19
ENd USER
1
Time of day
0…23.59
h/min
---
Setpoints
5 (*) Line 5 will be hidden when using an additional room unit:
Reduced room temperature setpoint
10…30
°C
20
Reduced boiler temperature setpoint
30...boiler temperature setpoint
Time program HC 1
11
Switch-on time 1st phase
00:00…24:00
hh:mm
06:00
12
Switch-off time 1st phase
00:00…24:00
hh:mm
22:00
13
Switch-on time 2nd phase
00:00…24:00
hh:mm
24:00
14
Switch-off time 2nd phase
00:00…24:00
hh:mm
24:00
15
Switch-on time 3rd phase
00:00…24:00
hh:mm
24:00
16
Switch-off time 3rd phase
00:00…24:00
hh:mm
24:00
Time program DHW
31
Time program DHW, 1st phase on
00:00…24:00
hh:mm
06:00
32
Time program DHW, 1st phase off
00:00…24:00
hh:mm
22:00
33
Time program DHW, 2nd phase on
00:00…24:00
hh:mm
24:00
34
Time program DHW, 2nd phase off
00:00…24:00
hh:mm
24:00
35
Time program DHW, 3rd phase on
00:00…24:00
hh:mm
24:00
36 Time program DHW, 3rd phase off
00:00…24:00
hh:mm
24:00
45
Standard time programs for HC and DHW
No/Yes
---
No
(press simultaneously buttons
-
and
+
for 3 seconds)
516 Summer / winter changeover temperature
8…30
°C
20
(30=changeover deactivated)
520 THIS PARAMETER IS NOT USED IN THIS BOILER
10
dON'T CHANGE THE SETTINGS
629 Enduser can acknowledge a pending maintenance alarm via this
parameter
(0/1=disattivato/attivato
0
726 Maintenance code contains enumeration value of
0…255
0
maintenance alarm (exact cause)
(*)
External probe connected: setting low temperature setpoint
External unrelated probe: setting low setpoint of the boiler.
CONTROL PANEL: CONTROL OF BOILER, DIRECT CH ZONE AND DHW PRODUCTION
6
COMPLETE LIST OF PARAMETERS
LIST OF END USER LEVEL PARAMETERS
N° Description
Range
U/M Default