25
INSTALLATION
GITRÈ 5
-
GITRÈ 6
LV
FU
1
2
3
4
5
6
7
8
9
10
11
12
CO1
LR
2
1
C
TR
C
3
A 1
B 2
COM.G.
CO1A
L1 N PE TA TA LPI NPI PE
PI
2
1
C
TS
2
1
C
Tm
MO1
L N PE
AE
230V ~ 50Hz
RE
DAI
C
C
NC
1
2
N
N
NC
3
2
1
N
L1
X6
TB
XP6
C
MV
P
M
V
F
E
White
Yellow/Green
Black Red
BURNER CONTROLLER
HEAT
REQUEST
Black
White
Blue
Grey
Violet
AE
Power supply
COM.G.
3 position function selector
LV
Mains power indicator
LR
Burner lockout indicator
TS
Safety thermostat (110°C 0/-6) (*)
TR
Boiler control thermostat (55 -
82°C) (*)
Tm
Minimum temperature
thermostat (50°C) (*)
FU
Mains power fuse 6.3 A-T
CO1-CO1A Multi-connectors
MO1
Terminal strip
PI
Central heating pump (not
supplied)
DAI
Automatic shut-off device (not
supplied; only where required).
The automatic shut-off device
(DAI) and the relay (RE) must
be suitable for a 230 VAC power
supply.
RE
Relay (not supplied)
X6
6 pin burner connector (female)
(*) Homologated
C Condenser
E
Ignition electrodes
F
Flame detector
MV
Fan motor
P
Short circuit socket
TB
Burner ground
V
Fuel oil valve
XP6
6 pin burner connector (male)