background image

6

GENERAL

GENERAL

TECHNICAL SPECIFICATIONS

DESCRIPTION

7200 V Plus

200

300

430

550

800

1000

Type of storage cylinder

Vitrified

Storage cylinder layout

Vertical

Heat exchanger layout

Vertical

Storage cylinder capacity

206

298

432

545

716

875

l

Diameter of storage cylinder with insulation

605

755

1000

mm

Diameter of storage cylinder without insulation

500

650

790

mm

Height with insulation

1330

1840

1630

1980

1870

2195

mm

Insulation thickness

50

100

mm

Diameter/length of first magnesium anode

33/450

33/520

33/450

mm

Diameter/length of second magnesium anode

-

33/450

mm

Flange diameter

118

mm

Diameter/length of sensor sockets

16/175

7/210

Ø mm

Sleeve for electric heating element (not supplied)

1 1/2” F

Ø

Maximum power absorbed
    Primary coil at 80°C

50,2

80,7

92,6

92,6

93,8

114

kW

    Primary coil at 88°C

60,7

96,9

117

117

113

134

kW

Coil water capacity

9,2

12,2

25,5

25,5

26,3

30,6

l

Coil heat exchange surface area

1,45

1,93

2,95

2,95

3,05

3,53

m

2

Domestic hot water production (

T 35°C)

    Primary coil at 80°C

1200

1954

2281

2281

2319

2816

l/h

    Primary coil at 88°C

1465

2355

2910

2910

2830

3341

l/h

Maximum working pressure of coils

10

bar

Maximum working pressure of storage cylinder

10

7

bar

Maximum operating temperature

99

°C

Net weight with insulation

82

110

155

170

200

240

kg

Heat loss according to EN 12897:2006 at 

T=45 °C

74

69

60

68

156

175

W

Energy efficiency class

C

B

D

Pressure drops

COIL

Pressure drop (mbar)

500

400

300

200

100

0

0

1000

2000

3000

4000

5000

Mod. 1000

Mod. 800

Mod. 200

Mod. 430-550

Mod. 300

Flow rate (l/h)

Summary of Contents for 7200.1000 V PLUS

Page 1: ...cod 08700190 rev 7 12 2016 7200 V Plus EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Page 2: ...authorised R service centre Their personnel are specially trained to keep your storage cylinder efficient and cheap to run R service centres also stock any original spare parts that might be required...

Page 3: ...specifications 6 7 Water circuit 7 8 Location of sensors 8 9 Overall dimensions and water fittings 9 INSTALLER 10 Unpacking the product 11 11 Handling 11 12 Place of installation 13 13 Installation i...

Page 4: ...he boiler connected to the storage cylinder as instructed in its own manual Switch the storage cylinder OFF at the control panel if fitted and at the mains power switch Drain the central heating circu...

Page 5: ...ell Serial number Seriennummer Code Year of manufacture Baujahr Maximum absorbed power T Primary 80 C Max Leistungsaufnahme T Prim rkreis 80 C Operating pressure Betriebsdruck Power supply Stromversor...

Page 6: ...ctric heating element not supplied 1 1 2 F Maximum power absorbed Primary coil at 80 C 50 2 80 7 92 6 92 6 93 8 114 kW Primary coil at 88 C 60 7 96 9 117 117 113 134 kW Coil water capacity 9 2 12 2 25...

Page 7: ...e installed as standard in the vertical position to fitting 11 an expansion vessel safety system can be connected directly to the top flange Note The above schematic is purely indicative 9 9R 7200 V P...

Page 8: ...nstallers must use their expertise to ensure proper installation and functioning in compliance with all applicable legislation Ps Bt Ps M Ps Socket for storage cylinder THERMOSTAT SENSOR or storage cy...

Page 9: ...430 550 UAC Domestic hot water outlet 1 F ES Heat exchanger inlet 1 F 1 1 4F RC DHW recirculation 3 4 F US Heat exchanger outlet 1 F 1 1 4F EAF SB Domestic cold water inlet storage cylinder drain 1 F...

Page 10: ...inlet 1 1 4F RC DHW recirculation 1 M US Heat exchanger outlet 1 1 4F EAF SB Domestic cold water inlet storage cylinder drain 1 1 4M RE Sleeve for electric heating element not supplied 1 1 2F A 1470...

Page 11: ...certificate and barcode label Spare parts catalogue Hydraulic test certificate 4 adjustable feet 9 9The second anode for installation instead of the inspection flange is supplied separately and must...

Page 12: ...since it can become a potential hazard Dispose of packaging material in compliance with applicable legislation MODELS 7200 V Plus 800 to 1000 Make sure that any lifting equipment is of adequate capaci...

Page 13: ...V Plus storage cylinders can be installed in any room where there is no specific requirement for an electrical protection rating higher than IP X0D 0 4 m 0 6 m 0 3 m 0 4 m 9 9Respect the minimum speci...

Page 14: ...its have been bled Turn the main power switch OFF and make sure that the water heating system shuts down completely Provided the above checks have been completed satisfactorily restart the system and...

Page 15: ...cleaning product Dry the storage cylinder after cleaning it 0 0Do not use abrasive products petrol or triethylene INTERNAL CLEANING MODELS 7200 V Plus 200 to 550 Removing and checking the magnesium a...

Page 16: ...suitable wrench to unscrew the anode holder 6 Check the magnesium anode for wear and replace it if necessary On completion of cleaning follow the above steps in the reverse order to refit all removed...

Page 17: ...licable legislation 20 TROUBLESHOOTING FAULT CAUSE SOLUTION The storage cylinder functions incorrectly or irregularly Flow rate too high Fit a pressure limiter Fit a flow reducer There are blockages o...

Page 18: ...will remain above ZERO simply adjust the storage cylinder s thermostat to its minimum temperature 9 9If outdoor temperature may drop below ZERO risk of freezing performtheoperationsdescribedinthe Prep...

Page 19: ...19 END USER END USER...

Page 20: ...el 0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore...

Reviews: