Operating faults/service
Rieber GmbH & Co. KG
13
8 Operating
faults/service
DANGER!
Danger of electric shock. Dangerous electrical voltage.
►
Only allow electrical repairs to be carried out by an electrician.
Fault
Possible cause
Rectification
The device does not work
Plug has no power
¾
Connect another device and
see if this is working.
No vacuum is generated
The container is too full
¾
Allow a space at the top of the
container of at least 3 cm.
The foodstuff has not cooled down
sufficiently.
¾
Cool down the foodstuff in
advance, for example by
placing it in the fridge.
The edge of the container or seal of
the lid on the vacu
lid
®
- is dirty or
damaged
¾
Clean
¾
Replace the damaged lid.
One of the two sealing rings on the
vacu
lid
®
adapter has come loose.
¾
Inspect.
¾
Replace missing seal.
Customer services, spare parts
See website
http://www.rieber.de
IMPORTANT
The customer services need the type and number of your device.
Disposing of the device
Your device is made of high-quality materials that can be re-used or recycled. Have the
device professionally disposed of by your local recycling unit.