background image

2

 

 

RANGE

MODEL (Hot-cold version)

CODE

RIELLO 7000 ACI 800 PLUS

20137619

RIELLO 7000 ACI 1000 PLUS

20137620

RIELLO 7000 ACI 1500 PLUS

20137622

RIELLO 7000 ACI 2000 PLUS

20137624

MODEL (Cold version)

CODE

RIELLO 7000 ACI 800 PLUS C

20136268

RIELLO 7000 ACI 1000 PLUS C

20136269

RIELLO 7000 ACI 1500 PLUS C

20136270

RIELLO 7000 ACI 2000 PLUS C

20136271

ACCESSORIES

For a complete list of accessories and details of their compatibil-

ity, refer to the Catalogue.

ENGLISH

Dear heating engineer,

We would like to congratulate you on having recommended a 

R

 buffer tank unit: a modern product that's capable of en-

suring a high degree of reliability, efficiency, quality and safety.

While your technical skills and knowledge will certainly be more 

than sufficient, this booklet contains all the information that 

we have deemed necessary for the device's correct and easy in-

stallation.

Thank you again, and keep up the good work,

Riello S.p.A.

CONFORMITY

R

 buffer tanks conform to EN standard 10025.

Summary of Contents for 7000 ACI 60 PLUS

Page 1: ...cod Doc 0072586 rev 6 09 2017 7000 ACI PLUS EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Page 2: ...ories and details of their compatibil ity refer to the Catalogue ENGLISH Dear heating engineer We would like to congratulate you on having recommended a R buffer tank unit a modern product that s capa...

Page 3: ...autions 4 3 Description of the appliance 5 4 Identification 5 5 System layout 5 6 Technical specifications 6 7 Location of sensors 6 8 Overall dimensions and water fittings 7 INSTALLER 9 Unpacking the...

Page 4: ...and must ALWAYS accompany the product even if it is sold to another owner or transferred to another user or to another installation If you lose this manual or der a replacement immediately Keep the p...

Page 5: ...HER Modell Seriennummer Kode Baujahr Stromversorgung V Hz Speicherinhalt l 067670DE Erdschluss ist Vorschrift Obligatory ground connection Aarding verplicht W Stromaufnahme Max Betriebsdruck Speicher...

Page 6: ...r without insulation 790 790 1000 1100 mm Height with insulation 1725 1975 2090 2405 mm Height without insulation 1725 1975 2090 2405 mm Insulation thickness 30 mm Maximum operating pressure 6 bar Max...

Page 7: ...ent not supplied 1 1 2 F 2 F MI CH flow 3 F 4 F RI CH return 3 F 4 F SC Drain 1 F RC Return to boiler 3 F 4 F MC Outlet from boiler 3 F 4 F A 220 220 250 250 mm B 355 355 415 415 mm C 905 1030 1080 12...

Page 8: ...1500 1200 1200 2315 213 2000 1300 1300 2630 335 7000 ACI PLUS C A B H Gross weight kg 800 900 900 1875 112 1000 900 900 2125 168 1500 1200 1200 2240 190 2000 1200 1200 2555 305 10 HANDLING Once you ha...

Page 9: ...ks Make sure that the system is fitted with safety and con trol devices in accordance with applicable legislation and standards Make sure that the central heating circuit has been flushed out to remov...

Page 10: ...act on the environment and save energy before leaving for the weekend or a short break etc provided outdoor temperatures will remain above ZERO simply adjust the buffer tank s temperature control devi...

Page 11: ...Fit a pressure limiter Fit a flow reducer There are blockages or deposits in the buffer tank Check and clean as necessary Filling pump not functioning Check the pump The water temperature from the bo...

Page 12: ...The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice...

Reviews: