2401
5
GB
ELECTRICAL WIRING
S7029
Bro
wn
White
(50V)
Blue
Motor
Capacitor
Limit thermostat
Neutr
al
Main switch
T6A
N
L
M
~
Black
NOTES
– Wires of min. 1 mm
2
section.
(Unless requested otherwise by local standards
and legislation).
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
– To remove the control-box from the burner,
loosen screw (A)
(see figure) and pull towards
the arrow.
– The photoresistance is fitted directly into the
control-box
(underneath the ignition-transformer)
on a plug-in support.
TESTING
Check the shut-down of the burner by opening
the thermostats.
CARRIED-OUT IN THE FACTORY
WARNING
DO NOT EXCHANGE THE
220V
~
60Hz
N
L
Safety thermostat
Remote lock-out signal
(220V - 0.5A max.)
1
2
3
4
5
6
7
8
9
Blue
Bro
wn
Terminal board of
control-box 530SE
*
Valve
T
T
RUN OF THE ELECTRICAL CABLE
1 - Cable grommet
N - Neutral
2 - Cable-clamp
L - Phase
3 - Terminal board
- Burner-earth
D5228