POSITIONING THE SENSORS

Tm

TeB

TB

TeC

TL90

TL82

TR TS

TA

AE

RI

MI

PI

TBOX BASIC ACS

Caldaia

Bollitore

MB

RB

PB

20

40

60

80
100

0

120

20

40

60

80
100

0

120

Tm  - Minimum temperature thermostat sensor 
TS  - Safety thermostat sensor 
TL90  - Boiler overtemperature dispersal thermostat sensor 
TL82  - Maximum temperature thermostat sensor 
TR  - Boiler control thermostat sensor 
TB  - Storage cylinder control thermostat sensor 
TeC  - Boiler temperature gauge sensor 
TeB  - Storage cylinder temperature gauge sensor

TA  - Room thermostat  
AE  - 230V~50Hz electrical power supply 

MI  - CH flow  
RI 

- CH return 

PI 

- CH pump 

MB  - Storage cylinder delivery 
RB  - Storage cylinder return 
PB  - Storage cylinder pump

Refer to the manual supplied with the boiler to identify the sensor sockets correctly. 

Insert the thermostat sensors in the corresponding sockets and fix them securely in place. Use the cable 
straps provided to secure the sensor cables. 

Boiler

Storage cylinder

Summary of Contents for 20017207

Page 1: ...TBOX BASIC ACS USE INSTALLATION AND MAINTENANCE MANUAL...

Page 2: ...ity to European Directive 2006 95 EC Low Voltage and to the following European standards EN 60730 1 2000 Automatic electrical controls for household and similar use EN 60730 2 9 2000 Part 2 Particular...

Page 3: ...ide comfort in the home for many years to come This manual provides information that is essential to the instal lation of the appliance Used in conjunction with your own knowledge and expertise it wil...

Page 4: ...tallation 9 Accessing internal components 11 Electrical connections 12 Positioning the sensors 13 Wiring diagrams 14 Layout 15 Description of functions 16 Useful information 18 This manual Code 200206...

Page 5: ...instruction manual is an integral part of the product It must be kept safe and must ALWAYS accompany the product even if it is sold to another owner or transferred to another user or to another instal...

Page 6: ...re housed in an ABS box and protected by a cover All the electrical control and safety devices in TBOX BASIC ACS control panels are factory tested in com pliance with applicable technical standards Co...

Page 7: ...linder control thermostat TB field of adjustment 0 70 3 C Minimum temperature thermostat Tm Control range 30 90 3 C Working setting 40 C Maximum temperature thermostat TL82 Control range 30 90 3 C Wor...

Page 8: ...ains the instruction manual TABLEAU DE CONTROLE CONTROL PANEL PANNELLO DI CONTROLLO SCHALTTAFEL CUADRO DE MANDO 20 Kg max B A D C G E F H 20 40 60 80 100 0 120 20 40 60 80 100 0 120 Description A 348...

Page 9: ...LE Pannellatura SUPERIORE Lato ANTERIORE della CALDAIA LATERALE della CALDAIA LATERALE della CALDAIA Once you have identified the right holes for the type of installation required proceed as follows P...

Page 10: ...0 0 12 0 20 40 60 80 10 0 0 12 0 20 40 60 80 10 0 0 12 0 20 40 60 80 10 0 0 12 0 VERTICAL installation to sensor socket in boiler Before you can install the control panel on a boiler side panel proce...

Page 11: ...components inside the control panel Turn the system OFF at the mains power switch Remove the top panel 1 by pulling it outwards 1 bCarefully unwind the thermostat cables and route them through the re...

Page 12: ...and screw up the cable glands to secure the cables against pulling Secure the cables to the casing of the boiler as neces sary bUse the terminals provided to connect all 230 V power users to ground a...

Page 13: ...nsor TB Storage cylinder control thermostat sensor TeC Boiler temperature gauge sensor TeB Storage cylinder temperature gauge sensor TA Room thermostat AE 230V 50Hz electrical power supply MI CH flow...

Page 14: ...50Hz power supply FU Fuse 6 3 A T IP Main switch TS Manual reset safety thermostat 110 C TR Boiler control thermostat 30 82 C TB Storage cylinder control thermostat 0 70 C Tm Minimum temperature ther...

Page 15: ...82 C 5 Boiler temperature gauge 6 Storage cylinder temperature gauge 7 Storage cylinder control thermostat 0 70 C 8 Fuse 9 Burner lockout indicator 10 Two pole ON OFF switch 11 Boiler overtemperature...

Page 16: ...rature between 60 and 82 C The recommended set ting is around 70 C Storage cylinder control thermostat v The storage cylinder control thermostat lets you adjust domestic hot water temperature between...

Page 17: ...requires a suitable tool and is reserved for personnel from THERMITAL s Technical Assistance Service Maximum temperature thermostat TL82 This thermostat cuts in at 82 C during the DHW produc tion cyc...

Page 18: ...SELLER Mr Address tel TECHNICAL ASSISTANCE SERVICE Mr Address tel BOILER DETAILS From Data label Make Type Serial number Date of initial start up INSTALLER Mr Address tel CONTROL PANEL DETAILS From pr...

Page 19: ......

Page 20: ...5 Legnago VR www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical speci cations standard equipment and accessories are therefore liable to mod...

Reviews: