30
ENGLIS
H
Fig. 1
Fig. 2
To form the electrical connections for the
BAG
3
MIX FAMILY
COND
, access must be obtained to the
BAG
3
MIX FAMILY
COND
and the boiler card.
To gain access to the BAG
3
MIX FAMILY COND:
- Remove the front cover panel from the BAG
3
MIX FAMILY
COND.
In the appliance you find connected:
- white cable for main supply
- black cable with 5 poles collector
- black bipolar cable with probs
In the envelopes you find:
- flat cable
- faston jumper
- probe wiring and thermostats
- PCB supply cable - 4 poles
If you decide to use cables other than those supplied, ca-
bles with a 0,50 mm
2
section must be used. The length of
these connections must not exceed 15 metres.
CONNECTING THE ELECTRONIC SYSTEM CONTROL BOARD (sup-
plied) TO THE BOILER’S ELECTRONIC BOARD
To form the connection, proceed as follows:
1. Remove the boiler’s cover, open the back cover on the
control panel, as shown in the manual for the boiler.
2. Insert the BE08 board supplied (C) into its seating inside
the control panel, as shown in figure 2.
3. Connect the flat cable to the electronic system control
board and the electronic boiler control board (see photo
1 and the wiring diagram).
4.
To provide power to the electronic system
control board, connect the cable’s four-pole connector
(supplied), as shown in photo 2
Connect the prods to the mains power supply as shown
in fig. 3
Blue wire - neutral
Brown wire - phase
(see the wiring diagram)
Boilers from inside
C
Boilers from outside
C
C
photo 1
inside boiler
outside boiler
photo 2
outside boiler
inside boiler
outside boiler
outside boiler
2.6
Electric connections