16-
- condensation evaporation with hot gas (saddle model H, wall W and ceiling D)
- for the unit GEKN 2000-3000, the oil heating in the compressor is standard equipment.
The unit comes factory made with tubing according to VBG 20, wired according to VDE
regulations, equipped with 2.5 m connecting cable and a shock-proof plug and filled with a
hydrocarbon refrigerant.
Weight of the integrated refrigeration units:
Integrated
refrigeration GEK..-
N
0600
N
0900
N
1200
N
1500
N
2001
N
3001
T
0501
T
0701
T
1001
T
1201
T
1501
..-H/..-W/..-S *)
Weight (kg)
net
gross
43
60
51
68
54
71
55
72
76
104
82
110
45
62
48
76
68
96
72
100
89
117
..-D *)
Weight (kg)
net
gross
55
79
61
85
66
90
67
91
92
123
102
133
55
79
62
86
92
113
83
114
103
134
*) model type ..-H: piggyback (saddle)
..-W:
wall
unit
..-S: split unit
..-D:
ceiling
unit
Attention: Observe the load-bearing capacity of the refrigeration cell walls!
9) Stopping operation of the refrigeration unit
During long periods of stoppage or cleaning, the refrigeration unit is to be shut down by pulling
the power plug. For restarting the units with oil sump heating, the time of start-up is to be noted.
Notice: After a power failure, the refrigeration unit starts up automatically.
All saved data is retained.
10) Energy saving instructions
- The refrigeration unit should not be placed near sources of heat. If there are high ambient
temperatures, the unit switches on too often.
- Direct sunlight increases the use of electricity.
- Avoid unnecessary and prolonged opening of the door.
- Refrigeration unit should be cleaned regularly. A clean unit saves energy and has a longer
life.
11) Cleaning and maintenance
-
With the exception of occasional cleaning of the condenser, and perhaps the
evaporator, the unit is maintenance free.
- The refrigeration unit should be checked and cleaned 12 to 18 weeks after operational
start-up at the latest. Depending on the degree of soiling, the time interval up to the next
check or cleaning can then be determined. The time interval for cleaning depends on the
ambient conditions.