Riello 20010820 Installation, Operation And Maintenance Manual Download Page 11

11

Carefully unwind the thermostat cables and route them 
through the relevant grommets. Insert the thermostat 
sensors in the corresponding sockets in the boiler. Fix the 
sensors securely in place. Use the cable straps provided 
to secure the sensor cables. 

Spring clip 

Cable 

Sensor 

r

Radius  

 20 mm

Sensor socket 

Only personnel from Riello’s Technical Assistance Service 
or professionally qualified heating engineers are allowed 
to access components inside the control panel. 

Proceed as follows if you need to access components 
inside the control panel: 

-  Turn the system OFF at the mains power switch

-  Remove the top panel (1) by pulling it outwards.

1

ACCESSING INTERNAL COMPONENTS

Summary of Contents for 20010820

Page 1: ...CONTROL PANEL RIELLOtech PRIME INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Page 2: ...ltage Directive 2006 95 EC ex Directive 73 23 EEC Electromagnetic Compatibility Directive 2004 108 EEC ex Directive 89 336 EEC EN 61000 6 2007 parts 1 2 3 4 EN 60730 1 2002 EN 60730 2 9 2003 CONFORMIT...

Page 3: ...ice and to provide comfort in the home for many years to come This manual provides information that is essential to the installation of the appliance Used in conjunction with your own knowledge and ex...

Page 4: ...actions that you MUST NOT do CONTENTS General Safety Information 5 Precautions 5 Product description 6 Identification 6 Technical specifications 7 Accessories 7 Unpacking the product 8 Dimensions and...

Page 5: ...tion manual is an integral part of the product It must be kept safe and must ALWAYS accompany the product even if it is sold to another owner or transferred to another user or to another installation...

Page 6: ...PRIME control panels are identified by TABLEAU DE CONTROLE CONTROL PANEL PANNELLO DI CONTROLLO SCHALTTAFEL CUADRO DE MANDO 20 Kg max l Etichetta Caratteristiche Tecniche il N di codice riportato sull...

Page 7: ...s 230 V Manual reset safety thermostat TS 110 0 6 C Control thermostat TR field of adjustment 30 82 3 C Minimum temperature thermostat Tm control range 30 90 3 C working setting 40 C Boiler temperatur...

Page 8: ...a cardboard box that also contains the instruction manual TABLEAU DE CONTROLE CONTROL PANEL PANNELLO DI CONTROLLO SCHALTTAFEL CUADRO DE MANDO 20 Kg max B A D C G E F H 20 40 60 80 100 0 120 Descriptio...

Page 9: ...n check the arrangement of the holes on the top panel or side panel of the boiler Once you have identified the right holes for the type of installation required proceed as follows Push out the pre for...

Page 10: ...proceed as follows Remove the 4 screws A Remove the front trim B turn it through 180 and fit it back on the body of the control panel C Install the control panel as instructed above VERTICAL installat...

Page 11: ...the sensor cables Spring clip Cable Sensor r Radius 20 mm Sensor socket Only personnel from Riello s Technical Assistance Service or professionally qualified heating engineers are allowed to access co...

Page 12: ...n on how to connect up the individual devices Tighten the screws on the cable clamps and screw up the cable glands to secure the cables against pulling Secure the cables to the casing of the boiler as...

Page 13: ...rmostat sensor TeC Boiler temperature gauge sensor TA Room thermostat AE 230V 50Hz electrical power supply MI CH flow RI CH return PI CH pump bRefer to the manual supplied with the boiler to identify...

Page 14: ...3 TA FU WIRING DIAGRAMS L1 N PE 230V 50Hz power supply FU Fuse 6 3 A T IP Main switch TS Manual reset safety thermostat 110 C TR Control thermostat 30 82 C Tm Minimum temperature thermostat 30 90 R40...

Page 15: ...urner lockout indicator 7 Two pole ON OFF switch 8 Minimum temperature thermostat sensor Tm accessible from inside 9 Safety thermostat sensor TS 10 Control thermostat sensor TR 11 Boiler temperature g...

Page 16: ...er and press the button Use a suitable tool if necessary bIf the safety thermostat TS shuts down the burner the red warning light comes on and any burner error signals on the burner controller are los...

Page 17: ...ECHNICAL ASSISTANCE SERVICE Mr Address tel BOILER DETAILS From Data label Make Type Serial number Date of initial start up INSTALLER Mr Address tel CONTROL PANEL DETAILS From product label Serial numb...

Page 18: ...18...

Page 19: ......

Page 20: ...At the end of its working life the product cannot be disposed of as municipal waste It can be delivered to separate waste collection centres operated by local councils if such exist or to the reselle...

Reviews: