RIDGID RP 300 Operating Instructions Manual Download Page 2

• Press the ON/OFF switch (fig.1, ref.3) to start the press fit cycle.

Important: Keep fingers and hands away from jaws during pressing

cycle!

• Wait until the complete pressing cycle has been completed.
• The tool features an automatic pressing facility.  This ensures a full

pressing cycle at all times

Important: In order to ease the load of the machine in a dangerous
situation you should firmly press the yellow pressure relief button
(Fig. 1 ref. 5). The hydraulic pressure decreases, the piston retracts
and the pressure on the tool as well as the jaw will be relieved.

TROUBLESHOOTING

• If a power failure interrupts the pressing cycle, press the manual release 
switch (fig. 1, ref 4) to reopen the jaws and remove the tool from the pipe.
• Whenever a pressing cycle is not fully completed, either due to a power
failure or any other cause, the complete procedure must be repeated.
-It is strongly recommended to never attempt to repeat a pressing cycle that
has been interrupted. This may lead to damage to the joint and possible
leakage. The joint should be cut out and replaced by a new one.
-The use of jaws not specifically designed and approved for pressing the
fittings being used may lead to damage and incorrectly compressed fittings.

Contact your RIDGID Press Fit Service Centre for any malfunction not covered
in this instruction manual.

MAINTENANCE
Always disconnect the tool from the power supply before performing
any maintenance.

Daily

-Clean the Press Fit tool with a soft cloth. Clean rollers and lightly lubricate.
Do not use detergents to clean the crimping tool. Check the condition of the
cable and plug daily for damage, and if damage occurs do not use the tool
and have the line cord replaced with an identical part by an authorized
service station.

Every 12 months

-The press fit tool must be sent for inspection and maintenance to the nearest
authorized RIDGID Press Fit repair centre for safety reasons.
-The repair centre will fully overhaul the tool and inspect that it is operating
correctly.
-Any unauthorized modifications and/or repairs will invalidate the warranty.

Storage

-Before storing the tool for long periods clean the tool thoroughly and wipe
clean.
-Keep away the tool from moisture and heat, and do not expose the tool to
extreme temperatures.
-Keep away from children.
-The RIDGID Press Fit tool is made of numerous metal and plastic parts.
Ensure that the tool is correctly disposed of in accordance with local
regulations.

Manual RP 300

Problem

Remedy

Tool will not operate

Check cable is plugged in

Tool will not operate

Check power source

Tool will not operate

Check that lock pin is correctly inserted

Tool will not operate

Electric motor must come to complete stop

before new pressing is started

RP 300

Operating Instructions

Operating instructions

For your own safety and before using this equipment, read these

instructions and the accompanying safety booklet carefully.

If you are uncertain about any aspect of using this tool, contact your

RIDGID distributor for more information.

The RP 300 is designed for use with the majority of press fit jaws

available on the market. The tool is designed to make press fit

connections on couplings using jaws meeting the specifications of

the fitting manufacturer. The use of this tool for any other application

may damage the tool, jaws or fitting and/or cause personal injury.

Keep these instructions together with the tool

Specifications:

Model:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .RP 300
Length w/out jaws:   . . . . . . . . . . . . . . . . . . . . . . . . . . . .440 mm
Width:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 mm
Height:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180  mm
Weight: (including battery):   . . . . . . . . . . . . . . . . . . . . . . .5,5 kg

Technical data:   . . . . . . .Class II construction 230V, 2,8A, 600W
Crimping force:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Min. 32KN
Capacity:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 – 108 mm
Operating temperature range:   . . . . . . . . . . . . . . .-8°C to +50°C

Before using your RIDGID Press Fit tool:

• Check for any transport damage. Any damage should be reported 
immediately to the forwarders.
• Check that all parts are included with the Press Fit tool.
• Check that the correct power cord and plug for your supply has been fitted.
• Check that the voltage on the nameplate is the same as your supply

Any repairs or Service to the RIDGID Press Fit tool must only be made
by an approved RIDGID Press Fit Service Centre.

All people involved in the working process must keep hands and fingers away
from the jaws!  Unplug tool when not in use, before service or during setup or
accessory change.  Avoid unintentional starting.  Keep people away from
working area.

Explanation of pictograms

General warning symbol           Read manual                  Risk of crushing

! Do not operate the tool without a pressing jaw.  

The tool may be damaged.

OPERATING THE RP 300 PRESS FIT TOOL

Fitting of the jaws (see fig. 1)

• Pull out lock pin (fig. 1, ref. 1).
• Insert the correct jaw (fig.1, ref.2) (size and brand of the fitting) into the
jaw-mounting opening.
• Push in the lock pin.  The tool will not start if pin is not inserted correctly.

Performing the Press Fit action

• Check that the correct jaws have been fitted for the joint that is going to be

pressed.

• Connect the tool to a power source, and place the jaws over the fitting

Summary of Contents for RP 300

Page 1: ...RIDGE TOOL COMPANY RP 300 ...

Page 2: ...e tool is correctly disposed of in accordance with local regulations Manual RP 300 Problem Remedy Tool will not operate Check cable is plugged in Tool will not operate Check power source Tool will not operate Check that lock pin is correctly inserted Tool will not operate Electric motor must come to complete stop before new pressing is started RP 300 Operating Instructions Operating instructions F...

Page 3: ...stauschen Alle 12 Monate Das Presswerkzeug muss zur Inspektion und Wartung aus Sicherheitsgründen an das nächste RIDGID Presswerkzeug Servicecenter eingeschickt werden Das Servicecenter wird das Werkzeug komplett überholen und seine korrekte Arbeitsweise überprüfen RP 300 Betriebsanleitung Betriebsanleitung Lesen Sie diese Instruktionen und die beiliegende Sicherheitsbroschüre zu Ihrer eigenen Sic...

Page 4: ...ze fern und setzen es keinen extremen Temperaturen aus Halten Sie das Werkzeug außerhalb der Reichweite von Kindern Das RIDGID Presswerkzeug besteht aus vielen Metall und Kunststoffteilen Stellen Sie sicher dass es gemäß den örtlichen Richtlinien entsorgt wird RP 300 Instructions de commande Instructions de commande Pour votre propre sécurité lisez attentivement ces instructions et le dépliant de ...

Page 5: ... la sertisseuse Contrôlez quotidiennement l état du câble et de la fiche quant à la présence d éventuels endommagements si cela est le cas n utilisez pas l outil avant le remplacement du cordon d alimentation par un composant identique dans un centre de service approuvé Tous les 12 mois Pour des raisons de sécurité la sertisseuse doit être envoyée pour inspection et entretien auprès du centre de r...

Page 6: ...it te proberen een perscyclus die onderbroken werd te herhalen Dat kan leiden tot beschadiging van de verbinding en mogelijke lekken De verbinding moet verwijderd worden en vervangen worden door een nieuwe Het gebruik van klauwen die niet specifiek ontworpen en goedgekeurd zijn voor het persen van de gebruikte fittingen kan leiden tot beschadigingen en onjuist samengeperste fittingen Neem contact ...

Page 7: ...funziona Verificate che il cavo sia inserito Controllate la sorgente di alimentazione Assicuratevi che il perno di blocco sia inserito correttamente L attrezzo non funziona Il motore elettrico deve arrestarsi completamente prima di iniziare una nuova operazione di pressatura RP 300 Instrucciones de uso Instrucciones de uso Para su propia seguridad y antes de utilizar este equipo lea con atención e...

Page 8: ...l perno del cierre Fig 1 ref 1 Inserte la mordaza correcta Fig 1 ref 2 tamaño y marca de la instalación en la abertura de montaje de mordaza Empuje el perno de cierre La herramienta no se pondrá en marcha si el perno no está insertado correctamente Para realizar la acción de encastre a presión Compruebe que se hayan instalado las mordazas correctas para la junta que se vaya a presionar Enchufe la ...

Page 9: ...n eller service på RIDGID krympeverktøyet må kun utføres av et godkjent RIDGID Press Fit Service Centre av misstag Håll personer undan från arbetsområdet Förklaring av piktogrammen Verktyget får inte användas utan pressklo Verktyget kan skadas ANVÃNDNING AV RP 300 PRESSPASSNINGSVERKTYG Montering av klorna se fig 1 Drag ut låssprinten fig 1 nr 1 För in rätt klo fig 1 nr 2 med tanke på storlek och f...

Page 10: ... den rigtige strømkabel og stik er monteret så de passer til strømforsyningen Kontrollere at spændingen på typeskiltet svarer til den du bruger Alle som er involvert i arbeidsprosessen må holde hender og fingre unna kjevene Trekk ut verktøyet når det ikke er i bruk før service eller under montasje eller ved skifting av tilbehør Unngå utilsiktet start Pass på at det ikke oppholder seg noen i arbeid...

Page 11: ...tion eller vedligeholdelse af RIDGID presseværktøjet skal foretages af en autoriseret RIDGID serviceværksted Alle personer som er involveret i pressearbejdet skal holde hænder og fingre væk fra kæberne Tag stikket ud af kontakten når værktøjet ikke bruges inden eftersyn under opstillingen eller ved udskiftning af tilbehør Undgå at starte apparatet uforsætligt Hold folk væk fra arbejdsområdet Symbo...

Page 12: ...n puhdistukseen l Tarkasta kaapelin ja pistokkeen kunto päivittäin ja jos niissä esiintyy vikoja älä käytä työkalua ja vaihdata virtajohto välittömästi vastaavanlaiseen valtuutetussa huoltopisteessä Vuosittain Press Fit työkalu tulee lähettää turvallisuussyistä johtuen lähimpään viralliseen RIDGID Press Fit korjaamoon tarkastettavaksi ja huollettavaksi Korjaamossa työkalu huolletaan täysin ja tark...

Page 13: ...u a qualquer outra causa o procedimento completo deverá ser repetido É fortemente recomendado nunca tentar repetir um ciclo de prensagem que tenha sido interrompido Isto pode conduzir a danos na junta e possíveis fugas A junta deverá ser cortada e substituída por uma nova O uso de mandíbulas não especificamente concebidas e aprovadas para os acessórios de prensagem que estão a ser usados pode cond...

Page 14: ...Fig 1 ref 1 Fig 1 ref 2 Fig 1 Fig 1 ref 3 Fig 1 ref 4 ...

Page 15: ...Fig 2 ...