background image

32DSSK03.B

 

1 - 2 

B. PRODUCT 

WARRANTY

 

 

RICON CORPORATION K-SERIES PRIVATE USE WHEELCHAIR LIFT 

 

FIVE-YEAR LIMITED WARRANTY 

Ricon Corporation (Ricon)

 warrants to the original purchaser of this product that Ricon will repair or replace, at 

its option, any parts that fail because of defective material or workmanship as follows: 

  Repair or replace parts for a period of one year from the date of purchase.  A complete list of parts covered 

by this warranty can be obtained from an authorized Ricon dealer. 

  Labor costs for specified parts replaced under this warranty for a period of one year from date put into ser-

vice.  A Ricon rate schedule determines parts covered and labor allowed. 

  Repair or replace lift powertrain parts for a period of five years from date of purchase.  A complete list of 

parts covered can be obtained from an authorized Ricon dealer or Ricon Product Support. 

If you need to return a product:

  Return this product to your installing dealer, or to Ricon, following the Ricon 

RMA procedure.  Please give as much advance notice as possible, and allow a reasonable amount of time for 
repair. 

This warranty does not cover:

 

  Labor or service charges. 

  Malfunction or damage to product parts caused by accident, misuse, lack of proper maintenance, neglect, 

improper adjustment, modification, alteration, the mechanical condition of the vehicle, road hazards, over-

loading, failure to follow operating instructions, or acts of nature (i.e., weather, lightning, flood).   

NOTE

:  Ricon recommends that this product be inspected by an authorized Ricon service technician at least 

once every six months, or sooner if necessary.  Required maintenance should be performed at that time. 

            

WARNING 

THIS PRODUCT HAS BEEN DESIGNED AND MANUFACTURED TO EXACT SPECIFICATIONS.  

~  ANY MODIFICATION OF THIS PRODUCT CAN BE HAZARDOUS  ~ 

This warranty is void If:

 

  The product has been installed or maintained by someone other than an authorized Ricon service techni-

cian. 

  The product has been modified or altered in any respect from its original design without written authoriza-

tion by Ricon. 

Ricon disclaims liability for any personal injury or property damage that results from operation of a Ricon 

product that has been modified from the original Ricon design.  No person or company is authorized to 

change the design of this Ricon product without written authorization by Ricon. 
Ricon's obligation under this warranty is exclusively limited to the repair or exchange of parts that fail within 

the applicable warranty period. 
Ricon assumes no responsibility for expenses or damages, including incidental or consequential damages.  

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusion may not apply. 
Important:  The warranty registration card must be completed and returned to Ricon within 20 days after in-

stallation of this Ricon product for the warranty to be valid.  The warranty is not transferable. 
The warranty gives specific legal rights.  There may be other rights that vary in each state. 

 

Summary of Contents for 32DSSK03

Page 1: ...PRINT K Series KlearVue DOT Private Use Lift OPERATOR MANUAL 08 02 05 32DSSK03 B 1995 2005RICONCORPORATION All Rights Reserved U S and Foreign Patents Pending Printed in the United States of America...

Page 2: ...OT Private Use Lift verifies that this plat form lift meets only the private use lift re quirements of FMVSS no 403 This lift may be installed on all vehicles appropriate for the size and weight of th...

Page 3: ...SION RECORD REV PAGES DESCRIPTION OF CHANGE ECO 1 1 2 2 2 9 Listed weight has changed to 600lbs 1 4 2 4 Changed pendant type to universal p n 14727 32DSSK03 B 3 3 Changed Max Load decal to 600lb 26183...

Page 4: ...INDICATORS 2 4 CONTROL PENDANT 2 4 CIRCUIT BREAKERS AND INDICATOR LIGHTS 2 5 BRIDGEPLATE LOAD SENSOR 2 6 THRESHOLD WARNING SYSTEM 2 7 MANUAL BACK UP PUMP 2 7 LIFT CYCLE COUNTER 2 8 E NORMAL LIFT OPER...

Page 5: ...32DSSK03 B iv This page intentionally left blank...

Page 6: ...manual backup pump If the lift loses power it can be raised or lowered manually A control pendant is used to unfold the platform out from the vehicle deploy The passenger boards the non skid platform...

Page 7: ...s of nature i e weather lightning flood NOTE Ricon recommends that this product be inspected by an authorized Ricon service technician at least once every six months or sooner if necessary Required ma...

Page 8: ...eration Exercise caution when operating lift to avoid injury and be certain that hands feet legs or clothing are not in path of the platform as it moves Read and thoroughly understand the operating in...

Page 9: ...STOW DEPLOY BASEPLATE PUMP HANDLE MANUAL BACKUP REAR POWER UNIT HYDRAULIC CYLINDER HYDRAULIC TOP AND BOTTOM ARMS RIGHT VERTICAL ARM ARMREST PLATFORM LINKAGE FOLDING HINGES PLATFORM ROLLSTOP FRONT FRON...

Page 10: ...age Front rollstop Front barrier prevents wheelchair from inadvertently rolling off of platform during platform movement Hydraulic cylinder left and right Telescoping single acting cylinders convert h...

Page 11: ...efer to Table 1 2 for the dimensions that correspond to your lift model TABLE 1 2 K SERIES OPERATING VOLUME DIMENSIONS inches mm s MODEL A B C K1203 30 762 51 1 295 30 762 K1205 32 813 51 1 295 30 762...

Page 12: ...t if unsafe conditions are present or unusual noises or movements are noticed Contact an authorized Ricon dealer for repair if necessary Read and comply with all warning labels and symbols affixed to...

Page 13: ...ng platform power chair users should turn off power and set brake Use great care in wet conditions because the wheelchair brakes are less effective if wheels or platform are wet Never leave platform o...

Page 14: ...lowers opens when platform reaches ground level UP Platform rises from ground level towards vehicle floor level The front rollstop automatically rises closes when platform leaves ground level STOW Pla...

Page 15: ...towards the ground Pushing the UP button causes the platform to rise towards floor level Pushing the STOW button when the platform is at floor level causes it to fold and retract into the vehicle Plat...

Page 16: ...ht is interfaced with the electrical system so that regardless of which interlock system is used the light will be on when the interlock provides power to lift and off when interlock has removed power...

Page 17: ...System Circuit Breaker is located on the hydraulic pump as sembly In the event of a short circuit in the control system the circuit breaker button will pop out If pressing and releasing button does no...

Page 18: ...argin of safety for lift users by warning them if the platform is below floor level The platform must be at floor level when boarding the platform prior to exiting the vehicle MANUAL BACK UP PUMP Refe...

Page 19: ...visible through a slot on the rear side The counter advances each time the platform moves through a complete cycle which consists of the platform moving from the vehicle floor to the ground and back t...

Page 20: ...ide space for lift operation and passenger boarding The lift operator must take special care to be certain that area is clear before deploying lift Be certain there are no obstacles beneath platform O...

Page 21: ...icle and lock wheelchair brakes CAUTION Do not stand on bridgeplate as platform lowers c LOWER PLATFORM Push and hold DOWN button until platform is at ground level and front rollstop is fully lowered...

Page 22: ...NG MANUAL BACKUP SYSTEM TO ENTER OR EXIT VEHICLE NOTE The threshold warning system is not active during manual operation and cannot be used to indicate platform height 1 DEPLOY PLATFORM a Refer to Fig...

Page 23: ...evel of interior floor turn valve clock wise to close do not over tighten valve Do not lower platform below vehicle floor level The rear edge of bridgeplate must rest flat on vehicle floor e Load Pass...

Page 24: ...ease wheelchair brakes and carefully exit platform 3 STOW PLATFORM a Refer to Figure 2 13 Verify that pump release valve is closed do not over tighten valve b Refer to Figure 2 14 Insert pump handle i...

Page 25: ...32DSSK03 B 2 14 This page intentionally left blank...

Page 26: ...areas where roads are salted in winter Verify that lift pivot points are clean and dry prior to lubrication C MAINTENANCE SCHEDULE Refer to cycle counter located on rear side of hydraulic power unit U...

Page 27: ...nd add fluid when platform is at ground level Fluid that is added when platform is raised will overflow when platform is lowered Hydraulic power unit Verify that pump hydraulic fluid level is at FULL...

Page 28: ...ground level Proceed to center of platform and face outward if possible LOCK WHEELCHAIR BRAKES Release wheelchair brakes and enter vehicle Press and hold UP button to raise platform to vehicle floor...

Page 29: ...32DSSK03 B 3 4 This page intentionally left blank...

Reviews: