![Riello 20023353 Installation Instructions Manual Download Page 6](http://html.mh-extra.com/html/riello/20023353/20023353_installation-instructions-manual_1460088006.webp)
6
GENERAL INFORMATION
COLLECTOR WIND AND SNOW LOADING CHART
(Calculated for standard, zone 1 wind loads and snow loads)
Installation
height above
ground (m)
Site’s wind
exposure
Mass in kg to secure collector
against lifting by wind
Altitude
(m.a.s.l.)
Total load on roof from wind
and snow loads and collector
weight (kg)
At angle of
45°
At angle of
20°
At angle of
45°
At angle of
20°
CSV 25 R
0-10
low
60
40
100
424
546
10-20
low
80
50
250
595
773
0-10
medium
80
70
100
396
510
10-20
medium
90
80
250
533
691
CSV 35 R
0-10
low
90
80
100
599
771
10-20
low
110
100
250
841
1093
0-10
medium
110
100
100
561
720
10-20
medium
130
120
250
753
976
9
These specifications are purely indicative. The entire structure must be inspected by an expert in static loading in compliance
with applicable standards.