend 

or a short holiday, etc., and outdoor temperatures are going to 

remain above ZERO, proceed as follows.

 

− Adjust the combination storage cylinder’s thermostat to 

its minimum setting.

 

9

If outdoor temperature may drop below ZERO (risk of freez-

ing) perform the operations described in the “Preparing for 

extended periods of disuse” section.

16 

PREPARING FOR EXTENDED PERIODS OF DISUSE

If the combination storage cylinder is not going to be used for an 

extended period of time, prepare it for shut-down as follows:

 

− Switch the electricity supply to the storage cylinder and to 

any associated boiler OFF at the main switch and at the 

control panel (if present)

 

− Close the shut-off cocks for the domestic hot water cir-

cuit.

 

9

Drain the central heating circuit and domestic hot water cir-

cuit if there is any risk of freezing.

16.1 

Maintenance

Scheduled  maintenance  is  essential  for  the  safety,  efficien-

cy and long working life of your combination storage cylinder. 

Proper maintenance also reduces energy consumption and en-

sures reliability over time. Have your combination storage cylin-

der serviced either by the manufacturer’s Technical Assistance 

Service or by a qualified heating engineer at least once a year.

Perform the following operations before beginning any main-

tenance:

 

− Switch the electricity supply to the storage cylinder’s 

valve group and to any associated boiler OFF at the main 

switch and at the control panel (if present)

 

− Close the shut-off cocks for the domestic hot water circuit

 

− Empty the combination storage cylinder.

17 

CLEAN THE COMBINATION STORAGE CYLINDER

EXTERNAL CLEANING

Clean the outside of the combination storage cylinder’s insula-

tion with a soft cloth damped in soapy water. To remove stub-

born marks, use a cloth damped in a 50% mix of water and 

denatured alcohol or a suitable cleaning product. Dry the com-

bination storage cylinder after cleaning it.

 

0

Do not use abrasive products, petrol or triethylene.

18 

RECYCLING AND DISPOSAL

The device is primarily composed of:

Material

Component

steel

structural work

PU (polyurethane)

insulation (models 430 - 550)

polystyrene - polyester felt

insulation (models 750 - 1000)

PE (polyethylene)

water connection washers

ABS (acrylonitrile-butadiene-

styrene)

lining and covers

At the end of the device's useful life, these components must be 

separated and disposed of according to current regulations in 

the country of installation.

Summary of Contents for KOMBISOLAR 1000 3S

Page 1: ...cod 20145435 rev 2 07 2018 KOMBISOLAR 3S EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Page 2: ...omfort in the home for many years to come Arrange for your R Combi nation cylinder to be serviced regularly by an authorised R service centre Their personnel are specially trained to keep your Combina...

Page 3: ...System layout 6 6 Technical specifications 8 7 Typical water system schematics 13 8 Location of sensors 15 9 Overall dimensions and water fittings 16 INSTALLER 10 Unpacking the product 18 11 Handling...

Page 4: ...t immediately Keep the product purchase documents to be presented to the R authorised Technical Assistance Service to request a service call under warranty 9 9Size the solar expansion tank so as to en...

Page 5: ...mwasserbetrieb Electrical consumption Stromaufnahme Maximum working pressure of inertial storage cylinder Max Druck Pufferspeicher Betrieb Maximum working temperature of inertial storage cylinder Max...

Page 6: ...torage cylinder temperature gauge 10 Domestic hot water outlet 11 DHW coil 12 Vent valve fitting 13 Outlet from boiler 14 Flow from second boiler 15 Heating system inlet 16 Return to second boiler 17...

Page 7: ...linder temperature gauge 10 Domestic hot water outlet 11 DHW coil 12 Vent valve fitting 13 Outlet from boiler 14 Flow from second boiler 15 Heating system inlet 16 Return to second boiler 17 Flow from...

Page 8: ...12 8 17 4 19 8 l DHW coil water capacity 23 6 23 6 30 4 30 4 l Top primary coil heat exchange surface 1 17 1 31 1 72 1 72 m2 Bottom primary coil heat exchange surface area 1 80 2 10 2 90 3 34 m2 DHW...

Page 9: ...of 3000 l h With T 35 C and primary temperature 80 C Performance achieved with boiler of suitable power configured for a flow rate of 1500 l h CONFIGURATION B KOMBISOLAR 3S Boiler Description KOMBISO...

Page 10: ...ary temperature 80 C Performance achieved with boiler of suitable power configured for a flow rate of 3000 l h CONFIGURATION D KOMBISOLAR 3S Boiler Description KOMBISOLAR 3S 430 550 750 1000 Domestic...

Page 11: ...E DROP mbar 600 700 800 900 500 400 300 200 100 0 0 1000 2000 3000 4000 5000 6000 430 550 750 1000 FLOW RATE l h Pressure drops KOMBISOLAR 3S BOTTOM COIL PRESSURE DROP mbar 600 700 800 900 500 400 300...

Page 12: ...12 GENERAL GENERAL Pressure drops KOMBISOLAR 3S DHW COIL PRESSURE DROP mbar 600 700 500 400 300 200 100 0 0 1000 2000 3000 4000 5000 550 750 1000 430 FLOW RATE l h...

Page 13: ...n troller 19 KOMBISOLAR 3S 430 550 20 Solar circuit expansion vessel 21 DHW user 22 Isolating valve 23 Thermostatic mixer valve 24 Safety valve 25 Bleed valve 26 DHW circuit expansion vessel 27 Filter...

Page 14: ...ISOLAR 3S 750 1000 20 Solar circuit expansion vessel 21 DHW user 22 Isolating valve 23 Thermostatic mixer valve 24 Safety valve 25 Bleed valve 26 DHW circuit expansion vessel 27 Filter 28 System cocks...

Page 15: ...nti freeze must be fitted with water dis connectors 8 LOCATION OF SENSORS R KOMBISOLAR 3S combination storage cylinders incorporate sockets for solar controller and boiler sensors Make sure that these...

Page 16: ...ler 1 1 4 F RA50 Return to boiler water 50 C 1 F CB Buffer tank charging 1 F RI SB Heating system return Inertial storage cylinder drain 1 1 4 F VS Vent valve fitting 1 F DESCRIPTION KOMBISOLAR 3S 430...

Page 17: ...Return to boiler water 50 C 1 F CB Buffer tank charging 1 F RI SB Heating system return Inertial storage cylinder drain 1 1 4 M VS Vent valve fitting 1 F DESCRIPTION KOMBISOLAR 3S 750 1000 A 365 365...

Page 18: ...he combination cylinder from the pallet To lift the combination cylinder remove the plug 2 and screw an eyebolt 1 of suitable capacity for the weight into the hole 3 1 2 3 1 1 If suitable equipment is...

Page 19: ...dren since it can become a potential hazard Dispose of packaging material in com pliance with applicable legislation 13 PLACE OF INSTALLATION R KOMBISOLAR 3S combination storage cylinders can be in st...

Page 20: ...The domestic hot water tank must be filled and pressur ised before the inertial storage cylinder is filled Solar heating circuit Once the system has been started up perform the following checks Check...

Page 21: ...reliability over time Have your combination storage cylin der serviced either by the manufacturer s Technical Assistance Service or by a qualified heating engineer at least once a year Perform the fol...

Page 22: ...emperature setting There is air in the primary circuit Bleed the circuit SOLAR COLLECTOR CIRCUIT FAULT CAUSE SOLUTION The buffer tank functions incorrectly or irregularly There is air in the circuit B...

Page 23: ...environment and save energy before leaving for the weekend or a short break etc provided outdoor temperatures will remain above ZERO simply adjust the combi nation storage cylinder s temperature cont...

Page 24: ...lo 7 37045 Legnago VR www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liabl...

Reviews: