Summary of Contents for G3BF 490T53

Page 1: ...2902136 6 Installation use and maintenance instructions Kerosene burners One stage operation CODE MODEL TYPE 3749053 G3BF 490T53 3749257 G5BF 492T57 3748953 G5BF 489T53...

Page 2: ......

Page 3: ...rner with CE marking in conformity with EEC directives EMC89 336 EEC Low Voltage 73 23 EEC Machines 89 392 EEC and Efficiency 92 42 EEC The intake air temperature must not be over 70 C The burner meet...

Page 4: ...ange Nuts for flange TYPE A B C D E F G H I 490 T53 271 249 288 193 90 93 207 75 21 492 T57 271 249 288 191 90 93 226 75 26 489 T53 271 249 288 191 89 79 237 75 37 Flange Burner C F G 130 I 4 5 E A 11...

Page 5: ...power kW D5426 25 30 35 0 2 0 6 0 6 0 0 2 0 4 Pressure in the combustion chamber mbar 1 5 2 2 5 Fuel output kg h 20 25 30 Thermal power kW D5425 0 8 0 0 4 Pressure in the combustion chamber mbar 2 3 4...

Page 6: ...indispensable This solution however is less safe than previous one due to the possibility of leakage of the valve PRIMING THE PUMP Start the burner and wait for the priming Should lock out occur prio...

Page 7: ...owards the arrow The photoresistance is fitted directly into the control box underneath the ignition transformer on a plug in support TESTING Check the shut down of the burner by opening the thermosta...

Page 8: ...ed of excess air etc All these conditions may require a different air damper setting NOZZLES RECOMMENDED Monarch type R NS Delavan type W A E B Steinen type Q H Danfoss type B H S Angle 60 in most cas...

Page 9: ...TO THE RIGHT sign In order to increase the volume of air entering the combustion chamber and thus diminishing its pres sure There is a reduction of CO2 and the adhesion of the flame to the air diffus...

Page 10: ...below ELECTRODE SETTING BURNER START UP CYCLE 3 1 2 3 D5141 Turn to the right sign to increase the air quantity in the combustion chamber turn to the left sign to decrease it S7021 Attention Before as...

Page 11: ......

Page 12: ......