background image

999-998-285.10_REV. G

3

Personal Safety

Stay alert, watch what you are doing and use com-
mon sense when operating a power tool. Do not
use a power tool while you are tired or under the in-
fluence of drugs, alcohol, or medication.

A mo ment

of inattention while operating power tools may result in
serious personal injury.

Use personal protective equipment. Always wear
eye  protection.

Protective  equipment  such  as  dust

mask, non-skid safety shoes, hard hat, or hearing pro-
tection used for appropriate conditions will reduce per-
sonal injuries.

Prevent unintentional starting. Ensure the switch is
in  the  OFF  position  before  connecting  to  power
source and/or battery pack, picking up or carrying
the tool.

Carrying power tools with your finger on the

switch or energizing power tools that have the switch
ON invites accidents.

Remove any adjusting key or wrench before turning
the power tool ON.

A wrench or a key left attached to

a rotating part of the power tool may result in personal
injury.

Do not overreach. Keep proper footing and balance
at all times.

This enables better control of the  power

tool in unexpected situations.

Dress properly. Do not wear loose clothing or jew-
elry. Keep your hair, and clothing away from mov-
ing parts.

Loose clothes, jewelry, or long hair can be

caught in moving parts.

If devices are provided for the connection of dust

extraction and collection facilities, ensure these are
connected and properly used.

Use of dust collection

can reduce dust-related hazards.

Do not let familiarity gained from frequent use of

tools allow you to become complacent and ignore
tool safety principles.

A careless action can cause se-

vere injury within a fraction of a second.

Power Tool Use and Care

Do not force power tool. Use the correct power tool
for your application.

The correct power tool will do the

job better and safer at the rate for which it is designed.

Do not use power tool if the switch does not turn it
ON and OFF.

Any power tool that cannot be controlled

with the switch is dangerous and must be repaired.

Disconnect the plug from the power source and/or

the battery pack from the power tool before making
any adjustments, changing accessories, or storing

K-45 Drain Cleaning Machine 

power  tools.

Such  preventive  safety  measures  re-

duce the risk of starting the power tool accidentally.

Store idle power tools out of the reach of children
and do not allow persons unfamiliar with the power
tool or these instructions to operate the tool.

Power

tools are dangerous in the hands of untrained users.

Maintain power tools. Check for misalignment or
binding  of  moving  parts,  breakage  of  parts  and
any  other  condition  that  may  affect  the  power
tool’s op er ation. If damaged, have the power tool
repaired before use.

Many accidents are caused by

poorly maintained power tools.

Keep cutting tools sharp and clean.

Properly main-

tained cutting tools with sharp cutting edges are less
likely to bind and are easier to control.

Use the power tool, accessories and tool bits etc. in
accordance with these instructions, taking into ac-
count the working conditions and the work to be
performed.

The use of the power tool for operations dif-

ferent from those intended could result in a hazardous
situation.

Keep  handles  and  grasping  surfaces  dry,  clean
and free from oil and grease.

Slippery handles and

grasping surfaces do not allow for safe handling and
control of the tool in unexpected situations.

Service

Have your power tool serviced by a qualified repair
person  using  only  identical  replacement  parts.

This  will  ensure  that  the  safety  of  the  power  tool  is
maintained.

Specific Safety Information

WARNING

This  section  contains  important  safety  informa-
tion that is specific to this tool.

Read these precautions carefully before using the
K-45 Drain Cleaning Machine to reduce the risk of
electrical shock or other serious injury.

SAVE ALL WARNINGS AND INSTRUCTIONS

FOR FUTURE REFERENCE!

Keep this manual with machine for use by the operator.

Drain Cleaner Safety

Before using the tool, test the ground fault circuit in-
terrupter  (GFCI)  provided  with  the  power  supply
cord  to  insure  it  is  operating  correctly. 

A  properly

operating GFCI reduces the risk of electrical shock.

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Summary of Contents for 0095691386786

Page 1: ...K 45 Drain Cleaning Machine Fran ais 17 Castellano p g 35 Drain Cleaner Manual www calcert com sales calcert com 1 888 610 7664 0 5 10 15 20 25 30...

Page 2: ...ction 6 Machine and Work Area Set Up 7 Operating Instructions 8 Operation 9 Feeding The Cable Into The Drain 9 Maintenance Instructions 11 Cleaning 11 Cables 12 AUTOFEED 12 Changing Cables Changing In...

Page 3: ...hich is located on nameplate Serial No WARNING Read this Operator s Manual carefully before using this tool Failure to understand and follow the contents of this manual may result in electrical shock...

Page 4: ...oor use reduces the risk of elec tric shock If operating a power tool in a damp location is un avoidable use a ground fault circuit interrupter GFCI protected supply Use of a GFCI reduces the risk of...

Page 5: ...paired Disconnect the plug from the power source and or the battery pack from the power tool before making any adjustments changing accessories or storing K 45 Drain Cleaning Machine power tools Such...

Page 6: ...n cords Only grasp the rotating cable with gloves recom mended by the manufacturer Latex or loose fitting gloves or rags can become wrapped around the cable and may result in serious personal injury D...

Page 7: ...power unit The last 4 digits indicates the month and year of the manufacture 04 month 10 year Standard Equipment All K 45 Drain Cleaning Machines come with one pair of RIDGID Drain Cleaning gloves Th...

Page 8: ...RIEVE feed levers the slide chuck and the drum Presence and readability of the warning label see Figure 2 Any other condition which may prevent safe and normal operation If any problems are found do n...

Page 9: ...Catalog on line at RIDGID com 4 Confirm that the equipment to be used has been properly inspected 5 If needed place protective covers in the work area The drain cleaning process can be messy 6 Determ...

Page 10: ...ble attachments can be found in the RIDGID Catalog and on line at RIDGID com 9 If needed install the tool to the end of the cable The T slot coupler allows the cutting tool to be snapped into the cabl...

Page 11: ...et FOR REV refers to the cable ro tation and not to the direction of cable movement Do not rotate the cable in reverse except as specifi cally described in these instructions Running the drain cleaner...

Page 12: ...and prevent removal from the drain Minimize the amount of cable fed into the transition to prevent problems The cables are not attached to the inner drum Use care when feeding out the last 5 to 7 fee...

Page 13: ...ing does a better job of cleaning the drain and makes retrieving the cable easier Do not expose more than 12 30cm of cable The chuck can be used to better grip the cable during retrieval Move the hand...

Page 14: ...e 12B Figure 12A Removing AUTOFEED Screw Figure 12B Removing AUTOFEED Mechanism From Housing 3 Wipe or wash dirt and debris out of the AUTOFEED mechanism and hand grip 4 On the AUTOFEED mechanism appl...

Page 15: ...drum end of cable into hand grip opening and continue feeding entire cable into drum Figure 17 Figure 17 Loading Cable Without Changing Inner Drum Accessories WARNING The following RIDGID products hav...

Page 16: ...nd people unfamiliar with drain cleaners This machine can cause serious injury in the hands of untrained users Service and Repair WARNING Improper service or repair can make machine un safe to operate...

Page 17: ...y Ground Fault Circuit Interrupter GFCI Moisture in motor switch or on plug AUTOFEED full of debris AUTOFEED needs lubrication Cable not evenly distributed Do Not Force Cable Let the cutter do the wor...

Page 18: ...999 998 285 10_REV G 16 K 45 Drain Cleaning Machine www calcert com sales calcert com 1 888 610 7664 0 5 10 15 20 25 30...

Page 19: ...l pour future r f rence N de s rie AVERTISSEMENT Familiarisez vous bien avec le mode d emploi avant d utiliser l appareil L incompr hension ou le non respect des consignes ci apr s augmenteraient les...

Page 20: ...lable de l appareil 23 Pr paration de l appareil et du chantier 25 Consignes d utilisation 27 Fonctionnement de l appareil 27 Avancement du c ble 27 Consignes d entretien 30 Nettoyage 30 C bles 30 AUT...

Page 21: ...g s ou entortill s augmentent les risques de choc lectrique Lors de l utilisation d un appareil lectrique l ex t rieur pr voyez une rallonge lectrique appro pri e Les rallonges lectriques pr vues pour...

Page 22: ...n fr quente d un appareil vous rendre complaisant au point de n gliger les principes de s curit de base Le moindre faux pas peut se transformer en accident grave dans une fraction de seconde Utilisati...

Page 23: ...techniques RIDGID par mail adress rtctechservices emerson com ou bien en appelant le 800 519 3456 partir des Etats Unis ou du Canada exclusivement Consignes de s curit sp cifiques AVERTISSEMENT La sec...

Page 24: ...nt tre fournis au choix avec une tulipe de curage in corpor e ou un raccord rapide pour le montage des divers outils de curage Caract ristiques techniques Capacit de curage du K 45 Figure 1 D gorgeoir...

Page 25: ...de s cu rit des gants de curage RIDGID et les autres quipements de protection individuelle pr vus lors de l inspection du d gorgeoir Prot gez vous gale ment contre les produits chimiques et les bact r...

Page 26: ...appareil Signes d l ments endommag s us s manquants mal align s ou gripp s Libre mouvement et ou rotation des leviers d a vancement et de retrait du mandrin coulisse et du tambour Pr sence et de la l...

Page 27: ...de produits chim iques etc En pr sence de produits chimiques il importe de conna tre les mesures de s curit appli cables lors des travaux proximit de ceux ci Con sultez le fabricant du produit chimiqu...

Page 28: ...gnements visant les accessoires de c ble se trou vent dans le catalogue RIDGID en ligne RIDGID com 10 Le cas ch ant montez l outil en bout du c ble Le syst me de raccord rapide permet d embo ter tout...

Page 29: ...ez une longueur suffisante de c ble pour pouvoir l introduire dans l vacuation Poussez le c ble aussi loin que pos sible dans la canalisation Il faut au moins un pied de c ble l int rieur de la canali...

Page 30: ...m thode consiste en l utilisation de la marche arri re position REV pendant quelques secondes tout en appuyant sur le dos du c ble Ne laisser le c ble tourner en marche arri re que le temps n cessair...

Page 31: ...vous la section intitul e Retrait du c ble Proc dure en cas d entrave d un outil ou embout de c ble Si l embout du c ble cesse de tourner et ne peut pas tre retir du blocage l chez l interrupteur marc...

Page 32: ...ches d branchez l appareil Consignes d entretien AVERTISSEMENT Respectez les consignes d entretien suivantes afin de limiter les risques de choc lectrique br lure chimique et autres blessures L appar...

Page 33: ...on embout c t tambour comme indiqu la figure 15 Figure 15 Plissage de l embout de c ble 4 Enroulez le c ble dans le tambour interne EN SENS HORAIRE se reporter la figure 16 Figure 12B Retrait du m can...

Page 34: ...C 2IC C 22 C 23IC C 4 C 5 C 6 C 61C Cables 8 mm 5 16 a tulipe Description 15 4 6 m avec tulipe de curage 25 7 6 m avec tulipe de curage 35 10 7 m avec tulipe de curage 25 7 6 m avec tulipe de curage...

Page 35: ...aration de l appareil Consultez votre distributeur RIDGID Consultez les sites RIDGID com pour obtenir les co ordonn es de l interlocuteur RIDGID le plus proche Consultez les services techniques de RID...

Page 36: ...moteur Disjoncteur diff rentiel d fectueux Humidit dans moteur bo tier lectrique ou fiche lectrique AUTOFEED plein de d bris AUTOFEED en besoin de lubrification C ble mal enroul Ne forcez pas le c bl...

Page 37: ...ntra en su placa de caracter sticas No de serie ADVERTENCIA Antes de utilizar este aparato lea detenidamente su Manual del Operario Pueden ocurrir descar gas el ctricas incendios y o graves lesiones s...

Page 38: ...ones de funcionamiento 45 Funcionamiento 45 Alimentaci n del cable en el desag e 45 Instrucciones de mantenimiento 48 Limpieza 48 Cables 48 Autoalimentadora AUTOFEED 48 Reemplazo del cable Reemplazo d...

Page 39: ...lejado del calor aceite bordes cortantes o piezas m viles Un cord n enredado o en mal estado aumenta el riesgo de choques de electricidad El texto utilizado en la secci n de Advertencias de seguridad...

Page 40: ...orcionan dispositivos para conectar aparatos de extracci n y recolecci n de polvo asegure que est n bien conectados y utilizados La recolecci n de polvo puede reducir los peligros aso ciados al polvo...

Page 41: ...ientras funciona aumenta la posibili dad de descargas el ctricas resbalosos los mangos y superficies de agarre el op erario no podr trabajar con seguridad ni controlar la m quina en situaciones inespe...

Page 42: ...de giro En su interior se aloja un segundo tambor Este tambor interno permite reemplazar r pidamente un cable por otro impide que el cable se voltee en su interior y reduce la posibili dad de que agu...

Page 43: ...e el estado en que se encuentra una tuber a antes de proceder a limpiarla re comendamos una inspecci n visual de ella mediante una c mara El uso indebido de esta limpiadora de de sag es puede causarle...

Page 44: ...ha almacenado mojado o ha sido expuesto a fuertes sustancias qu micas Estas formas de desgaste o da o debilitan el cable haci ndolo m s susceptible a las torceduras y a romperse durante el funcionami...

Page 45: ...e nivelado y seco para situar al operario y la m quina No use la m quina parado sobre agua Si es necesario seque la zona donde trabajar haya una senda despejada y segura por donde ex tender el cord n...

Page 46: ...punta del cable Como regla general se recomienda ingresar primero con la herramienta de corte m s pe que a disponible para que el agua estancada em piece a fluir llevando consigo los desechos y trozo...

Page 47: ...que usted se resbale o sufra un choque el ctrico en espe cial si pisa superficies mojadas Respete las instrucciones de funcionamiento para evitar lesionarse con un cable que se dobla corta o da latig...

Page 48: ...mpujar el cable Operaci n asistida por la AUTOFEED Cerci rese de que por lo menos 30 cms 1 pie de cable se encuentran dentro del desag e y que la nariz del tambor est a no m s de 15 cms 6 pulgs del ac...

Page 49: ...los atascos y el desag e fluya libremente En muchas oportunidades es posible que no necesite hacer uso de las palancas de la AUTOFEED y pueda trabajar con la K 45 en forma manual solamente Si utiliza...

Page 50: ...lesiones Retraiga manualmente con sus manos enguantadas el resto del cable desde el interior del desag e y devu l valo al tambor de la limpiadora Si desea reemplace la he rramienta de corte en su punt...

Page 51: ...ble desen r llelo ntegramente antes de proceder Saque el nuevo cable de su envoltorio con sumo cuidado El cable viene tensado y puede golpear al usuario 3 Curve el nuevo cable entre 15 y 30 a unos 2 5...

Page 52: ...vado a una pulgada de su t rmino 4 Enrolle el cable en el tambor hacia la DERECHA en el sentido de las manecillas del reloj vea la Figura 16 Figura 16 Enrolle el cable dentro del tambor interior en el...

Page 53: ...aciones autorizado por RIDGID La m quina debe llevarse a servicentro independiente autorizado de RIDGID o ser devuelta a la f brica Para ubicar el Servicentro RIDGID m s cercano a su localidad o consu...

Page 54: ...P rdida a Tierra GFCI defectuoso Humedad en el motor interruptor o enchufe AUTOFEED cubierta de desechos AUTOFEED requiere lubricaci n Cable mal distribuido en el tambor No fuerce el cable Deje que l...

Page 55: ...dy s u ywane zgodnie z podr cznikiem u ytkownika spe niaj w a ciwe wymagania Dyrektyw i Stan dard w wymienione poni ej DECLARA O DE CONFORMIDADE CE Declaramos que as m quinas listadas acima quando uti...

Page 56: ...nsable de da o incidental o consiguiente alguno Relaci n entre la garant a y las leyes locales Algunos estados de los EE UU no permiten la exclusi n o restricci n referente a da os incidentales o cons...

Reviews: