background image

No. de 

12 galones

clave

No. de pieza

Descripción

1

813213

Interruptor de palanca

2

820563-4

Tornillo de cabeza troncocónica serrada tipo "AB" 10 x 3/4

3

829692

Ensamblaje del colector

4

509488

Flotador

5

823201-1

Jaula del filtro

6

826817

Tuerca hexagonal con pestaña 5/16-18

7

15534-1

Arandela

8

818413-2

Rueda del soplador

9

818961

Separador

10

820563-5

Tornillo de cabeza troncocónica serrada tipo “AB” 10 x 1-1/4

11

VF4000

Filtro

12

73317

Placa del filtro

13

73316

Tuerca del filtro

14

73185

Tapa del drenaje

15

828833

Pata para ruedecilla con área de almacenamiento

16

331605

Ruedecilla

17

VT2509

Boquilla utilitaria

18

VT2503

Boquilla para auto

19

VT2510

Boquilla para mojado

20

VT2508

Tubos extensores

21

826356-1

Ensamblaje de la manguera  (incluye los Nos. de clave 22 a 24)

22

826355-1

Lengüeta de resorte

23

826354

Extremo de manguera con enclavamiento 

24

815096

Adaptador de manguera 

25

SP6663

Manual del operador

* Artículo de herraje estándar. Puede comprarse localmente.

† Estas piezas de repuesto se encuentran disponibles en el establecimiento donde compró la aspiradora.

26

*

*

Piezas de repuesto

Aspiradora para mojado/seco de 12 galones EE.UU.

Números de modelo WD12500 

Las piezas RIDGID se encuentran disponibles en línea conectándose a www.ridgidparts.com

Pida siempre por número de pieza —no por número de clave

ADVERTENCIA

SERVICIO DE AJUSTES Y REPARACIONES DE UNA ASPIRADORA PARA

MOJADO/SECO CON AISLAMIENTO DOBLE

En una aspiradora para mojado/seco con aislamiento doble se proporcionan dos sistemas de aislamiento en
vez de conexión a tierra. No se proporciona ningún medio de conexión a tierra en un aparato electro-
doméstico con aislamiento doble, ni se debe añadir a éste ningún medio de conexión a tierra. El servicio de
ajustes y reparaciones de una aspiradora para mojado/seco con aislamiento doble requiere extremado
cuidado y conocimiento del sistema, y debe ser realizado únicamente por personal de servicio competente.
Las piezas de repuesto para la aspiradora para mojado/seco con aislamiento doble deben ser idénticas a las
piezas que reemplazan. La aspiradora para mojado/seco con aislamiento doble está marcada con las
palabras “DOUBLE INSULATED” (con aislamiento doble) y puede que el símbolo          (un cuadrado dentro
de un cuadrado) también esté marcado en los aparatos.

Para reducir el riesgo de lesiones por causa de descargas eléctricas, desenchufe el cordón de energía antes
de hacer servicio de ajustes y reparaciones a las piezas eléctricas de la aspiradora para mojado/seco.

!

SP6663-2 12 GALLON.qxd  4/21/08  10:40 AM  Page 26

Summary of Contents for WD1250

Page 1: ...tor s manual before using this product Thank you for buying a RIDGID product WD1250 12 U S GALLONS 45 LITERS WET DRY VAC FOR QUESTIONS OR INFORMATION CONTACT US AT CALL 1 800 4 RIDGID 1 800 474 3443 O...

Page 2: ...nning while unattended you may fail to notice important signs indicating abnormal operation such as loss of suction debris liquid exiting exhaust or abnormal motor noises Immediately stop using Vac if...

Page 3: ...r pull cord around sharp edges or corners Do not run Vac over cord Keep cord away from heated surfaces Do not handle plug switch or the Vac with wet hands Do not put any object into ventilation openin...

Page 4: ...each item against the Carton Contents List Contact 1 800 4 RIDGID or E mail us at info ridgidvacs com if any parts are damaged or missing 1 Turn the dust drum upside down on the floor 2 Insert the cas...

Page 5: ...opening in the center of the lid with the words This Side Towards Lid laying face down over the hole 4 Line up filter cage tabs with slots in the center ring of the lid 5 Push on the filter cage until...

Page 6: ...or use Wet Dry Vac Assembly Drum Out Flexible Locking Tab Drum Channel Top Assembly Push Down Pull Out Flexible Locking Tab Push Down Pull Out Flexible Locking Tab Cord Storage Simply wrap the power c...

Page 7: ...r abnormal motor noises Immediately stop using Vac if you notice these signs Do not leave Vac plugged in when not in use Do not continue running when float has cut off suction Do not operate Vac in ar...

Page 8: ...otor noise will become higher in pitch due to increased motor speed When this happens turn off the vac unplug the power cord and empty the drum 4 After using the vac to pick up liquids the filter must...

Page 9: ...ac Should it become necessary to pick the vac up to move it the handles on the sides of the dust drum are used to lift To maneuver the vac the pull handle above the inlet should be used Blowing Featur...

Page 10: ...ARNING To reduce the risk of injury from accidental starting unplug power cord before changing or cleaning filter NOTE The filter is made of high quality paper designed to stop very small particles of...

Page 11: ...aces of the drum 3 Empty drum after 20 minutes Rinse with water until bleach smell is gone Allow drum to dry completely before sealing the motor on the drum Storage Before storing your vac the dust dr...

Page 12: ...are provided instead of grounding No grounding means is provided on a double insulated appliance nor should a means for grounding be added Servicing a double insulated Wet Dry Vac requires extreme ca...

Page 13: ...ons Wet Dry Vac Model Number WD12500 RIDGID parts are available on line at www ridgidparts com 13 23 16 15 14 12 11 17 18 19 20 5 4 3 6 7 8 2 10 9 25 22 21 24 1 13 SP6663 2 12 GALLON qxd 4 21 08 10 40...

Page 14: ...idge Tool Company s option and returned at no charge or if after three attempts to repair or replace during the warranty period the Wet Dry Vac is still defective you can elect to receive a full refun...

Page 15: ...I N CONT CTENOS LLAMANDO AL 1 800 4 RIDGID 1 800 474 3443 O CONECT NDOSE A www ridgidvacs com GUARDE ESTE MANUAL PARA REFERENCIA FUTURA ADVERTENCIA Para reducir el riesgo de lesiones el usuario debe l...

Page 16: ...as se ales Las chispas que se producen en el interior del motor pueden incendiar los vapores inflamables o el polvo Para reducir el riesgo de incendio o explosi n No recoja con la aspiradora l quidos...

Page 17: ...etos extra os hacia los ojos lo cual puede causar da os graves en los ojos Esta aspiradora para mojado seco tiene aislamiento doble lo cual elimina la necesidad de un sistema independiente de conexi n...

Page 18: ...uese con nosotros por correo electr nico conect ndose a info ridgidvacs com si alguna pieza est da ada o falta Desempaquetado y comprobaci n del contenido de la caja de cart n 1 Ponga el tambor para p...

Page 19: ...la del filtro siga las instrucciones de ensamblaje que se dan a continuaci n 3 Coloque el flotador sobre la abertura que est en el centro de la tapa con las palabras This Side Towards Lid Este lado ha...

Page 20: ...edor del cabezal del motor y acople a presi n el conector que est en el enchufe a una vuelta del cord n Introduzca la manguera Introduzca el extremo que tiene el bot n pulsador de la manguera de arras...

Page 21: ...estas se ales No deje la aspiradora enchufada cuando no se est utilizando No contin e usando la aspiradora cuando el flotador haya cortado la succi n No utilice la aspiradora en reas con gases inflam...

Page 22: ...iltro Recogida de l quidos con la aspiradora 1 Al recoger peque as cantidades de l quido se podr dejar puesto el filtro 2 Al recoger grandes cantidades de l quido recomen damos quitar el filtro Si no...

Page 23: ...a boquilla para auto en el tubo extensor 4 Encienda la aspiradora y estar listo para usarla como soplador ADVERTENCIA Para reducir el riesgo de que se produzcan lesiones en la espalda o ca das no leva...

Page 24: ...adora est apagada 2 Para obtener ptimos resultados de limpieza debido a la acumulaci n de polvo limpie el filtro en un rea abierta La limpieza SE DEBE realizar al aire libre y no en el interior de la...

Page 25: ...tambor 3 Vac e el tambor despu s de 20 minutos Enju guelo con agua hasta que el olor a blanqueador desaparezca Deje que el tambor se seque comple tamente antes de sellar el motor sobre el tambor Alma...

Page 26: ...2500 Las piezas RIDGID se encuentran disponibles en l nea conect ndose a www ridgidparts com Pida siempre por n mero de pieza no por n mero de clave ADVERTENCIA SERVICIO DE AJUSTES Y REPARACIONES DE U...

Page 27: ...es EE UU N meros de modelo WD12500 Las piezas RIDGID se encuentran disponibles en l nea conect ndose a www ridgidparts com 13 23 16 15 14 12 11 17 18 19 20 5 4 3 6 7 8 2 10 9 25 22 21 24 1 27 SP6663 2...

Page 28: ...con la garant a Algunos estados no permiten la exclusi n o limitaci n de los da os fortuitos o emergentes por lo que es posible que la limitaci n o exclusi n que antecede no tenga aplicaci n en su ca...

Reviews: