background image

18

END USER

END USER

END USER INSTRUCTIONS

Refer to the GENERAL SAFETY INFORMATION and PRECAUTIONS section for safety-related information.

21 

START-UP

The storage cylinder must be put into service for the first time by 

personnel from the manufacturer’s Technical Assistance Service.

Under certain circumstances, such as after long periods of 

disuse, the user may need to re-start it without involving the 

Technical Assistance Service. Before doing so, perform the 

following checks and operations.

 

− Check that the supply cocks in the domestic water circuit 

are all open

 

− Switch the electricity supply ON at the mains power 

switch and at control panel switch (if fitted).

22 

TEMPORARY SHUTDOWN

To reduce impact on the environment and save energy, before 

leaving for the weekend or a short break, etc., provided outdoor 

temperatures will remain above ZERO, simply adjust the storage 

cylinder’s thermostat to its minimum temperature.

 

9

If outdoor temperature may drop below ZERO (risk of 

freezing) perform the operations described in the “Preparing 

for extended periods of disuse” section.

23 

PREPARING FOR EXTENDED PERIODS OF DISUSE

If the storage cylinder is not going to be used for an extended 

period of time, perform the following operations:

 

− Switch the electricity supply to the storage cylinder’s 

valve group and to any associated boiler OFF at the main 

switch and at the control panel

 

− Close the shut-off cocks for the domestic hot water circuit.

 

9

Drain the central heating circuit and domestic hot water 

circuit if there is any risk of freezing.

24 

EXTERNAL MAINTENANCE

Clean the cover, painted and plastic parts with a cloth damped 

in soap and water. To remove stubborn marks, use a cloth 

damped in a 50% mix of water and denatured alcohol or a 

suitable cleaning product.

 

9

Do not use fuels, sponges impregnated with abrasive 

solutions or powder detergents.

End user

Summary of Contents for 7200.1000 V PLUS

Page 1: ...cod 08700190 rev 7 12 2016 7200 V Plus EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Page 2: ...authorised R service centre Their personnel are specially trained to keep your storage cylinder efficient and cheap to run R service centres also stock any original spare parts that might be required...

Page 3: ...specifications 6 7 Water circuit 7 8 Location of sensors 8 9 Overall dimensions and water fittings 9 INSTALLER 10 Unpacking the product 11 11 Handling 11 12 Place of installation 13 13 Installation i...

Page 4: ...he boiler connected to the storage cylinder as instructed in its own manual Switch the storage cylinder OFF at the control panel if fitted and at the mains power switch Drain the central heating circu...

Page 5: ...ell Serial number Seriennummer Code Year of manufacture Baujahr Maximum absorbed power T Primary 80 C Max Leistungsaufnahme T Prim rkreis 80 C Operating pressure Betriebsdruck Power supply Stromversor...

Page 6: ...ctric heating element not supplied 1 1 2 F Maximum power absorbed Primary coil at 80 C 50 2 80 7 92 6 92 6 93 8 114 kW Primary coil at 88 C 60 7 96 9 117 117 113 134 kW Coil water capacity 9 2 12 2 25...

Page 7: ...e installed as standard in the vertical position to fitting 11 an expansion vessel safety system can be connected directly to the top flange Note The above schematic is purely indicative 9 9R 7200 V P...

Page 8: ...nstallers must use their expertise to ensure proper installation and functioning in compliance with all applicable legislation Ps Bt Ps M Ps Socket for storage cylinder THERMOSTAT SENSOR or storage cy...

Page 9: ...430 550 UAC Domestic hot water outlet 1 F ES Heat exchanger inlet 1 F 1 1 4F RC DHW recirculation 3 4 F US Heat exchanger outlet 1 F 1 1 4F EAF SB Domestic cold water inlet storage cylinder drain 1 F...

Page 10: ...inlet 1 1 4F RC DHW recirculation 1 M US Heat exchanger outlet 1 1 4F EAF SB Domestic cold water inlet storage cylinder drain 1 1 4M RE Sleeve for electric heating element not supplied 1 1 2F A 1470...

Page 11: ...certificate and barcode label Spare parts catalogue Hydraulic test certificate 4 adjustable feet 9 9The second anode for installation instead of the inspection flange is supplied separately and must...

Page 12: ...since it can become a potential hazard Dispose of packaging material in compliance with applicable legislation MODELS 7200 V Plus 800 to 1000 Make sure that any lifting equipment is of adequate capaci...

Page 13: ...V Plus storage cylinders can be installed in any room where there is no specific requirement for an electrical protection rating higher than IP X0D 0 4 m 0 6 m 0 3 m 0 4 m 9 9Respect the minimum speci...

Page 14: ...its have been bled Turn the main power switch OFF and make sure that the water heating system shuts down completely Provided the above checks have been completed satisfactorily restart the system and...

Page 15: ...cleaning product Dry the storage cylinder after cleaning it 0 0Do not use abrasive products petrol or triethylene INTERNAL CLEANING MODELS 7200 V Plus 200 to 550 Removing and checking the magnesium a...

Page 16: ...suitable wrench to unscrew the anode holder 6 Check the magnesium anode for wear and replace it if necessary On completion of cleaning follow the above steps in the reverse order to refit all removed...

Page 17: ...licable legislation 20 TROUBLESHOOTING FAULT CAUSE SOLUTION The storage cylinder functions incorrectly or irregularly Flow rate too high Fit a pressure limiter Fit a flow reducer There are blockages o...

Page 18: ...will remain above ZERO simply adjust the storage cylinder s thermostat to its minimum temperature 9 9If outdoor temperature may drop below ZERO risk of freezing performtheoperationsdescribedinthe Prep...

Page 19: ...19 END USER END USER...

Page 20: ...el 0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore...

Reviews: