Storage/Transportation
Storage
Transportation
Mainframe
-30
℃
to 40
℃
(22
o
F to 104
o
F) 15%
~
85%RH -30
℃
to 50
℃
(22
o
F to 122
o
F ) 15%
~
95%
Toner*
Under 50
℃
(122
o
F) 15%
~
80%RH Under
50
℃
(122
o
F )15%
~
80%RH
NOTE:
Remarks for Toner:
* Store in a dry, dark place where temperature does not exceed 45
℃
on continuance storage/transportation
conditions.
* Do not store more than 12 hours under the temperature between 41 and 50
℃
.
* Do not store more than a month under the temperature between 36 and 40
℃
.
* Do not store more than 2 years under the temperature between 10 and 32
℃
.
* Ideal temperature of toner use is between 10
℃
and 32
℃
*The definition of "Storage Period" : Starting from the timing of manufactured. The item must be unopened.
Parts / Special Tools / Maintenance
PM Parts / Yields
Mainframe
Unique/Common
U:
Unique for this model
C:
Common with listed model
*1PCU Service Ass’y M1322100
*2 Development section ass’y G1792303
*3 Transfer Unit ass’y G1793802
*4 Fusing Unit NA M1324102
Part Number
Description
Q’ty/
Unit
PM Interval
Unique or
Common
Around the drum
AD027012
*1
Charge Roller
1
160K
C (G147)
G7902329
*1
Brush Roller – Cleaning
1
160K
C (G147)
AD025021
*1
Pick-off
Pawl
2
160K
C
(G147)
D0092351
*1
Cleaning Blade
1
160K
C (G147)
D0099510
*1
OPC Drum
1
160K
C (G147)
Development
D0093086
*2
Development
Filter
1
160K
C
(G147)
B2969640
*2
Developer Black
1
320K
C (G147)
Transfer Belt Unit
A2323880
*3
Transfer
Belt
1
160K
C
(G147)
AD041135
*3
Cleaning Blade - Transfer Belt
1
320K
C (G147)
Fusing Unit
AE011132
*4
Hot Roller
1
160K
C (G147)
AE020199
*4
Pressure Roller
1
160K
C (G147)
AE044099
*4
Hot Roller Stripper
7
320K
C (G147)
D0094177
*4
Fusing Thermistor (Center and
End)
1 160K C
(G147)