Riello AARIA ONE INVERTER 25 Installation And Technical Service Instructions Download Page 18

INSTAllATION

18

L Phase
N Neutral
IG 

System main switch

CP 

Presence contact

GR Grey
bR brown
YG 

Yellow / green

bL blue

GR

GR

C P

L

N

I G

GR

BL

YG

BR

 

connect the new power cord

For the sizing of the electrical power cables, use the following 
table:

Model

25

Electrical characteristics

Power supply

230/1/50

V/Ph/Hz

Power cable

Double insulation

Type

Power cable

3 x 1,5

n. x mm²

The cable sections specified in the table are minimum re-
quirements. The correct size must be calculated taking in-
to account the actual length, the type of routing and other 
conditions set by the existing regulations.

 

fasten the wires with the wire retainer

 

complete the electric connections and refit all components 
by performing the described operations in reverse order

Check that:

 

the characteristics of the power network are suitable for 
the device usage values

 

the power supply voltage corresponds to the nominal val-
ue +/- 10%

 

all of the power network disconnect devices must be 
equipped with contact openings (3 mm) in order to allow 
for complete disconnection, in accordance with the con-
ditions required

Mandatory items:

 

have an omnipolar magneto-thermal circuit breaker and 
a padlockable disconnecting switch compliant with the 
IEC-EN Standards (contact opening of at least 3 mm), with 
adequate breaking power and differential protection, in-
stalled near the equipment

 

connect the device to a properly functioning earthing sys-
tem

 

for any electrical intervention, always refer to the wiring 
diagrams contained within this booklet

 

take anti-static precautions in case of weather conditions 
where humidity is less than 40%

Electric connections shall be made in compliance with na-
tional regulations.

Avoid placing the connection cables less than 1 metre away 
from radio and video systems.

 

0

It is forbidden to earth the device together with pipes, 
lightning conductors or the earthing system of a telephone 
line. Using an improper earthing system can cause electric 
shocks.

 

0

It is forbidden to connect other devices in parallel to the 
unit.

Presence contact

Through this contact it is possible to connect an external de-
vice that inhibits operation of the unit such as: window open-
ing contact, remote on/off, infrared presence sensor, activation 
badge etc. In case of power failure, the unit will restart with the 
same settings if during the first 7 seconds after power supply is 
restored no action is performed.

CP 

Presence contact

GR Grey
bR brown
YG 

Yellow / green

bL blue

GR

GR

C P

GR

BL

YG

BR

To connect the contact:

 

remove the jumper on the contact

 

connect to a dry contact

• 

Logic:

 

contact open: OFF, the control panel displays the symbol 

CP

 

contact closed: ON

Use a double insulated cable.

It is prohibited to connect in series the 

CP

 contact of multiple 

devices on the same dry contact.

2.13

  Mounting the low-wall unit

After performing the connections:

Summary of Contents for AARIA ONE INVERTER 25

Page 1: ...AARIA ONE INVERTER 02 2017 cod Doc 0083695 rev 0 EN INSTALLATION AND TECHNICAL SERVICE INSTRUCTIONS...

Page 2: ...n We would like to congratulate you on having recommended a R unit a modern product that is capable of ensuring maximum comfort at length with a high degree of reliability efficiency quality and safet...

Page 3: ...s or systems in need of upgrading p 12 2 9 Positioning p 13 2 10 Condensate discharge connection p 15 2 11 Wiring diagram p 16 2 12 Electrical connection p 17 2 13 Mounting the low wall unit p 18 Moun...

Page 4: ...its contain refrigerant gas operate carefully so as to avoid damaging the gas circuit and the fin bank 9 Any gas leaks indoors can generate toxic gases if they come into contact with naked flames or h...

Page 5: ...t when the temperature is greater than 7 C temperature probe of the lower heat exchanger transmits the detected value to the main electronic board which activates cooling mode if the detected temperat...

Page 6: ...8 Condensation discharge 9 Anti lifting bracket 10 Remote control 11 Terminal blocks 12 Air filter 13 Room air probe 14 Upper exchanger 15 Lower Fan 16 Condensation pump 17 Lower exchanger 18 Maximum...

Page 7: ...ty 1 00 l h Upper Fan Fan Tangential Type Speed 3 n Maximum air flow 380 m h Medium air flow 310 m h Minimum air flow 260 m h Maximum speed 1500 rpm Medium speed 1250 rpm Minimum speed 900 rpm Lower F...

Page 8: ...V Ph Hz Protection factor X0 IP Cooling performance A35 A27 1 Power consumption at maximum air flow 2 90 A Current consumption at maximum power 4 40 A Power consumption at average air flow 2 46 A Powe...

Page 9: ...ty side fluid is the air inside the rooms During the wintertime the heat pump extracts the thermal en ergy from the outdoor air and delivers it to the room air thereby heating it During the summertime...

Page 10: ...er instruction booklet in French user instruction booklet in Spanish Warranty Spare parts labels energy label warranty terms for Italy It is also supplied as kit remote control CR2025 3V battery no 2...

Page 11: ...lower closing panel 1 Polystyrene elements 2 Metal support 3 Paper template and plastic sheets for ducts 1 2 3 remove the metal support remove the polystyrene elements remove the paper template remove...

Page 12: ...t will cause the expelled air to recirculate locations with aggressive or explosive atmospheres or with inflammable fluids direct exposure to sunlight and proximity to heat sources humid locations or...

Page 13: ...pter Recommended distances p 12 mark the positions of the holes for the ducts use a drill drill a pilot hole use a core drill drill the through hole into the wall keep a downward inclination toward th...

Page 14: ...paints suit able for plastic surfaces to avoid problems with the move ment of the flaps 9 Do not use thick sticky paints like enamels Fixing the metallic support to the wall The devices are provided...

Page 15: ...ter leaks 9 The drainage pipe must be insulated for sections running inside houses in order to prevent condensate formation on its surface 9 If needed it is possible to empty the condensation collecti...

Page 16: ...ature probe NTC 5 28 k at 25 C OT Outdoor temperature probe NTC 5 28 k at 25 C OPT Lower exchanger temperature probe NTC 5 28 k at 25 C GA Maximum level float N C contact GL Level float N A contact CP...

Page 17: ...ration must be done only by R Technical Service or qualified personnel ON OFF set the system main switch to OFF 9 Wait 10 minutes before touching the device electric compo nents To access the terminal...

Page 18: ...in stalled near the equipment connect the device to a properly functioning earthing sys tem for any electrical intervention always refer to the wiring diagrams contained within this booklet take anti...

Page 19: ...installed in the case of high wall installation To install lift the decorative side panels remove them by pulling horizontally 1 Plastic terminal board cover 2 Fixing screws 3 Front panel 4 Decorativ...

Page 20: ...unc tions and the screen also displays the active mode of operation the temperature and any alarms 1 Control panel 1 Keys and symbols 1 Value of the temperature desired 2 Setting value of some functio...

Page 21: ...ed minimum medium maximum or automatic 2 Enables Maximum power function Inserting the battery The remote control is powered with a dry lithium battery CR2025 3 0 V housed on a support inserted into a...

Page 22: ...ues are correct the earthing has been carried out correctly Configuring the installation The unit can be installed either on the lower part of the wall and on the upper part To optimise the distributi...

Page 23: ...lashes air flows upwards press The symbol uP appears air flows downwards Not performing other operations for 3 seconds the setting is saved Setting cooling only or heating only mode The device is fact...

Page 24: ...es deactivate the unit using only the on board control panel or remote control 3 4 Stop for an extended period of time If the device has not been used for an extended period of time carry out the foll...

Page 25: ...upply voltage electric connection tightening hydraulic joint status condensate tray cleaning electric absorption operation of the condensation drain 3 6 Extraordinary maintenance Safety drain If neede...

Page 26: ...r problem resolution E3 Outdoor air temperature probe fault E4 Lower exchanger probe fault Cooling Dehumidifying and Heating modes remain active Defrosting operates at fixed time cycles E5 Upper fan m...

Page 27: ...d disposal 27 4 DISPOSAL Packaging materials shall be disposed of separately so as to re cover and recycle them At the end of its service life the device shall be disposed of according to the existing...

Page 28: ...39 0442 630111 fax 39 0442 630371 www riello it As the manufacturer is constantly improving its products the aesthetic or dimensional features the technical data the equipment and accessories indicat...

Reviews: