Riello 7200/2 HV PLUS

DESCRIPTION

7200/2

1500 HV PLUS

7200/2

2000 HV PLUS

Cylinder type

Vitrified

Cylinder layout

Vertical

Heat exchangers layout

Vertical

Cylinder diameter with insulation

1200

1300

mm

Cylinder diameter without insulation

1000

1100

mm

Height with insulation

2185

2470

mm

Insulation thickness

100

mm

First magnesium anode (Ø x length)

32 x 700

mm

Second magnesium anode (Ø x length)

32 x 400

mm

Flange diameter

290/220

mm

Probe socket diameter

8

8

mm

Electric resistor socket (not supplied)

1"1/2

1"1/2

Ø

Lower coil water content

19,4

28,1

l

Upper coil water content

10,4

16,9

l

Lower coil heat exchange surface

3,4

4,6

m2

Upper coil heat exchange surface

1,8

2,8

m2

Lower coil absorbed power (*)

88

120

kW

Upper coil absorbed power (*)

47

73

kW

DHW (*) - bottom coil

2200

2900

l/h

DHW (*) - top coil

1200

1800

l/h

Necessary capacity heat exchanger – lower coil (*) 

3,8

5,2

m3/h

Necessary capacity heat exchanger – upper coil (*)

2,0

3,1

m3/h

Storage cylinder maximum operating pressure

8

8

bar

Coils maximum operating pressure

6

6

bar

Maximum operating temperature

99

99

°C

Net weight with insulation

330

544

kg

Useful volume

1390

1950

I

Dispersion

250

305

W

6

7,32

kWh/24h

Insulation type

Soft PU shells

Useful non-solar volume (Vbu)

525

800

l

(*) According to DIN 4708, to get domestic hot water with 

Δ

T 20°C (80°/60°C)  on the heat-exchanger, please observe the values showed in the datasheet 

concerning absorbed power and necessary capacity heat-exchanger.  

4   Technical data

3   Product description

The solar storage cylinders Riello 7200/2 HV PLUS can be 

integrated into solar systems for the production of do-

mestic hot water.

The main technical elements of the design of the solar 

storage cylinder are:

- the careful study of the geometries of the tank and the 

coils that allow you to obtain the best performance in 

terms of stratification, heat exchange and reactivation 

times

- the regulation of the connections to various heights for 

employing various types of heat generators, without 

influencing the stratification

- the polyurethane insulation without any CFC and the 

elegant outer covering to limit dispersion and to im-

prove efficiency

- the use of the flange to facilitate cleaning and mainte-

nance, and the magnesium anode with an "anti-corro-

sion" function

The Riello 7200/2 HV PLUS storage cylinders can be equipped 

with a specific solar regulator and they can easily be in-

serted into solar system where the boilers or thermal sys-

tems act as auxiliary producers of heat.

Summary of Contents for 20052784

Page 1: ...cod 20055743_EN rev 2 05 2016 Solar storage cylinders 7200 2 1500 2000 HV PLUS EN INSTALLATION INSTRUCTIONS...

Page 2: ...ternal components 11 14 Recycling disposal 11 Index Dear Installer thank you for choosing a Riello 7200 2 HV PLUS solar stor age cylinder a modern high quality product providing you with the utmost we...

Page 3: ...operations be carried out Drain the solar heating circuit Close the shut off devices of the water system Switch off the boiler as described in the appli ance s instruction booklet Turn off the system...

Page 4: ...ersion 250 305 W 6 7 32 kWh 24h Insulation type Soft PU shells Useful non solar volume Vbu 525 800 l According to DIN 4708 to get domestic hot water with T 20 C 80 60 C on the heat exchanger please ob...

Page 5: ...4500 5000 5500 6000 Mod 1500 Mod 2000 Pressure drop TOP COIL Pressure drop BOTTOM COIL PRESSURE DROP mbar FLOW RATE l h PERDITA DI CARICO mbar PORTATA l h 600 650 700 550 500 450 400 350 300 250 200...

Page 6: ...ric resistor socket not supplied AD1 AD2 Magnesium anode 1500 HV PLUS 2000 HV PLUS The solar storage cylinder Riello 7200 2 HV PLUS is not equipped with load circulators which should be appropriately...

Page 7: ...rain 1 1 2 F 1 1 2 F Psc Diameter length boiler probe socket 1 2 F 1 2 F mm Psr Diameter length solar regulator probe socket 1 2 F 1 2 F mm RE Electric resistor socket not supplied 1 1 2 F 1 1 2 F AD1...

Page 8: ...is an integral part of the storage cylinder and it is recommended that it be read and kept safe INSTALLING THE MAGNESIUM ANODES Proceed as follows to install the magnesium anodes Remove the protectiv...

Page 9: ...e solar heating circuit is completely vented The cold pressure of the equipment is about 3 bar The safety valves intervenes at 6 bar The piping of the hydraulic supply are insulated in full respect of...

Page 10: ...he proce dure reported above is difficult to do Periodic maintenance which is essential for safety purposes the efficiency and the life of the solar storage cylinder provides reduced consumption and k...

Page 11: ...nesium anode and replace it if necessary Once the cleaning operations are finished reassemble all the components following the above instructions in the reverse order NOTE the tightening torque of the...

Page 12: ...0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore lia...

Reviews: