ARTIST m – Instalation Guide 2.3 – 12.06.2003
11
Connection to GPI Input / Output Contacts
Eg. External 5V relays
Eg. external contacts
4 +5V
*
4 +5V
*
Notes:
•
The carrying capacity of Pin 4 totals 50 mA
•
The contact carrying capacity of the outputs is 300 mA
(protected by self resetting fuse)
•
The voltage on the GPI Inputs totals 5 - 48 V
•
The bond strength for GPI Output is max. 60V
•
* n.c. = not Connected
Front view of the connectors
requires GPI-Option RCP-GPI-E